11996307 Volvo.Penta O-ring


11996307 O-ring Volvo.Penta TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD164KAE, TWD1230ME O
11996307 O-ring Volvo Penta
Rating:
33

Buy O-ring 11996307 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

Volvo Penta entire parts catalog list:

TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P; TAMD165A-A; TAMD165C-A; TAMD165P-A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TAMD74A; TAMD74A-A; TAMD74A-B; TAMD74C-A; TAMD74C-B; TAMD74L-A; TAMD74L-B; TAMD74P-A; TAMD74P-B; TAMD75P-A
TD164KAE
TWD1230ME

Information:


Illustration 1 g00601694Note: Push in the button (1) on the latching type solenoid in order to manually shut off the engine. The solenoid cannot be manually latched in the run position for starting. 155-4651 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.39 0.04 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 2.58 0.30 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 155-4652 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.55 1.60 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 10.3 1.0 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Energize-To-Run (ETR) Nonlatching Type
Illustration 2 g00602191 125-5771 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.29 0.03 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 12.0 1.2 ohmsHold in force ... 4.8 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 14.4 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 125-5772 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.15 1.10 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 48.0 4.8 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Wiring Connections For Fuel Shutoff Solenoid
Energize-To-Shutoff (ETS) Latching Type
Illustration 3 g00602209
End view of ETS solenoid
(1) Ground terminal Ground wire size ... 10 gauge (2) Stop terminal Wire size to OFF terminal of keyswitch ... 16 gauge (3) Start terminal Wire size to S (switch) terminal of starter motor ... 10 gaugeEnergize-To-Run (ETR) Nonlatching Type
Illustration 4 g00602232
End view of ETR solenoid
The solenoid that has two wires has no polarity requirements for the wires.


Parts o Volvo Penta:

955974
O-ring
955974 O-ring
120S-A; 120S-B; 120S-D, 130S-C; 130SR-C, 150S-C; 150SR-C, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41
925256
O-ring
925256 O-ring
120S-A; 120S-B; 120S-D, 130S-C; 130SR-C, 130S; 130S-B; 130SR-A, 150S-C; 150SR-C, 150S; 150S-B; 150SR, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5.8FiPMDA, 5.0FIPNCACE; 5
955981
O-ring
955981 O-ring
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, DP-SM; DP-SM 1.68; DP-SM 1.78, DPX-A; TSK DPX-A, DPX-R; DPX-R 1.47; DPX-R 1.51, DPX-S; DPX-S1; DPX-S 1.59, KAD32P; TAMD42WJ-A; KAD4
925069
O-ring
925069 O-ring
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH;
967344
O-ring
967344 O-ring
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, DP-SM; DP-SM 1.68; DP-SM 1.78, IPS15-A, IPS15-B, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1
3581070
O-ring
3581070 O-ring
AD31L-A; AD31P-A; AD41L-A, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, D3-110I-A; D3-110I-B; D3-110I-C, D8A1-A MP; D8A2-A MP, D9A2A; D9A2A D9-425; D9A2A D9-500, KAD32P; TAMD42W
976044
O-ring
976044 O-ring
AD31L-A; AD31P-A; AD41L-A, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B
949656
O-ring
949656 O-ring
1372, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E M
Back to top