3801152 Volvo.Penta Injector, cyl 1


3801152 Injector, cyl 1 Volvo.Penta D3-110I-A; D3-110I-B; D3-110I-C Injector
3801152 Injector, cyl 1 Volvo Penta
Rating:
88

Buy Injector, cyl 1 3801152 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$81.00
 

28-03-2022

-: -
Main Bearing Set 3801152 for Cummins
Core:Main Bearings || Model and Application: 3801152 for Cummins || Characteristic:100% brand new, high quality, durable, value for money || Materials:  Metal || Other: Very good and trustworthy
$179.00
 

03-03-2022

-: -
Main Bearing Set 4025127 3801152 for Cummins .020
Part Number: 4025127, 3801152 || Applicable models: for Cummins .020 || Warranty: 1 Year. || TIPS: Please be sure to compare carefully with photos and check part number before buying items, If you are not sure this part is suitable, please feel free to contact us, we'll reply you as soon as possible. || Delivery Time: We will ship the item to you by DHL/FedEx/USPS, which will arrive in 5-9 days once we ship it to you. The delivery time will not a month like which shown online, you could buy with confidence!
$98.43
 

14-01-2023
15.0[6.75] Pounds
-: -
PantsSaver 3801152 Car Mat, Gray
Custom designed to fit YOUR car exactly! Install in seconds, no cutting or tools required || Features a patented Pants Saver Central Pan that holds and traps up to 500ml (16oz.) of water and keeps you and your vehicle's interior clean and dry || Lifetime warranty against cracking or breaking
Number on catalog scheme: 1
 

Compatible models:

Volvo Penta entire parts catalog list:

D3-110I-A; D3-110I-B; D3-110I-C; D3-130A-A; D3-130I-A; D3-130A-B; D3-130I-B; D3-130A-C; D3-130I-C; D3-160A-A; D3-160I-A; D3-160A-B; D3-160I-

Information:


Illustration 1 g00481278
System Schematic For Alarm Module (ALM)The alarm module (ALM) is available as an option. The ALM can be mounted on the instrument panel. The ALM can also be mounted at a distance as a remote annunciator. The ALM is used to satisfy requirements from customers and The National Fire Protection Association (NFPA) by annunciating the presence of a fault.The ALM communicates with the GSC by a serial data link. When the data link malfunctions, all of the indicators on the ALM that are controlled by the data link, flash at a rate of .5 Hz.Note: The maximum number of modules that can be connected to the serial data link is three. The maximum distance between a module and the GSC is 305 m (1000 ft). If these specifications are not met, there is a possibility for the ALM indicators to flash. Also, there is a possibility for the GSC to declare a diagnostic code of a CID 333. If the modules are not in compliance with the specifications, reduce the number of modules and/or shorten the distance to modules. Note: Faults are created when the harness connector (40 contact) is disconnected from the GSC during these troubleshooting procedures. Clear these created faults after the particular fault is corrected. In a properly operating system, when the harness connector is removed from the GSC, the following diagnostic codes are recorded.
CID 100 FMI 2 pressure sensor (engine oil)
CID 110 FMI 2 temperature sensor (engine coolant)
CID 111 FMI 3 fluid level sensor (engine coolant)
CID 190 FMI 3 speed sensor (engine)
CID 336 FMI 2 switch (engine control)
CID 590 FMI 9 engine ECMThe following condition is a possible cause of a CID 333 FMI 3.
A short to the "B+" of the signal for the data is present.The GSC treats this diagnostic code as an alarm fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: If a CID 333 FMI 3 is showing on the upper display and no alarm module is installed, check for a short. Check between the auxiliary terminal strip and the GSC.
Check the fault status (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Verify that a CID 333 FMI 3 is showing.
If the diagnostic code is not showing, enter the service mode and view the fault log (OP1). Verify that the diagnostic codes are showing. Expected Result: A CID 333 FMI 3 is showing as active or inactive. Results:
No - A CID 333 FMI 3 has not occurred (is NOT active and is NOT inactive). STOP.
Yes - A CID 333 FMI 3 is active. Proceed to 2.
Yes - A CID 333 FMI 3 is inactive. Proceed to 4.
Check the voltage of the signal for the data.
Turn the ECS to STOP.
At the ALM, measure the DC voltage from terminal 2 (positive meter lead) to terminal 7 (negative meter lead). Expected Result: The voltage that is measured should change constantly. The voltage should change within the range of 0 to 10 DCV. Results:
OK - Voltage measurement is correct. Proceed to 4.
NOT OK - Voltage measurement is NOT correct. Proceed to 3.
Check the voltage of the ALM and the GSC.
Turn the ECS to STOP.
At the ALM, remove wire (18) from terminal 2.
Disconnect the harness connector from the GSC.
At the ALM, measure the DC voltage from terminal 2 (positive meter lead) to terminal 7 (negative meter lead). The voltage should be 11.6 0.5 DCV.
At the GSC, measure the DC voltage from contact 35 of the GSC, to the ground ("B-") terminal of the relay module. The measured voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV.Expected Result: For 3.d, the voltage should be 11.6 0.5 DCV. For 3.e, the voltage should be changing constantly. The voltage should change within the range of 0 to 5.5 DCV.Results:
OK - Both voltage measurements are correct. Proceed to 4.
NOT OK - Voltage measured at the ALM is NOT correct. Replace the ALM. STOP.
NOT OK - Voltage measured at the GSC is NOT correct. Replace the GSC. STOP.
Check for a "B+" short in the harness.
Disconnect the harness connector from the GSC.
At the ALM, remove wire (18) from terminal 2.
Measure the resistance from wire (18) at the ALM to the battery ("B+") at the relay module.
Also, measure the resistance from wire (18) at the ALM to ground ("B-") at the relay module.Expected Result: For each measurement, the resistance should be greater than 20000 ohms. Results:
OK - Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". If the indicators on the ALM still flash after the inspection, replace the ALM. STOP.
NOT OK - One or both of the resistance measurements are less than 20000 ohms. The harness wiring with the incorrect resistance measurement is shorted. Troubleshoot and repair the faulty harness wiring between the ALM and the GSC. See the preceding System Schematic.


Parts injector Volvo Penta:

3801153
Injector, cyl 2
3801153 Injector, cyl 2
D3-110I-A; D3-110I-B; D3-110I-C
3801154
 
3801154 Injector, cyl 3
D3-110I-A; D3-110I-B; D3-110I-C
3801155
 
3801155 Injector, cyl 4
D3-110I-A; D3-110I-B; D3-110I-C
3801156
 
3801156 Injector, cyl 5
D3-110I-A; D3-110I-B; D3-110I-C
3801259
 
3801259 Injector
D3-110I-A; D3-110I-B; D3-110I-C
3801260
Injector
3801260 Injector
D3-110I-A; D3-110I-B; D3-110I-C
Back to top