897658 Volvo.Penta Housing


897658 Housing Volvo.Penta 230A; 230B; 250A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ23 Housing
897658 Housing Volvo Penta
Rating:
13

Buy Housing 897658 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$14.99

12-08-2024

CN: Helen Seeds
New Fresh 80pcs Green Amaranthus Plant Seeds
netechondra This package contains Seeds and We sale SEEDS ONLY, not plants. || Growth depends on soil and temperature. || Best for planting throughout the year. Best in class growing, Suitable for all Seasons, Fresh Seeds. || The seed grows a root to access water underground.the seed grows shoots that grow towards the sun. || If you have any issue with the item please contact us. We will try our best to resolve the issue as soon as possible.
Number on catalog scheme: 3
 

Volvo Penta entire parts catalog list:

230A; 230B; 250A; 250B
AD30A; AQAD30A; MD30A; TAMD30A; TMD30A; AD30; AQAD30; MD30; TAMD30; TMD30
AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
AQ120B; AQ125A; AQ140A; BB140A
AQ125B
AQ131A; AQ131B; AQ131C; AQ131D
AQ145A; BB145A
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C; AQ225D; AQ255A; AQ255B
AQ200D; AQ200F; 280B; 290A; 290DP
AQ225D; AQ225E; AQ225F; BB225A; BB225AV; BB225B; BB225C; 275; 280B; 290A; 290DP; MS3B; MS3C; MS4A
AQ231A; AQ231B; AQ231LB; 290A; DP-A; SP-A; 275A; 285A
AQ260A; AQ260B; BB260A; BB260AV; BB260B; BB260C
AQ271A; AQ271B; AQ271C; AQ271D; AQ271LB
AQ290A
MD21B; AQD21B
MD40A; TMD40A; TMD40B; TMD40C; AQD40A; TAMD40A; TAMD40B; AD40B; AQAD40A; AQAD40B

Information:


Table 1
Typical Voltage Of Electrical System During Cranking At Various Ambient Temperatures
Temperature 12 Volt System 24 Volt System
−23 to −7°C (−10 to 20°F) 6 to 8 volts 12 to 16 volts
−7 to 10°C (20 to 50°F) 7 to 9 volts 14 to 18 volts
10 to 27°C (50 to 80°F) 8 to 10 volts 16 to 24 volts Table 2 shows the maximum acceptable loss of voltage in the battery circuit. The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more.
Table 2
Maximum Acceptable Voltage Drop In The Starting Motor Circuit During Cranking
Circuit 12 Volt System 24 Volt System
Battery post "-" to the starting motor terminal "-" 0.7 volts 1.4 volts
Drop across the disconnect switch 0.5 volts 1.0 volts
Battery post "+" to the terminal of the starting motor solenoid "+" 0.5 volts 1.0 volts
Solenoid terminal "Bat" to the solenoid terminal "Mtr" 0.4 volts 0.8 volts Voltage drops that are greater than the amounts in Table 2 are caused most often by the following conditions:
Loose connections
Corroded connections
Faulty switch contactsDiagnosis Procedure
The procedures for diagnosing the starting motor are intended to help the technician determine if a starting motor needs to be replaced or repaired. The procedures are not intended to cover all possible problems and conditions. The procedures serve only as a guide.
If equipped with electric start, do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.Never turn the disconnect switch off while the engine is running. Serious damage to the electrical system can result.
If the starting motor does not crank or cranks slow, perform the following procedure:
Measure the voltage of the battery. Measure the voltage across the battery posts with the multimeter when you are cranking the engine or attempting to crank the engine. Do not measure the voltage across the cable post clamps.
If the voltage is equal to or greater than the voltage in Table 1, then go to Step 2.
The battery voltage is less than the voltage in Table 1. A low charge in a battery can be caused by several conditions.
Deterioration of the battery
A shorted starting motor
A faulty alternator
Loose drive belts
Current leakage in another part of the electrical system
Measure the current that is sent to the starting motor solenoid from the positive post of the battery. Note: If the following conditions exist, do not perform the test in Step 2 because the starting motor has a problem.
The voltage at the battery post is within 2 volts of the lowest value in the applicable temperature range of Table 1.
The large starting motor cables get hot.Use a suitable ammeter in order to measure the current. Place the jaws of the ammeter around the cable that is connected to the "bat" terminal. Refer to the Specifications Module, "Starting Motor" for the maximum current that is allowed for no load conditions.The current and the voltages that are specified in the Specifications Module are measured at a temperature of 27°C (80°F). When the temperature is below 27°C (80°F), the voltage will be lower through the starting motor. When the temperature is below 27°C (80°F), the current through the starting motor will be higher. If the current is too great, a problem exists in the starting motor. Repair the problem or replace the starting motor.If the current is within the specification, proceed to Step 3.
Measure the voltage of the starting motor.
Use the multimeter in order to measure the voltage of the starting motor, when you are cranking or attempting to crank the engine.
If the voltage is equal to or greater than the voltage that is given in Table 1, then the battery and the starting motor cable that goes to the starting motor are within specifications. Go to Step 5.
The starting motor voltage is less than the voltage specified in Table 1. The voltage drop between the battery and the starting motor is too great. Go to Step 4.
Measure the voltage.
Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with the voltage drops which are allowed in Table 2.
Voltage drops are equal to the voltage drops that are given in Table 2 or the voltage drops are less than the voltage drops that are given in Table 2. Go to Step 5 in order to check the engine.
The voltage drops are greater than the voltage drops that are given in Table 2. The faulty component should be repaired or replaced.
Rotate the crankshaft by hand in order to ensure that the crankshaft is not stuck. Check the oil viscosity and any external loads that could affect the engine rotation.
If the crankshaft is stuck or difficult to turn, repair the engine.
If the engine is not difficult to turn, go to Step 6.
Attempt to crank the starting motor.
The starting motor cranks slowly. Remove the starting motor for repair or replacement.
The starting motor does not crank. Check for the blocked engagement of the pinion gear and flywheel ring gear.Note: Blocked engagement and open solenoid contacts will give the same electrical symptoms.


Parts housing Volvo Penta:

943511
 
943511 Housing, protecting sleeve
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
941104
 
941104 Housing
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, A
838458
 
838458 Housing
AD30A; AQAD30A; MD30A, TAMD71A; TAMD72A
838336
 
838336 Housing
AD30A; AQAD30A; MD30A
958212
 
958212 Housing
430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ190A; AQ240A, AQ200B
851877
Housing
851877 Housing
AD30A; AQAD30A; MD30A, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200D; AQ200F; 280B, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B;
852194
 
852194 Housing
AD30A; AQAD30A; MD30A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, MD31A; TMD31A; TMD31B, MD40A; TMD40A; TMD40B, TMD41A; TMD41B; D41A
854051
 
854051 Housing
430; 430A; 430B, 500; 500A; 501A, 740A; BB740A, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ231A; AQ231B; AQ231LB, AQ271A; AQ271B; AQ271C, DP-C1; DP-D1; DP-S, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TMD41A; TMD41B; D41A, TMD41B; D41B; TAMD41B
Back to top