20405716 Volvo.Penta Plug


20405716 Plug Volvo.Penta D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TAD550GE; TAD551GE; TAD750GE, TAD560VE; TAD561VE; TAD761VE, TAD650VE; TAD660VE, TAD734GE, TAD750VE; TAD760VE, TD420VE; TAD420VE; TAD620VE, T Plug
20405716 Plug Volvo Penta
Rating:
13

Buy Plug 20405716 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 7
 

Volvo Penta entire parts catalog list:

D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA
D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA; D7C-TA; D7C-B TA
TAD520GE; TAD720GE; TAD721GE; TAD722GE
TAD520VE; TAD720VE; TAD721VE; TAD722VE
TAD550GE; TAD551GE; TAD750GE; TAD751GE; TAD752GE; TAD753GE; TAD754GE
TAD560VE; TAD561VE; TAD761VE; TAD762VE; TAD763VE; TAD764VE; TAD765VE
TAD650VE; TAD660VE
TAD734GE
TAD750VE; TAD760VE
TD420VE; TAD420VE; TAD620VE
TD520GE; TAD530GE; TAD531GE; TAD532GE; TD720GE; TAD720GE; TAD730GE; TAD731GE; TAD732GE; TAD733GE; TAD530GE MECH; TAD530GE EDC4; TAD531GE MEC
TD520VE; TD720VE

Information:


Table 2
Connector B (17Contacts)    
Contact Number     Description    
14     Auxiliary input 6. This is a negative switched configurable input. Refer to "P810 For Windows" configuration manual for options available. It is possible to configure the input to be a normally closed signal or a normally open signal.    
15     Auxiliary input 7. This is a negative switched configurable input. Refer to "P810 For Windows" configuration manual for options available. It is possible to configure the input to be a normally closed signal or a normally open signal.    
16     Auxiliary input 8. This is a negative switched configurable input. Refer to "P810 For Windows" configuration manual for options available. It is possible to configure the input to be a normally closed signal or a normally open signal.    
17     Auxiliary input 9. This is a negative switched configurable input. Refer to "P810 For Windows" configuration manual for options available. It is possible to configure the input to be a normally closed signal or a normally open signal.    
18     Auxiliary relay output 3. Plant supply positive. Configurable output. Refer to "P810 For Windows" configuration manual for options available.    
19     Auxiliary relay output 4. Plant supply positive. Congigurable output. Refer to "P810 For Windows" configuration manual for options available.    
20     Magnetic input positive. An AC signal from the engine speed sensor positive for speed sensing.    
21     Magnetic input negative. An AC signal from the engine speed sensor negative for speed sensing.    
22     Oil pressure sensing input. Connect to resistive type oil pressure sender. Refer to Testing and Adjusting, "Typical Wiring Diagrams" for details.    
23     Coolant temperature sensing input. Connect to resistive type coolant temperature sender. Refer to Testing and Adjusting, "Typical Wiring Diagrams" for details.    
24     Sender common connection. Return feed from sender units. Refer to Testing and Adjusting, "Typical Wiring Diagrams" for details.    
25     Generator "L1" current transformer connection.    
26     Generator "L2" current transformer connection. If single phase is used, do not connect this Contact.    
27     Generator "L3" current transformer connection. If single phase is used do not connect this Contact.    
28 (1)     Generator current transformer common connection.    
29 (1)     Generator current transformer neutral connection and CT ground connection.    
30     Functional ground. Ensure connection to a good clean ground contact.    
( 1 ) Refer to Testing and Adjusting, "Typical Wiring Diagrams" for 3 CT and 4 CT wiring difference.
( 1 )
Table 3
Connector C (4 Contacts)    
Contact Number    Description    
31     Generator "L1" sensing input. Connect to alternator "L1" output.    
32     Generator "L2" sensing input. Connect to alternator "L2" output. If using single phase only do not connect this terminal.    
33     Generator "L3" sensing input. Connect to alternator "L3" output. If using single phase only, do not connect this terminal.    
34     Generator "N" sensing input. Connect to alternator "N" output.    
Table 4
Connector D (11 Contacts) (1)    
Contact Number    Description    
35     Generator loading relay (AUX relay 5), normally open, volts-free contacts to Contact "36". Used to connect to generator contactor or circuit breaker.    
36     Generator loading relay (AUX relay 5), normally open, volts free contacts to Contact "35". Used to connect to generator contactor or circuit breaker.    
37     Do Not Use    
38     Generator close request relay (AUX relay 6), normally closed changeover, volts-free contacts to Contact "39".    
39     Generator close request relay (AUX relay 6), changeover, volts-free contacts to Contact "38" and Contact


Parts plug Volvo Penta:

838928
Plug
838928 Plug
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQD70D; TAMD70D; TAMD70E, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D4-180I-B; D4-180I-C; D4-18
952075
Plug
952075 Plug
1372, 430; 430A; 430B, 5.0GL-F; 5.0GL-FF, 5.0GL-H; 5.0GL-HF, 5.0GL-J; 5.0GL-JF, 5.0GXi-270-R, 5.0GXi-A; 5.7Gi-A; 5.7GXi-A, 5.0GXi-B; 5.0GXi-BF; 5.0OSi-B, 5.0GXi-C; 5.0GXi-CF; 5.0GXi-D, 5.0GXi-E; 5.0GXi-EF; 5.0OSi-E, 5.0GXi-F; 5.0GXi-FF; 5.0OSi-F, 5.0
945065
Plug
945065 Plug
1372, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D5A-T; D5A-TA; D5A-B TA, D5A-T; D
974680
 
974680 Plug
D13B-J MP; D13B-M MP, D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, D9A2A; D9A2A D9-425; D9A2A D9-500, TAMD103A
20459195
 
20459195 Plug
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TAD550GE; TAD551GE; TAD750GE, TAD560VE; TAD561VE; TAD761VE, TAD650VE; TAD660VE, TAD734GE, TAD750VE; TAD760VE, TD420VE; TAD420VE; TAD620VE, T
20412269
 
20412269 Plug
TAD520GE; TAD720GE; TAD721GE, TD520GE; TAD530GE; TAD531GE, TD520VE; TD720VE
21011809
 
21011809 Plug
TAD550GE; TAD551GE; TAD750GE
20459191
 
20459191 Plug
TAD650VE; TAD660VE, TD420VE; TAD420VE; TAD620VE
Back to top