840002 Volvo.Penta Hose attachment


840002 Hose attachment Volvo.Penta MD6; MD6A; MD6B Hose
840002 Hose attachment Volvo Penta
Rating:
53

Buy Hose attachment 840002 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$66.90
 

30-09-2024

US: Alpha Omega Machiner
Generic 840002 Brake Na Shoe for Clark
GENERIC Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || CL840002
$7.95
 

04-01-2024

US: Hartville Hardware
Hillman 840002 for Sale Sign with Space for Fill in, Red and White Plastic, 8x12 Inches 1-Sign
Hillman For Sale Sign helps post availability of a property for sale. The high contrast lettering ensures high visibility from a distance. Hillman For Sale Sign has For Sale text in bold white, and a white space for fill in against a reflective red background. || Sign made of ultra-violet fluorescent ink for maximum visibility from a distance. Measures 8 x 12 inches. || Made using high quality Styrene, a type of high strength plastic. Styrene is extremely durable, flexible, and tear resistant. Withstands most environments, and resists fading. || The sign can easily be installed on any surface with tape or nails. || Made in USA. This item is sold individually as a single pack, 1-Sign.
$63.71
 

28-10-2022

-: -
Aftermarket replacement 840002 Brake Na Shoe for Clark
Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || CL840002
Number on catalog scheme: 18
 

Compatible models:

MD6; MD6A; MD6B   Volvo.Penta

Volvo Penta entire parts catalog list:

Information:


Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service) , and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible mounting pads, the ground connection must be flexible to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Joints that are silver soldered and bolted are preferred.Neutral Connections
The generators with a Wye Configuration usually have the neutral ground when the generator is installed. Grounding the neutral is for preventing damage to equipment.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. Also, the excessive current will cause the generator voltage to collapse. The result depends on the following items: electrical characteristics of the generator , type of fault and trip rating of the circuit breaker. An undervoltage device may be required to provide an adequate short circuit protection.There are some cases when the neutral wire is not grounded. An ungrounded generator neutral lead is acceptable when the possibility of grounds to the phase leads has been eliminated. An example of such measures is ground fault protective circuits. Ground fault protection requires the entire group of distribution circuits to be treated as a system. The owner should contact a certified consultant if a new distribution system is being developed. The owner should also contact a certified consultant if an existing system should be modified for the ground fault protection.Single Units
Each unit should be connected to a common ground.In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.Be sure to check your local wiring codes.Connection Diagrams
The generator lead connections are located in the terminal box on the generator or in the enclosure for the control panel.Change the position of the wire terminals to modify the connection. The code for the winding is specified on the nameplate.Wiring Code A for Three-Phase Configuration
Illustration 1 g00952030
Illustration 2 g00952058
Factory connection for "A" wiring code
Table 1
L-L Voltage for Wiring Code A
Winding 50 Hz 60 Hz
6 190-208 190-240
7 220-230 -
8 - 190-208 R 230 voltage sensing - 0 => (T8) / 110 V => (T11)R 438 LS voltage sensing - 0 => (T3) / 220 V => (T2)Wiring Code B for Single-Phase Configuration or Three-Phase Configuration
Illustration 3 g00952097
Illustration 4 g00952196
Factory connection for "B" wiring code


Parts hose Volvo Penta:

185506
 
185506 Hose
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, A
185507
Hose
185507 Hose
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, A
941279
 
941279 Hose
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ175A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQ290A, D2-55; D2-
944075
 
944075 Hose
2001; 2001B; 2001AG, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
943471
 
943471 Hose clamp
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131
855129
 
855129 Hose connection
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200D; AQ200F; 280B,
185504
Hose
185504 Hose
AQ115A; AQ115B; AQ130, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D42A; D42A PP, MB10A, MD100A; TMD100A; TMD100AK, MD11; MD11C; MD11D, MD120A; MD120AK; TMD120A, MD1
801197
Hose attachment
801197 Hose attachment
AQ115A; AQ115B; AQ130, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
Back to top