22347448 Volvo.Penta Level sight glass


22347448 Level sight glass Volvo.Penta TAD1640GE; TAD1641GE; TAD1642GE, TWD1672GE; TWD1673GE; TWD1672-1673GE Level

Buy Level sight glass 22347448 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 11
 

Volvo Penta entire parts catalog list:

TAD1640GE; TAD1641GE; TAD1642GE; TAD1650GE; TAD1651GE; TWD1643GE; TWD1652GE; TWD1653GE; TWD1663GE
TWD1672GE; TWD1673GE; TWD1672-1673GE

Information:


Illustration 1 g06402479
Left Side View
(1) Fuel Transfer Pump
(2) Vibration Damper
(3) Primary Fuel Filter Base
(4) Breather
(5) Open Crankcase Ventilation (OCV) Filter
(6) Mixing Manifold
(7) Engine Throttle Valve
(8) Fuel Metering Valve
(9) Electronic Control Module (ECM)
(10) Flywheel Housing
(11) Oil Pan
(12) Oil Level Gauge
Illustration 2 g06402488
Right side view
(13) Secondary Fuel Filter
(14) Exhaust Manifold
(15) Aftertreatment Hydrocarbon Doser
(16) Turbocharger
(17) Compressor Housing
(18) Temperature Regulator Housing
(19) Water Pump
(20) Oil Pump
(21) Oil Filter
(22) Oil Filter BaseThe C13 engine is in-line six cylinder arrangements. The engine has a bore of 130 mm (5.12 inch) and a stroke of 157 mm (6.18 inch). The displacement of the engine is 12.5 L (763 cu in). Each cylinder has two inlet valves and two exhaust valves. The firing sequence of the engine is 1-5-3-6-2-4.The Mechanical Electronic Unit Injector (MEUI) provides increased control of the timing and increased control of the fuel air mixture. Engine rpm is controlled by adjusting the injection duration. Engine timing is controlled by the precise control of fuel injection timing.The Electronic Control Module (ECM) monitors the components of the engine during operation. In the event of a component failure, the operator will be alerted to the condition by the use of an amber warning lamp and an event code will be logged in the ECM. Cat® Electronic Technician (ET) can be connected to the engine to read any logged faults.Starting The Engine
The engines ECM will automatically provide the correct amount of fuel to start the engine. Do not hold the throttle down while the engine is cranking. If the engine fails to start in 30 seconds, release the starting switch. Allow the starting motor to cool for 2 minutes before the starting motor is used again.
Excessive ether (starting fluid) can cause piston and ring damage. Use ether for cold weather starting purposes only.
Cold Mode Operation
Starting the engine and operation in cold weather depends on the type of fuel used, the oil viscosity, and other optional starting aids. For more information, refer to the Operation and Maintenance Manual, "Cold-Weather Operation".The Cold Mode flag in Caterpillar Electronic Technician (ET) indicates that the engine system is compensating with a cold mode strategy.Some examples of a cold mode strategy may include:
Elevated RPM
Timing enhancements
Fuel injection enhancementsTroubleshooting performance-related problems with the Cold Mode flag active is not recommended.The Cold Mode flag will activate when the coolant temperature is 35° C (95° F).Once coolant temperature is above 75° C (167° F), the cold mode strategy will not be active.Customer Specified Parameters
The engine can be programmed for several customer specified parameters. For a brief explanation of each of the customer specified parameters, see the Operation and Maintenance Manual.Delayed Engine Shutdown (If Equipped)
The "Delayed Engine Shutdown" strategy allows the engine to run for a time after the engine start switch key is turned to the OFF position to cool the engine and system components. The engine start switch key may be removed.Note: There may be regulations that define the requirements for the operator and/or support personnel to be present when the engine is running.Note: The DEF purge process will run for 2 minutes once the engine is shut down and must complete. The purge process may occur during "Delayed Engine Shutdown". It is important not to turn the battery disconnect switch OFF during the purge process. Do not turn the battery power disconnect switch OFF until battery disconnect switch indicator lamp has turned OFF. If the purge process does not complete, a diagnostic code will become active.
Leaving the machine unattended when the engine is running may result in personal injury or death. Before leaving the machine operator station, neutralize the travel controls, lower the work tools to the ground and deactivate all work tools, and place the lever for the hydraulic lockout control in the LOCKED position.
Note: Leaving the engine unattended while running may result in property damage in the event of a malfunction.Delayed Engine Shutdown Lamp
Illustration 3 g03572624The Delayed Engine Shutdown strategy will run whenever the DPF outlet temperature is above a threshold at engine shutdown. The temperature needs to drop below that threshold before Delayed Engine Shutdown will end. There is a parameter in Cat ET, "Delayed Engine Shutdown Aftertreatment Outlet Gas Temperature Threshold" which can be configured between 200° C (392° F) and 575° C (1067° F). The default setting is engine iron set or application specific and originally set by the product group. Only an authorized dealer using passwords through Caterpillar's Feature Protection System (FPS) can change the threshold. When the estimated DPF outlet temperature drops below the programmed value, the DES will end and the engine will shut down. There is also a "Delayed Engine Shutdown Maximum Time" parameter in Cat ET. This will shut down DES once the threshold time is met regardless if it has dropped below the temperature threshold. The minimum time it can be set to is 7 minutes (default) for machine engine customers and 4 minutes for commercial engine customers. The maximum time it can be set to is 30 minutes. Once programmed in the factory the time can only be increased with FPS by an authorized dealer. (that is, if it comes programmed at 20 minutes, a dealer can only increase it up to 30, cannot lower it below 20). Once Delayed Engine Shutdown begins, it will always run for a minimum of 76 seconds even if temperature drops below threshold before that.When the engine start switch key is turned to the OFF position and delayed engine shutdown is active, the "Delayed Engine Shutdown" lamp will illuminate and/or the following text will be displayed on the dash: Engine Cooldown Active.Note: There is either a STOP (1) orDELAYED ENGINE SHUTDOWN (1A) position on the key switch. To override delayed engine shutdown and stop the engine, turn the engine start switch key to the STOP (1) or DELAYED ENGINE SHUTDOWN (1A) position. Overriding the delayed engine shutdown may reduce engine and system component life. A warning message and/or audible alarm will be initiated and a fault code will be logged for improper engine shutdown.
Illustration 4 g03740759


Parts level Volvo Penta:

21596913
 
21596913 Level sensor
TAD1640GE; TAD1641GE; TAD1642GE
21876315
 
21876315 Level sensor
TAD1640GE; TAD1641GE; TAD1642GE, TWD1672GE; TWD1673GE; TWD1672-1673GE
Back to top