21796164 Volvo.Penta Plug


21796164 Plug Volvo.Penta TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE Plug
21796164 Plug Volvo Penta
Rating:
33

Buy Plug 21796164 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 4
 

Volvo Penta entire parts catalog list:

TAD540-42VE; TAD550-51VE; TAD540VE; TAD541VE; TAD542VE; TAD550VE; TAD551VE; TAD552VE
TAD570VE; TAD571VE; TAD572VE
TAD840VE; TAD841VE; TAD842VE; TAD843VE; TAD852VE; TAD851VE; TAD853VE; TAD850-52VE; TAD840-43VE
TAD870VE; TAD871VE; TAD872VE; TAD873VE

Information:

A Rating (Continuous)
* For heavy-duty service when engine is operated at rated load and speed up to 100 percent of the time without interruption or load cycling.* Time at full load up to 100 percent of the duty cycle.* Typical examples are: pipeline pumping, ventilation, and customer specifications.B Rating
* For service where power and/or speed are cyclic.* Time at full load not to exceed 80 percent of the duty cycle.* Typical examples are: irrigation where normal pump demand is 85 percent of the duty cycle, oil field mechanical pumping and drilling, and stationary/plant air compressors.C Rating (Intermittent)
* For service where power and/or speed are cyclic.* The horsepower and speed capability of the engine can be used for one uninterrupted hour, followed by one hour of operation at or below the A rating.* Time at full load not to exceed 50 percent of the duty cycle.* Typical examples are: agricultural tractors, harvesters and combines, off-highway trucks, fire pump application power, blast hole drills, rock crushers and wood chippers with high torque rise, and oil field hoisting.D Rating
* For service when rated power is required for periodic overloads.* The maximum horsepower and speed capability of the engine can be used for a maximum of 30 uninterrupted minutes, followed by one hour of followed by one hour of C rating operation.* Time at full load not to exceed 10 percent of the duty cycle.* Typical examples are: offshore cranes, runway snow blowers, water well drills, portable air compressors, and fire pump certification power.E Rating
* For service where rated power is required for a short time for initial starting or sudden overload. For emergency service where standard power is unavailable.* The maximum horsepower and speed capability of the engine can be utilized for a maximum of 15 uninterrupted minutes, followed by one hour at C rating operation, or for the duration of the emergency.* Time at full load is not to exceed 5 percent of the duty cycle.* Typical examples are: standby centrifugal water pumps, oil field well servicing, crash trucks, and gas turbine starters.Rating Conditions
Unless otherwise specified, all ratings are based on SAE J1349 standard ambient conditions:* 100 kPa (29.6 inches of Hg) of pressure* 30 percent relative humidity, and* a temperature of 26°C (77°F).Ratings also apply at AS1501, BS5514, DIN6271, and ISO3046/1 standard conditions.Power for diesel engines is based on:* API gravity of 35 at 15°C (60°F),* fuel LHV of 42.780 kJ/g (18390 Btu/lb) at 29°C (84°F), and* fuel density of 839 g/L (7 lb/US gal)Ratings are gross output ratings- the total output capability of the engine equipped with standard accessories. Standard accessories include pumps for lubrication oil, fuel, and jacket water, and magneto as required. The gross output, minus the power required to drive auxiliary components, equals the net power available for the external (flywheel) load. Typical auxiliary components include cooling fans, air compressors, and charging alternators.Ratings must be reduced to compensate for altitude conditions, according to the applicable engine test specification derating data at normal ambient temperature.Generator Set Engine Ratings
All ratings shown are subject to manufacturing tolerances of plus or minus three percent.Standby Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 100.* Typical peak demand: 80 percent of the Standby rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical Application: Building Service Standby with enclosed sheltered environment.Prime Plus 10 Percent Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 500.* Typical peak demand: 80 percent of the Prime Plus 10 Percent rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical applications: Standby, Rental Unit, Power Module, Unreliable Utility, and Interruptible Rates.Prime Rating
* Typical load factor: 60 to 70 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated output is used for less than 10 percent of the operating hours.* Typical applications: Industrial, Pumping, Construction, Peak Shaving, and Cogeneration.Continuous Rating
* Typical load factor: 70 to 100 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated kW is used for less than 100 percent of the operating hours.* Typical application: Base Load, Utility, and Cogeneration.
Operating units above the rating definitions will result in shorter service life before overhaul.


Parts plug Volvo Penta:

479979
Plug
479979 Plug
1372, 2001; 2001B; 2001AG, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D4-180I-B; D4-18
968062
Plug
968062 Plug
D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D5A-T; D5A-TA; D5A-B TA, D6-300A-F; D6-300D-F; D6-300I-F, D9A2A; D9A
943920
 
943920 Plug
1372, 2001; 2001B; 2001AG, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 8.1GiCE-J; 8.1GiCE-JF; 8.1GiCE-M, 8.1GiE-JF; 8.1GiE
941269
 
941269 Plug
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
990828
Plug
990828 Plug
D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE;
968063
 
968063 Plug
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-2
966142
 
966142 Plug
D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13B-J MP; D13B-M MP, D13C1-A MP; D13C2-A MP; D13C3-A MP, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280
914390
 
914390 Plug
AQ115A; AQ115B; AQ130, D13C1-A MP; D13C2-A MP; D13C3-A MP, D70CHC; D70CRC; TD70CHC, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAD570VE; TAD571VE; TAD572VE, TAD870VE; TAD871VE; TAD872VE, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD1
Back to top