821641 Volvo.Penta Inlet manifold


821641 Inlet manifold Volvo.Penta MD70B; MD70BK; TMD70B Inlet
821641 Inlet manifold Volvo Penta
Rating:
103

Buy Inlet manifold 821641 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$56.18
 

09-07-2023

-: -
Aftermarket replacement Water Pump Rebuild Kit for YZ125 05 06 07 08 09 10 11-18
Water Pump Rebuild Kit for YZ125 05 06 07 08 09 10 11-18 || Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || 821641
$34.89
 

09-07-2023

-: -
Vertex Water Pump Rebuild Kit 821641
Includes inner clutch cover gasket, water pump cover gasket and all bearings, seals and washers required to rebuild water pump
$375.21
 

31-01-2023

-: -
Technical Precision Replacement for EZGO/Cushman/TEXTRON 821641 Battery
Replacement For EZGO / CUSHMAN / TEXTRON 821641 || Unit per sale:1
Number on catalog scheme: 9
 

Compatible models:

Volvo Penta entire parts catalog list:

MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B

Information:


Illustration 1 g03658518
Diagram of the air/fuel ratio control
Required Inputs from the Customer
to control the air/fuel ratio, the control system depends on these inputs from the customer:
Fuel Quality
Engine LoadFuel Quality
Before the initial start-up, a current gas analysis is required. Periodic gas analyses are also recommended.Data from the gas analysis must be entered into Caterpillar Software, LERW4485, "Gas Engine Rating Pro (GERP)". The results are programmed into the ECM.Note: Is important to use the Caterpillar Software, LERW4485, "Gas Engine Rating Pro (GERP)". Use of only the data from the gas analysis can result in incorrect settings.The ECM must have values for the following parameters. The values are entered via the "Configuration" screen of Cat ET:
"Fuel Quality Input Type Configuration"
"Fuel Quality"
"Fuel Quality Sensor LHV Lower Setpoint"
"Fuel Quality Sensor LHV Upper Setpoint"
"Gas Specific Gravity"
"Fuel Specific Heat Ratio"The "Fuel Quality Input Type Configuration" parameter setting will be determined by the consistency of the fuel supply.Select "Configuration" for engines that run on a consistent fuel supply.Select "4-20 mA" for engines that utilize a 4-20 mA signal from a fuel quality sensor due to an inconsistent fuel supply.The following parameter is used only when the "Fuel Quality Input Type Configuration" is set to "Configuration":
Fuel QualityA fixed LHV will be entered in the "Fuel Quality" parameter for engines that run on a consistent fuel supply.The ECM uses the LHV to help determine the fuel command to the fuel metering valve.The fuel command is sent to the fuel metering valve via the CAN data link.The following parameters are used only when the "Fuel Quality Input Type Configuration" is set to "4-20 mA":
Fuel Quality Sensor LHV Lower Setpoint
Fuel Quality Sensor LHV Upper SetpointThe ECM provides the following information to the fuel metering valve via the CAN data link:
"Fuel Specific Heat Ratio"
"Gas Specific Gravity"Note: For more details on these parameters, refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Engine Load
The ECM must have values for the following parameters. The values are entered via the "Configuration" screen of Cat ET:
"Engine Driven Accessory Load Configuration"
"Generator Efficiency"Note: For more details on these parameters, refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Mode of Operation
The air/fuel ratio control has two basic modes of operation:
Open loop
NOX feedbackThe mode of operation is determined by the "Emissions Feedback Mode Configuration" parameter. Cat ET is used to change the mode of operation.Select "Disable" to activate the open loop mode.Select "Enable" to activate the feedback mode.Open Loop Mode
The open loop mode of operation uses no feedback.During operation in this mode, the ECM controls the air/fuel ratio with maps and with calculations for the desired air/fuel ratio.The air/fuel ratio is controlled in the open loop mode from start-up until the engine load becomes greater than 40 percent. Above 40 percent the engine operates in feedback mode. When operating in feedback mode, the engine load must be dropped below 25 percent for the control system to switch to open loop mode.The ECM uses a Fuel Correction Factor (FCF) to help determine the fuel command to the fuel metering valve. During operation in the open loop mode, the FCF is always 100 percent.The ECM uses the LHV to help determine the fuel command to the fuel metering valve.The LHV can be varied in the customer programmable "Fuel Quality" parameter to affect the air/fuel ratio.Refer to Systems Operation/Testing and Adjusting, "Air/Fuel Ratio Control - Adjust" .NOx Feedback
During operation in the feedback mode, the ECM continues to calculate the desired air/fuel ratio. The result is still used to calculate the fuel command.The ECM uses the following to calculate the desired NOX factor.
"Desired Engine Exhaust NOx Level Setting"
Engine load
Engine speed
The measured NOX level in the exhaust.Exhaust NOX concentration is communicated to the ECM from the NOX sensor via the CAN data link.The customer programmable "Desired Engine Exhaust NOx Level Setting" can be varied to affect the air/fuel ratio.Note: This configurable feature is only available with the Non-EPA certified arrangementThe calculation for the desired NOX level is used to adjust the FCF.Because some of the factors for calculating the desired NOX level will vary during operation, the FCF will also vary during operation.The ECM determines the fuel command to the fuel metering valve. The command is sent to the fuel metering valve via the CAN data link.Refer to Systems Operation/Testing and Adjusting, "Air/Fuel Ratio Control - Adjust" .


Parts inlet Volvo Penta:

837250
 
837250 Inlet manifold
AQD70D; TAMD70D; TAMD70E, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
421016
Inlet valve
421016 Inlet valve
D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
821640
 
821640 Inlet manifold
MD70B; MD70BK; TMD70B
466274
Inlet manifold
466274 Inlet manifold
D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
836204
 
836204 Inlet manifold
D70B; D70B PP; D70B K, MD70B; MD70BK; TMD70B
821639
 
821639 Inlet manifold
D70CHC; D70CRC; TD70CHC, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
836349
 
836349 Inlet manifold
MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
Back to top