241782 Volvo.Penta Lever


241782 Lever Volvo.Penta AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D70B; D70B PP; D70B K, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD61A; TAMD62A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TD1 Lever
241782 Lever Volvo Penta
Rating:
43

Buy Lever 241782 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$74.99
 

19-08-2020

-: -
Miller 241782 Bushing, 1.000In Taper Lock
$50.93
 

21-11-2023
0.4[0.18] Pounds
-: -
American Shifter 241782 Red Flame Metal Flake Shift Knob with M16 x 1.5 Insert (Blue Eagle with Arrow)
Number on catalog scheme: 23
 

Volvo Penta entire parts catalog list:

AQD70D; TAMD70D; TAMD70E
D100A; D100AK; D100B; TD100A; TD100AG; TD100AK
D70B; D70B PP; D70B K; TD70B
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
TAMD122A; TMD122A; TAMD122P-A; TAMD122P-B; TAMD122P-C; TMD122A/C; TAMD122AF
TAMD162A; TAMD162B; TAMD162C; TAMD162C-B
TAMD61A; TAMD62A
TAMD71A; TAMD72A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TD100G-87; TD1030ME; TWD1030ME
TD70G; TD70G-83; TD70GPP; TD70GPP-83; TID70G; TID70GPP; TID70GG; TD70GG; TD70GG-83
TMD121C; TAMD121C; TAMD121D; TAMD122C; TAMD122D

Information:

Probable Causes
Fuel injector O-ring seals
Fuel injector tip
Fuel transfer pump seal
High-pressure fuel pump
Cracked cylinder headRecommended Actions
Complete the procedure in the order in which the steps are listed.
Table 1
Troubleshooting Test Steps     Values     Results    
1. Leaking Seals
A. Remove the injector from the affected cylinder and visually inspect the injector O-ring seals for damage.
If leakage is found and the O-rings are in good repair, there may be a problem with the injector. Replace the injector. Ensure that the new trim files are installed. Refer to Troubleshooting, "Injector Trim File - Install" for details. Use Caterpillar Electronic Technician (ET) to perform a "Fuel System Verification Test". Refer to Troubleshooting, "Injector Solenoid - Test" for details.
If the leakage is not located, add the appropriate dye to the fuel tanks. Run the engine at high idle for several minutes. Shut down the engine and remove the valve covers. Use a black light to check for traces of dye around each injector.
   
O-ring Seal    
Result: The injector O-ring seal is damaged.
Repair: Replace the damaged seals. Install the injector onto the engine and confirm that the repair has resolved the problem.
Result: The injector O-ring seal is not damaged.
Proceed to Test Step 2.    
2. Fuel Injector Tip
A. Use Cat ET to perform the "Cylinder Cutout Test" in order to identify any cylinders that may be overfueled.
B. A fuel injector tip that is broken or fractured is a possible cause of a cylinder that is being overfueled. If a cylinder is identified by the test, Remove the injector and check the injector tip for damage. Check the fuel injector tip for cracks or breakage.
   
Injector Tip    
Result: The fuel injector tip is damaged.
Repair: Replace the suspect injector.
Result: The fuel injector tip is not damaged.
Proceed to Test Step 3.
   
3. Fuel Transfer Pump Seal
A. Check for fuel leakage around the shaft seal for the fuel transfer pump. Ensure that the weep hole is not plugged.
   
Pump Seal    
Result: There is fuel leakage around the shaft seal.
Repair: Replace the fuel transfer pump.
Result There is not fuel leakage around the shaft seal.
Proceed to Test Step 4.
   
4. High-pressure fuel pump
A. Remove the plug from the bottom of the high-pressure fuel pump. Remove the plug from the bottom of the fuel pump adapter. Expect that a small amount of engine oil will drain from the openings.
B. Use the manual override for the fuel priming pump to run the pump in order to pressurize the fuel system. Allow the pump to run for at least 5 minutes while you monitor the drain holes in the pump and the adapter for leakage.
   
Defective Pump    
Result A leak is detected.
Repair: Replace the high-pressure fuel pump.
Result No leak is detected.
Proceed to Test Step 5.
   
5. Cracked Cylinder Head
A. Look for signs of damage to the internal passages for the fuel supply to the injectors in the cylinder head. Check for pin hole leaks. Refer to Disassembly and Assembly.
   
Cracked Head    
Result The internal passages for the fuel supply to the injectors are damaged.
Repair: Repair or replace the cylinder head.
   


Parts lever Volvo Penta:

852988
Lever
852988 Lever
2001; 2001B; 2001AG, AQD70D; TAMD70D; TAMD70E, D70CHC; D70CRC; TD70CHC, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60C, TMD41A; TMD41B; D41A, TMD41B; D41B; TAMD41B
825882
Lever
825882 Lever
AQ115A; AQ115B; AQ130, AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C
846543
 
846543 Lever
D100A; D100AK; D100B, MD120A; MD120AK; TMD120A, TD120HP-86; TD121; TD121G, TID120FPP; TID120FG; TD120G, TID121FG, TMD100C
845008
 
845008 Lever
D70CHC; D70CRC; TD70CHC, MD70C; TMD70C; TAMD70C, TAD1230P; TD121GP-87; TWD1210P, TAMD122A; TMD122A; TAMD122P-A, TAMD60C, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TD100CHC; TD100CRC; TD121CHC, TD100G-87
240060
Lever
240060 Lever
D100A; D100AK; D100B, MD70C; TMD70C; TAMD70C, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD74A; TAMD74A-A; TAMD74A-B, TD100CHC; TD100CRC; TD121CHC, TD100G-87; TD1030ME;
423471
Lever
423471 Lever
D120A; D120AK; TD120A, TAMD122A; TMD122A; TAMD122P-A, TD100CHC; TD100CRC; TD121CHC, TD120AHC; TD120ARC; TAD120AHC, TID120FPP; TID120FG; TD120G
815501
 
815501 Lever
D100A; D100AK; D100B, TD100G; TD100G-85; TD100G-87
31309
 
31309 Lever
D100A; D100AK; D100B
Back to top