3825339 Volvo.Penta Oscillation damper


3825339 Oscillation damper Volvo.Penta TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P Oscillation
3825339 Oscillation damper Volvo Penta
Rating:
28

Buy Oscillation damper 3825339 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

Information:


Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Note: Before any service work is performed on the air conditioning system, refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Machine Preparation for Troubleshooting".Note: Install caps and plugs to all openings in order to avoid system contamination.
Recover the refrigerant from the air conditioning system. Refer to Testing and Adjusting, SENR5664, "Refrigerant Recovery".
Illustration 1 g00872071
Loosen clamps (1) and disconnect tube (2) from aftercooler (3). Position the tube away from the refrigerant condenser (5).
Remove clips that secure the wiring harness to the refrigerant condenser.
Cut the cable straps (6) that secure the harness assembly to the clips.
Disconnect two hose assemblies (4) from condenser assembly (5). Note: Do not allow the washers that are located behind the condenser to fall to the ground.
Use two people to remove lower mounting bolts (7), the hard washers, the mounts and the nuts from condenser assembly (5).
Repeat Step 6 for the upper mounting bolts.
Remove condenser assembly (5) from the radiator. Installation Procedure
Check all of the O-ring seals and the components for wear or damage. Replace the components, if necessary.
Lubricate all of the O-ring seals lightly with the lubricant that is being sealed.
Add 90 mL (3 fluid oz.) of clean oil to the air conditioning system if a new condenser assembly or remanufactured condenser assembly is installed.
Illustration 2 g00872071
Install condenser assembly (5) to the radiator. Install four bolts (7), the hard washers, the mounts, and the nuts to condenser assembly (5).
Connect two hose assemblies (4) to condenser assembly (5).
Install the clips to the top of the condenser and secure the wiring harness to the clips.
Attach aftercooler tube (2) to aftercooler (3). Tighten hose clamps (1).
Evacuate the air conditioning system. Refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Refrigerant System - Evacuate".
Charge the air conditioning system. Refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Refrigerant System - Charge". End By:
Install the cowling (radiator). Refer to Disassembly and Assembly, "Cowling (Radiator) - Remove and Install".


Back to top