832682 Intermediate housing Volvo.Penta
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A
Intermediate
Price: query
Rating:
Compatible models:
Volvo Penta entire parts catalog list:
AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
- Intermediate Housing AQ Drive Unit 270
- Intermediate Housing AQ Drive Unit 270T
- Intermediate Housing AQ Drive Unit 280
- Intermediate Housing AQ Drive Unit 280T
AQ125B
AQ131A; AQ131B; AQ131C; AQ131D
AQ145A; BB145A
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C; AQ225D; AQ255A; AQ255B
AQ200D; AQ200F; 280B; 290A; 290DP
AQ225D; AQ225E; AQ225F; BB225A; BB225AV; BB225B; BB225C; 275; 280B; 290A; 290DP; MS3B; MS3C; MS4A
- Intermediate Housing: DRIVE 275
- Intermediate Housing: DRIVE 275A
- Intermediate Housing: DRIVE 280
- Intermediate Housing: DRIVE 280L
- Intermediate Housing: DRIVE 275
- Intermediate Housing: DRIVE 275A
- Intermediate Housing: DRIVE 280
- Intermediate Housing: DRIVE 280L
MD21B; AQD21B
MD40A; TMD40A; TMD40B; TMD40C; AQD40A; TAMD40A; TAMD40B; AD40B; AQAD40A; AQAD40B
Information:
Table 1
Module Identifiers    
MID    Description    
36     Electronic Control Module (ECM) for the engine    
105     Hydraulic Pump Control    
106     Electrohydraulic Control Module    Component Identifier (CID) - The CID is a number with three or four digits. The CID indicates the component that generated the code. For example, the CID number 17 identifies the fuel shutoff valve.Failure Mode Identifier (FMI) - The FMI is a two digit code that indicates the type of failure. Table 2 is a list of the failure mode identifiers.
Table 2
Failure Mode Identifiers    
FMI    Description    
00     The data is valid, but the data is above the normal range of operation.    
01     The data is valid, but the data is below the normal range of operation.    
02     The data is erratic, intermittent, or incorrect.    
03     The voltage is above normal or shorted high.    
04     The voltage is below normal or shorted low.    
05     The current is below normal or the circuit is open.    
06     The current is above normal or the circuit is grounded.    
07     The mechanical system is not responding correctly.    
08     There is a frequency, a pulse width, or a period that is abnormal.    
09     There has been an abnormal update.    
10     There has been an abnormal rate of change.    
11     The failure mode is not identifiable.    
12     The device or the component is faulty.    
13     The device or the component is out of calibration.    
14-31     Reserved    Note: Do not confuse diagnostic codes with event codes. For information on event codes, see Troubleshooting, "Event Codes".Active Diagnostic Codes
An active diagnostic code represents a problem with the electronic control system. Correct the problem as soon as possible.When an active diagnostic code is generated, a warning may be displayed on an electronic display such as the Caterpillar Monitoring System.Logged Diagnostic Codes
When the ECM generates a diagnostic code, the ECM logs the code in permanent memory. The ECM has an internal diagnostic clock. The ECM will record the following information when a code is generated:
Hour of the first occurrence of the code
Hour of the last occurrence of the code
Number of occurrences of the codeThis information is a valuable indicator for troubleshooting intermittent problems. Any logged diagnostic codes will automatically be deleted if no additional occurrences are recorded in 100 hours. Some diagnostic codes may be easily triggered. Some diagnostic codes may log occurrences that did not result in complaints. The most likely cause of an intermittent problem is a faulty connection or damaged wiring. The next likely cause is a component failure. The least likely cause is the failure of the ECM. Diagnostic codes that are logged repeatedly may indicate a problem that needs special investigation.If the symptoms continue, use the proper procedure for troubleshooting the symptoms that have been experienced by the operator.Note: Always clear logged diagnostic codes after investigating and correcting the problem which generated the code.
Parts intermediate Volvo Penta:
844297
844297 Intermediate ring
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, MD40A; TMD40A; TMD40B, TD30A; TD31ACE; TD40A
834803
834803 Intermediate bearing
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, MD21B; AQD21B, MD31A; TMD31A; TMD31B, MD40A; TMD40A; TMD40B, TD30A; TD31ACE; TD40A, TMD41A; TMD41B; D41A
852363
852363 Intermediate lever
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, MD11; MD11C; MD11D, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B;
832131
832131 Intermediate ring
AQ115A; AQ115B; AQ130, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
832132
832132 Intermediate ring
AQ115A; AQ115B; AQ130, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
832133
832133 Intermediate ring
AQ115A; AQ115B; AQ130, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
815005
834530