940375 Plug Volvo.Penta
230A; 230B; 250A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, TD610G; TWD610G; TD710G, TD71A; TID71A; TWD710V
Plug
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Hacus - Forklift FPE479710 ALTERNATOR 12V 65A Hacus Aftermarket - New
Hacus HIGH-QUALITY CONSTRUCTION: Made with premium materials; built to withstand the demands of industrial environments; offering excellent resistance to wear; corrosion; and mechanical stress. || VERSATILE COMPATIBILITY: Engineered to fit a wide range of forklift models; making it a versatile choice for various equipment configurations. || SAFETY FIRST - FPE products are ready for use with all certifications. || LEADING THE INDUSTRY - FPE is a leader in forklift products and accessories. We take pride in making the highest quality, premium, reliable forklifts on the market. || All products tested for durability, reliability, and performance.
Hacus HIGH-QUALITY CONSTRUCTION: Made with premium materials; built to withstand the demands of industrial environments; offering excellent resistance to wear; corrosion; and mechanical stress. || VERSATILE COMPATIBILITY: Engineered to fit a wide range of forklift models; making it a versatile choice for various equipment configurations. || SAFETY FIRST - FPE products are ready for use with all certifications. || LEADING THE INDUSTRY - FPE is a leader in forklift products and accessories. We take pride in making the highest quality, premium, reliable forklifts on the market. || All products tested for durability, reliability, and performance.
Global Industrial Steel Double Socket Base for Pedestrian Barrier
Global Industrial 8 lbs, Steel construction || Double socket base
Global Industrial 8 lbs, Steel construction || Double socket base
Nissens Air Conditioning Condenser/Receiver Drier Assembly - 940375
Nissens Nissens condensers provide the complete solution - extended durability, OE matching quality, perfect fit and finish, and ease of installation. Nissens condensers are manufactured with a highly resistant anti-corrosion coating technology that protects against exposure to harsh conditions, such as moisture, road salt, and extreme temperature changes. Designed and tested to considerably extend the part life-span.
Nissens Nissens condensers provide the complete solution - extended durability, OE matching quality, perfect fit and finish, and ease of installation. Nissens condensers are manufactured with a highly resistant anti-corrosion coating technology that protects against exposure to harsh conditions, such as moisture, road salt, and extreme temperature changes. Designed and tested to considerably extend the part life-span.
Compatible models:
Volvo Penta entire parts catalog list:
AQ125B
AQ131A; AQ131B; AQ131C; AQ131D
AQ145B
AQ151A; AQ151B; AQ151C
TD610G; TWD610G; TD710G; TWD710G; TAD730G; TWD740GE; TAD740GE; TAD741GE
TD71A; TID71A; TWD710V; TD730VE; TWD731VE; TAD730V; TWD740VE
Information:
Table 1
Diagnostic Trouble Codes    
CDL Code    Code Description    Comments    
3397-3     DPF #1 Soot Loading Sensor : Voltage Above Normal     The Electronic Control Module (ECM) detects voltage that is not in the acceptable range.
The code is logged.    
3397-4     DPF #1 Soot Loading Sensor : Voltage Below Normal     The ECM detects voltage that is not in the acceptable range.
The code is logged.    
3397-19     DPF #1 Soot Loading Sensor : Data Drifted Low     There is an electrical problem with soot sensing system.
The code is logged.    
3397-21     DPF #1 Soot Loading Sensor : Data Error     There is an electrical problem with soot sensing system.
The code is logged.    Test Step 1. Check for Active Diagnostic Codes
Establish communication between the Cat ET and the engine ECM.
Turn the keyswitch to the ON position.
Download the engine "Warranty Report" before performing any troubleshooting or clearing diagnostic trouble codes.
Troubleshoot any associated codes that are listed in Table 2 before continuing with this procedure.
Table 2
Associated Diagnostic Trouble Codes    
168     2,3 or 4    Results:
An associated code is active. - Repair: Troubleshoot the associated code.Verify that the problem is resolved.STOP
The 3397-3 diagnostic code is active. The voltage to the soot sensing system is above 32 VDC. - Repair: There is a problem with the harness and/or the connectors for the soot sensing module. Repair the harness and/or connectors or replace the harness and/or connectors. Refer to Illustration 1 for additional information.Verify that the problem is resolved.STOP
The 3397-4 diagnostic code is active. The voltage to the soot sensing system is below 9 VDC. - Repair: There is a problem with the harness and/or the connectors for the soot sensing module. Repair the harness and/or connectors or replace the harness and/or connectors. Refer to Illustration 1 for additional information.Verify that the problem is resolved.STOP
The 3397-21 diagnostic code is active. There is an electrical and/or mechanical problem with the soot sensing system. - Proceed to Test Step 2.Test Step 2. Check the Coaxial Cable and the Soot Sensing Module
Illustration 1 g02161091
Soot sensing module and connector
Inspect the coaxial cable. Verify that every connection for the coaxial cable in the soot sensing system is securely connected. Also, check each connection for dirt and water. The dirt and water must be cleaned from the connector each time a connection is made.
Illustration 2 g02177161
Connector torque point (1) Torque point
Torque every connector for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).
Reset all active codes and clear all logged codes. Verify that the problem is resolved.
If the problem is not resolved, disconnect the coaxial cable from the antennas.
Illustration 3 g02151941
366-7782 Attenuator
Connect the ends of the coaxial cable to the 366-7782 Attenuator . Refer to Illustration 3.
Perform the "DPF Soot Loading Sensor Functional Test" on Cat ET by selecting the following menus:
"Diagnostics"
"Diagnostic Tests"
"DPF Soot Loading Sensor Functional Test"Results:
The service test is successful. - Repair: Remove the antennas from the DPF in order to inspect for bent or broken probes.Replace any faulty antennas and reinstall the good antenna (if applicable).Torque the connector's for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).Verify that the problem is resolved.STOP
The service test is not successful. - Repair: Replace the soot sensing module.Torque the connectors for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).Verify that the problem is resolved.STOP
Parts plug Volvo Penta:
191830
191830 Plug
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ175A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQ290A, D2-55; D2-
948187
948187 Plug
230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ1
845071
845071 Plug
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A
467367
467367 Plug
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13
968145
968145 Plug
230A; 230B; 250A, 251A, 4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 430; 430A; 430B, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5.8FiPMDA, 5.0FI
968061
968061 Plug
D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, D9A2A; D9A2A D9
968144
968144 Plug
230A; 230B; 250A, 251A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, D12D-A MH; D12D-B MH; D12D-C MH
681429
681429 Plug
TAMD60A; TAMD60B, TAMD60C, TAMD63L-A; TAMD63P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD120C, TD120HP-86; TD121; TD121G, TD30A; TD31ACE; TD40A, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD610M; TD630ME; TWD630ME,