996696 Pin Volvo.Penta
D8A1-A MP; D8A2-A MP
Pin
Price: query
Rating:
Compatible models:
D8A1-A MP; D8A2-A MP
Volvo.Penta
Volvo Penta entire parts catalog list:
Information:
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products.Dispose of all fluids according to local regulations and mandates.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Accidental machine starting can cause injury or death to personnel working on the machine.To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps.Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Cap all lines, all hoses, and all tubes and plug all lines, all hoses, and all tubes. This will help to prevent fluid loss and this will help to keep contaminants from entering the system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Turn the disconnect switch to the OFF position.
Remove the belt. Refer to Operation and Maintenance Manual, "Belts - Inspect/Adjust/Replace".
Illustration 1 g06018289
Disconnect harness assembly (1).
Disconnect hose assembly (2).
Remove bolts (5).
Disconnect hose assembly (6).
Remove bolts (3).
Remove bolts (4).
Remove refrigerant compressor (7).Installation Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Accidental machine starting can cause injury or death to personnel working on the machine.To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps.Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component c
Parts pin Volvo Penta:
950588
950588 Pin
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D120A; D120AK; TD120A, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D70B; D70B PP; D70B K, D
874250
874250 Pin
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-
950548
950548 Pin
D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-D MH, D3-110I-H; D3-140A-H; D3-140I-H, D4-180I-F; D4-225A-F; D4-225I-F, D6-300A-F; D6-300D-F; D6-300I-F, D8A1-A MP; D8A2-A
950550
950550 Pin
D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D8A1-A MP; D8A2-A MP, TAD1640GE; TAD1641GE; TAD1642GE, TAD1641VE; TAD1642VE; TAD1643VE, TAD1643VE-B, TAD1650VE-B; TAD1650VE-B/51VE; TAD1651VE, TAD1670VE; TAD1671VE; TAD1672VE, TAD540-42VE; TAD550
20512324
20512324 Pin
D8A1-A MP; D8A2-A MP, TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
994304
950545
950545 Pin
D8A1-A MP; D8A2-A MP, TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD61