3161224 Volvo.Penta Pipe


3161224 Pipe Volvo.Penta D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE Pipe
3161224 Pipe Volvo Penta
Rating:
78

Buy Pipe 3161224 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 38
 

Volvo Penta entire parts catalog list:

D9A2A; D9A2A D9-425; D9A2A D9-500; D9A2A D9-500 (R4); D9A2A D9-575; D9A2B D9-425; D9A2B D9-500 (R5); D9A2B D9-575; D9A2C D9-425; D9A2D D9
D9A2A; D9A2A MG; D9A2A D9A-MG
TAD940GE; TAD941GE
TAD940VE; TAD941VE; TAD942VE; TAD943VE; TAD950VE; TAD951VE; TAD952VE

Information:


Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Note: Before any service work is performed on the air conditioning system, refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Machine Preparation for Troubleshooting".Note: Install caps and plugs to all openings in order to avoid system contamination.
Recover the refrigerant from the air conditioning system. Refer to Testing and Adjusting, SENR5664, "Refrigerant Recovery".
Illustration 1 g03386082
Illustration 2 g03379361
Loosen hose clamps (1) and (3).
Remove the tube assembly (4) from the aftercooler (2).
Illustration 3 g03386085
Disconnect two hose assemblies (5) from refrigerant condenser assembly (6). Note: Do not allow the washers that are located behind the condenser to fall to the ground.
Use two people to remove lower mounting bolts (7), the hard washers, the mounts and the nuts from refrigerant condenser assembly (5).
Repeat Step 5 for the upper mounting bolts (7).
Remove refrigerant condenser assembly (5). Installation Procedure
Check all of the O-ring seals and the components for wear or damage. Replace the components, if necessary.
Lubricate all of the O-ring seals lightly with the lubricant that is being sealed.
Add 90 mL (3 fluid oz.) of clean oil to the air conditioning system if a new condenser assembly or remanufactured condenser assembly is installed.
Illustration 4 g03386085
Install refrigerant condenser assembly (6). Install four mounting bolts (7), the hard washers, the mounts, and the nuts to refrigerant condenser assembly (6).
Connect two hose assemblies (5) to refrigerant condenser assembly (6).
Illustration 5 g03386082
Illustration 6 g03379361
Attach tube assembly (4) to aftercooler (2). Tighten hose clamps (1) and (3).
Evacuate the air conditioning system. Refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Refrigerant System - Evacuate".
Charge the air conditioning system. Refer to Air Conditioning and Heating, Testing and Adjusting, SENR5664, "Refrigerant System - Charge". End By:
Install the cowling (radiator). Refer to Disassembly and Assembly, "Cowling (Radiator) - Remove and Install".


Parts pipe Volvo Penta:

21442388
 
21442388 Pipe
D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D9A2A; D9A2A D9-425; D9A2A D9-500
20951337
 
20951337 Pipe
D11A-A; D11A-B; D11A-C, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG
469543
Pipe flange
469543 Pipe flange
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A
3842968
 
3842968 Pipe
D9A2A; D9A2A D9-425; D9A2A D9-500
21186630
 
21186630 Pipe
D9A2A; D9A2A D9-425; D9A2A D9-500
20734497
 
20734497 Pipe
D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE
20397944
 
20397944 Pipe
TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE
11127377
 
11127377 Pipe
TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE
Back to top