331868 Volvo.Penta Piston


331868 Piston Volvo.Penta D100A; D100AK; D100B Piston
331868 Piston Volvo Penta
Rating:
53

Buy Piston 331868 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$59.00
 

16-02-2024
1.0[0.45] pounds
US: forestcity1
Worthington Rosin Core Solder, Dia 0.062 in, 1lb
Worthington Made in United States
Number on catalog scheme: 32
 

Compatible models:

D100A; D100AK; D100B   Volvo.Penta

Volvo Penta entire parts catalog list:

D100A; D100AK; D100B; TD100A; TD100AG; TD100AK

Information:


Table 1
Diagnostic Trouble Codes
J1939 Code CDL Code Code Description
(code descriptions may vary Comments
105-3 172-3 Engine Intake Manifold #1 Temperature : Voltage Above Normal The Electronic Control Module (ECM) detects the following conditions:
The signal voltage from the intake manifold air temperature sensor is greater than 4.95 VDC for more than 8 seconds.
Engine coolant temperature is above −10 °C (15.0 °F).
The ECM will use the default value of 70 °C (158 °F) for the intake manifold air temperature. "Voltage High" will be displayed next to the status for "Intake Manifold Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
105-4 172-4 Engine Intake Manifold #1 Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the intake manifold air temperature sensor is less than 0.2 VDC for more than 8 seconds.
The ECM will use the default value of 70 °C (158°F) for the intake manifold air temperature. "Voltage Low" will be displayed next to the status for "Intake Manifold Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
110-3 110-3 Engine Coolant Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the engine coolant temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Above Normal" will be displayed next to the status for "Engine Coolant Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
White smoke
110-4 110-4 Engine Coolant Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the engine coolant temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Below Normal" will be displayed next to the status for "Engine Coolant Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
White smoke
441-3 1836-3 Auxiliary Temperature #1 : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the auxiliary temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Above Normal" will be displayed next to the status for "Auxiliary Temperature" on the electronic service tool.
441-4 1836-4 Auxiliary Temperature #1 : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the auxiliary temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Below Normal" will be displayed next to the status for "Auxiliary Temperature" on the electronic service tool.
2630-3 3372-3 Engine Charge Air Cooler Outlet Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the ATAAC outlet temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Above Normal" will be displayed next to the status for "ATAAC Temperature" on the electronic service tool.
2630-4 3372-4 Engine Charge Air Cooler Outlet Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the ATAAC outlet temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Below Normal" will be displayed next to the status for "ATAAC Temperature" on the electronic service tool.
- 171-4 Ambient Air Temperature Sensor voltage below normal The ECM detects the following conditions:
The signal voltage from the ambient air temperature sensor is less than 0.2 VDC for more than 8 seconds.
"Voltage Low" will be displayed next to the status for "Ambient Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
- 600-3 Hydraulic Oil Temperature Sensor voltage above normal The ECM detects the following conditions:
The signal voltage from the hydraulic oil temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Above Normal" will be displayed next to the status for "Hydraulic Oil Temperature" on the electronic service tool.
- 600-4 Hydraulic Oil Temperature Sensor voltage below normal The ECM detects the following conditions:
The signal voltage from the hydraulic oil temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Below Normal" will be displayed next to the status for "Hydraulic Oil Temperature" on the electronic service tool.
Follow the troubleshooting procedure in order to identify the root cause of the fault. Note: The following conditions must exist before any of the above codes will become active:
The ECM has been powered for at least 2 seconds.
There are no active 168-X diagnostic codes.The ECM will log the diagnostic code. If equipped, the warning light will come on.The following background information is related to this procedure:The troubleshooting procedures for the diagnostic codes of each temperature sensor are identical. The temperature sensors have two terminals. The signal line is connected to each sensor connector terminal 1. Terminal 2 is the return


Parts piston Volvo Penta:

323482
Piston
323482 Piston
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D70B; D70B PP; D70B K, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
331876
Piston
331876 Piston
D100A; D100AK; D100B, D120A; D120AK; TD120A, D70B; D70B PP; D70B K, TD100G; TD100G-85; TD100G-87, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD61A; TD61AW; TD61ACE, TD70G; TD70G-83; TD70GPP
324332
Piston
324332 Piston
D100A; D100AK; D100B
324333
 
324333 Piston
D100A; D100AK; D100B
1518359
 
1518359 Piston
D100A; D100AK; D100B, TD120C, TD61A; TD61AW; TD61ACE, TD70G; TD70G-83; TD70GPP, TID120FPP; TID120FG; TD120G
1518360
 
1518360 Piston
D100A; D100AK; D100B, TD120C, TD61A; TD61AW; TD61ACE, TD70G; TD70G-83; TD70GPP, TID120FPP; TID120FG; TD120G
1518361
 
1518361 Piston ring
D100A; D100AK; D100B, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87, TD120C, TD120HP-86; TD121; TD121G, TD61A; TD61AW; TD61ACE, TD70G; TD70G-83; TD70GPP, TID120FPP; TID120FG; TD120G, TWD1230ME, TWD610P; TWD610PB; TWD710P
945520
 
945520 Piston seal
D100A; D100AK; D100B, D120A; D120AK; TD120A, D70B; D70B PP; D70B K
Back to top