958228 O-ring Volvo.Penta
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MD31A; TMD31B; TAMD31B, MD70B; MD70BK; TMD70B
O
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Center Paddock Stand CS Power Evo compatible with Suzuki GSX-R 1000 05-08 red
ConStands The perfect solution for any work on the motorcycle - maintenance, care, tire replacement, repairs. Easy to move, stable double casters (included) for easy maneuvering in the garage, in the basement or on the race track || Specifications. Weight: 17 kg (casters incl.). Load capacity: 300 kg. The max. ground clearance of the wheels is 5-15cm, depending on the model. Can be dismantled with little effort for transport and storage. Perfectly suitable for hibernation, tire and f || Easy operation thanks to internal slide rails. Self-locking height adjustment and can be locked in different working heights || Adapter and mounting plate for the respective model inclusive. Adapters can be purchased separately independently of the base stand in case of a model change or when used on more than one bike || Accessories such as crash bars or modified footrests can cause that the stand cannot be used. Please check before purchase.
ConStands The perfect solution for any work on the motorcycle - maintenance, care, tire replacement, repairs. Easy to move, stable double casters (included) for easy maneuvering in the garage, in the basement or on the race track || Specifications. Weight: 17 kg (casters incl.). Load capacity: 300 kg. The max. ground clearance of the wheels is 5-15cm, depending on the model. Can be dismantled with little effort for transport and storage. Perfectly suitable for hibernation, tire and f || Easy operation thanks to internal slide rails. Self-locking height adjustment and can be locked in different working heights || Adapter and mounting plate for the respective model inclusive. Adapters can be purchased separately independently of the base stand in case of a model change or when used on more than one bike || Accessories such as crash bars or modified footrests can cause that the stand cannot be used. Please check before purchase.
Compatible models:
Volvo Penta entire parts catalog list:
- Induction and Exhaust Manifold: B » 958228
AD41D; D41D; TAMD41D; TMD41D; HS1A
AQD70D; TAMD70D; TAMD70E
KAD32P; TAMD42WJ-A; KAD43P-A; KAMD43P; KAMD43P-A; KAMD43P-B; KAD44P; KAD44P-B; KAD44P-C; KAMD44P-A; KAMD44P-C; KAD300-A; KAMD300-A; HS1A; HS1E
- Induction and Exhaust Manifold
- Induction and Exhaust Manifold: C
- Induction and Exhaust Manifold: B
- Induction and Exhaust Manifold: B
KAD42B; KAMD42B; TAMD42B
KAD42P-A; KAMD42P-A; HS1A
MD31A; TMD31B; TAMD31B; AD31B
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
TMD41B; D41B; TAMD41B; AD41B; AD41BJ
Information:
Drain the Cooling System
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Ensure that the engine will not start when the cooling system is drained.
Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap.
Illustration 1 g00750410
(1) Coolant drain
Illustration 2 g00750411
Locations of the cooling system drain plugs
(1) Oil cooler
(2) Jacket water pump
(3) Engine block Note: If the engine has a jacket water heater, drain the coolant from the heater.
Open the coolant drain. Remove the cooling system drain plugs. Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tools Group:Outside U.S.A. (309) 675-6277
Inside U.S.A. 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
CSTG COSA Geneva, Switzerland 41-22-849 40 56
Clean the Cooling System
Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the cooling system drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 30 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Open the coolant drain. Remove the cooling system drain plugs. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs. Open the water inlet for the separate circuit aftercooler (if equipped). Cleaning a Cooling System that has Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be an active flow through the cooling system components.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 90 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Open the coolant drain. Remove the cooling system drain plugs. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the cooling system drain. Clean the cooling system drain plugs and install the cooling system drain plugs. Fill the Cooling System
Note: For information about the proper coolant to use, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section). For the capacity of the cooling system, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with coolant/antifreeze. After filling the cooling system, do not install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine in order to purge the air from the cavities of the engine block. Allow the coolant to warm and allow the coolant level to stabilize. Stop the engine.
Check the coolant level. Maintain the coolant to the proper level on the sight gauge (if equipped). If a sight gauge is not equipped, maintain the coolant within 13 mm (.5 inch) below the bottom of the filler pipe.
Clean the radiator filler cap. Inspect the
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Ensure that the engine will not start when the cooling system is drained.
Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap.
Illustration 1 g00750410
(1) Coolant drain
Illustration 2 g00750411
Locations of the cooling system drain plugs
(1) Oil cooler
(2) Jacket water pump
(3) Engine block Note: If the engine has a jacket water heater, drain the coolant from the heater.
Open the coolant drain. Remove the cooling system drain plugs. Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tools Group:Outside U.S.A. (309) 675-6277
Inside U.S.A. 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
CSTG COSA Geneva, Switzerland 41-22-849 40 56
Clean the Cooling System
Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the cooling system drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 30 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Open the coolant drain. Remove the cooling system drain plugs. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs. Open the water inlet for the separate circuit aftercooler (if equipped). Cleaning a Cooling System that has Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be an active flow through the cooling system components.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 90 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Open the coolant drain. Remove the cooling system drain plugs. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the cooling system drain. Clean the cooling system drain plugs and install the cooling system drain plugs. Fill the Cooling System
Note: For information about the proper coolant to use, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section). For the capacity of the cooling system, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with coolant/antifreeze. After filling the cooling system, do not install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine in order to purge the air from the cavities of the engine block. Allow the coolant to warm and allow the coolant level to stabilize. Stop the engine.
Check the coolant level. Maintain the coolant to the proper level on the sight gauge (if equipped). If a sight gauge is not equipped, maintain the coolant within 13 mm (.5 inch) below the bottom of the filler pipe.
Clean the radiator filler cap. Inspect the
Parts o Volvo Penta:
925064
925064 O-ring
2001; 2001B; 2001AG, 230A; 230B; 250A, 430; 430A; 430B, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5.8FiPMDA, 5.0FIPNCACE; 5.0FIPNCBCE; 5.0FIPNCMCE, 5.0FLPMDA; 5.8FLPMDA, 5.8FIPNCACE; 5.8FIPNCBCE; 5.8FIPNCMCE, 7.4GiPEFS; 7.4GSiPEFS;
925053
925053 O-ring
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A
941820
941820 O-ring
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131
925050
925050 O-ring
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ17
955991
955991 O-ring
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ17
925261
925261 O-ring
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B
960214
960214 O-ring
430; 430A; 430B, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, DP-G; TSK DP-G, DPH-A; TSK DPH-B; TSK DPH-A, DPH-D; DPR-D; DPH-D1, DPX-A; TSK DPX-A, DPX-R; DPX-R 1.47; DPX-R 1.51, DP
976044
976044 O-ring
AD31L-A; AD31P-A; AD41L-A, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B