876542 Piston ring kit Volvo.Penta
TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TD610G; TWD610G; TD710G, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P
Piston
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$112.00
13-12-2023
0.0022[0.00] pounds
CN: JUXINJIAYE
Ventilation Chimney Cowl,Anti-Downdraught Top All Purpose Chimney Cowl,Stainless Steel Anti Downdraught Chimney Cowl, For Factory, Farm, Production Workshop, Kitchen (Size : 300mm/11.81in)
JUCCJUXIN **Wide range of application: widely used in large-scale factories, warehouses, stadiums, livestock farms, high-rise buildings, residential buildings, etc., to effectively remove indoor oily smoke, smoke, peculiar smell, moisture, heat, and decoration Harmful gas and dust etc,Can be installed directly without complicated assembly; || **Unpowered roof vent: The turbine fan uses the convection theory of natural wind and air to accelerate and transform parallel airflow into vertical airflow, thereby improving indoor ventilation. The hot air rises ,Hat designed to rotate with the action of the wind, so that the more the wind blows, the more the blades rotate, and the more powerful the air intake is from the inside out. || **Principle Of Operation:the rings of this chimney cowl are specially designed and placed over the other in a way that the wind cannot go down the chinmey, thus making this cap a prefect anti downdraught solution.enough to prevent rainwater from entering the ventilation system. || **Protect your chimney from rain and moisture, which is especially suitable for chimneys that are not used frequently.Stainless steel construction Thickened fixed feet; Spinner Anti-Downdraught Fits Most Standard Chimney Pots Very effective in preventing wind and increasing ventilation. || **Stainless Steel Rotating Chimney Cowl Cap: Spinner Anti-Downdraught Fits Most Standard Chimney Pots Very effective in preventing wind and increasing ventilation.Rotating hood for ventilation pipes, smoke chimneys, and air extraction.The gairing provides maximum protection without hindering the performance of the chimney.
JUCCJUXIN **Wide range of application: widely used in large-scale factories, warehouses, stadiums, livestock farms, high-rise buildings, residential buildings, etc., to effectively remove indoor oily smoke, smoke, peculiar smell, moisture, heat, and decoration Harmful gas and dust etc,Can be installed directly without complicated assembly; || **Unpowered roof vent: The turbine fan uses the convection theory of natural wind and air to accelerate and transform parallel airflow into vertical airflow, thereby improving indoor ventilation. The hot air rises ,Hat designed to rotate with the action of the wind, so that the more the wind blows, the more the blades rotate, and the more powerful the air intake is from the inside out. || **Principle Of Operation:the rings of this chimney cowl are specially designed and placed over the other in a way that the wind cannot go down the chinmey, thus making this cap a prefect anti downdraught solution.enough to prevent rainwater from entering the ventilation system. || **Protect your chimney from rain and moisture, which is especially suitable for chimneys that are not used frequently.Stainless steel construction Thickened fixed feet; Spinner Anti-Downdraught Fits Most Standard Chimney Pots Very effective in preventing wind and increasing ventilation. || **Stainless Steel Rotating Chimney Cowl Cap: Spinner Anti-Downdraught Fits Most Standard Chimney Pots Very effective in preventing wind and increasing ventilation.Rotating hood for ventilation pipes, smoke chimneys, and air extraction.The gairing provides maximum protection without hindering the performance of the chimney.
Compatible models:
Volvo Penta entire parts catalog list:
- Crank Mechanism: B » 876542
- Repair Kits
TAMD72P-A; TAMD72WJ-A
TD610G; TWD610G; TD710G; TWD710G; TAD730G; TWD740GE; TAD740GE; TAD741GE
TD71A; TID71A; TWD710V; TD730VE; TWD731VE; TAD730V; TWD740VE
TWD610P; TWD610PB; TWD710P; TWD710PB; TAD730P
Information:
Table 1
Tools Needed
Part Number Part Name Quantity
1U-5470
or
198-4240 Engine Pressure Group
or
Digital Pressure Indicator Gp 1
Illustration 1 g00293196
1U-5470 Engine Pressure Group
Refer to Special Instruction, SEHS8907, "Using the 1U-5470 Engine Pressure Group" for the instructions that are needed to use the 1U-5470 Engine Pressure Group. Refer to Operation Manual, NEHS0818, "Using the 198-4240 Digital Pressure Indicator Gp" for the instructions that are needed to use the 198-4240 Digital Pressure Indicator Gp.
Inspect the engine air cleaner inlet and ducting in order to ensure that the passageway is not blocked or collapsed.
Inspect the engine air cleaner element. Replace a dirty engine air cleaner element with a clean engine air cleaner element.
Check for dirt tracks on the clean side of the engine air cleaner element. If dirt tracks are observed, contaminants are flowing past the engine air cleaner element and/or the seal for the engine air cleaner element.
Hot engine components can cause injury from burns. Before performing maintenance on the engine, allow the engine and the components to cool.
Making contact with a running engine can cause burns from hot parts and can cause injury from rotating parts.When working on an engine that is running, avoid contact with hot parts and rotating parts.
Use the differential pressure gauge from the 1U-5470 Engine Pressure Group or the 198-4240 Digital Pressure Indicator Gp.
Connect the vacuum port of the differential pressure gauge to the test location . The test location can be located anywhere along the air inlet piping after the engine air cleaner but before the turbocharger.
Leave the pressure port of the differential pressure gauge open to the atmosphere.
Start the engine. Run the engine in the no-load condition at high idle.
Record the value.
Multiply the value from Step 4d by 1.8.
Compare the result from Step 4e to the appropriate values that follow. The air flow through a used engine air cleaner may have a restriction. The air flow through a plugged engine air cleaner will be restricted to some magnitude. In either case, the restriction must not be more than the following amount: Maximum restriction ... 6.2 kPa (25 in of H2O)The air flow through a new engine air cleaner element must not have a restriction of more than the following amount: Maximum restriction ... 3.7 kPa (15 in of H2O)Exhaust Restriction
Back pressure is the difference in the pressure between the exhaust at the outlet elbow and the atmospheric air.
Hot engine components can cause injury from burns. Before performing maintenance on the engine, allow the engine and the components to cool.
Making contact with a running engine can cause burns from hot parts and can cause injury from rotating parts.When working on an engine that is running, avoid contact with hot parts and rotating parts.
Use the differential pressure gauge of the 1U-5470 Engine Pressure Group in order to measure back pressure from the exhaust. Use the following procedure in order to measure back pressure from the exhaust:
Connect the pressure port of the differential pressure gauge to test location. The test location is located on the exhaust piping after the turbocharger.
Leave the vacuum port of the differential pressure gauge open to the atmosphere.
Start the engine. Run the engine in the no-load condition at high idle.
Record the value.
Multiply the value from Step 4 by 1.8.
Compare the result from Step 5 to the value that follows. Back pressure from the exhaust must not be more than the following amount: Maximum back pressure ... 10.0 kPa (40 in of H2O)
Parts piston Volvo Penta:
471646
471646 Piston cooling valve
D12D-A MH; D12D-B MH; D12D-C MH, TAD1240GE; TAD1241GE; TAD1242GE, TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A,
244831
244831 Piston
DH10A; DH10A 285; DH10A 360, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD122A; TMD122A; TAMD122P-A, TAMD16
862461
862461 Piston
DH10A; DH10A 285; DH10A 360, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD122A; TMD122A; TAMD122P-A, TAMD16
420628
420628 Piston cooling jet
TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD610G; TWD610G; TD710G, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P
1697282
1697282 Piston
TAD1230P; TD121GP-87; TWD1210P, TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD121G-87; TWD1210V; TWD1211V, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD1230ME, TWD610P; TWD
270614
270614 Piston ring kit
TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87, TD120HP-86; TD121; TD121G, TD61A; TD61AW; TD61ACE, TWD1230ME, TWD610P; TWD610PB; TWD710P
3094156
477437
477437 Piston cooling jet
TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD71A; TID71A; TWD710V