31272680 Volvo.Penta Pressure pipe


31272680 Pressure pipe Volvo.Penta D3-110I-A; D3-110I-B; D3-110I-C Pressure
31272680 Pressure pipe Volvo Penta
Rating:
48

Buy Pressure pipe 31272680 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 10
 

Compatible models:

Volvo Penta entire parts catalog list:

D3-110I-A; D3-110I-B; D3-110I-C; D3-130A-A; D3-130I-A; D3-130A-B; D3-130I-B; D3-130A-C; D3-130I-C; D3-160A-A; D3-160I-A; D3-160A-B; D3-160I-

Information:


Illustration 1 g00488507
System Schematic For Run Relay (RR)The contacts for the run relay (RR) are available for use by the customer. The RR is located within the relay module. The GSC activates the run relay (RR) during engine cranking and running.Note: Whenever the GSC activates the RR, "K5" is shown on the lower display. "K5" is also shown on the lower display when the GSC attempts to activate the crank terminate relay. When the RR is not activated, "K5" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the RR.The following response is the system response to this fault while the RR is activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is deactivated. Also, any equipment that is connected to RM-23 is activated.The following response is the system response to this fault while the RR is not activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is not activated. Also, any equipment that is connected to RM-23 remains activated.The GSC treats this diagnostic code as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 445 FMI 12 is showing.
If this diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 445 FMI 12 is showing as a active fault or an inactive fault. Results:
No - A CID 445 FMI 12 has not occurred (NOT active and NOT inactive). STOP.
Yes - A CID 445 FMI 12 is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK - Reassemble the relay module to the GSC. Proceed to 3.
NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.
Perform a functional check for the RR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-24 of the relay module. Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be greater than 5000 ohms.
Turn the ECS to the START position. Make sure that "K5" is showing on the lower display.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be less than 5 ohms.Expected Result: For 3.c, the resistance should be greater than 5000 ohms. For 3.e, the resistance should be less than 5 ohms.Results:
OK - It is likely that a temporary bad electrical connection existed and this troubleshooting procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK - Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts pressure Volvo Penta:

30731826
 
30731826 Pressure pipe
D3-110I-A; D3-110I-B; D3-110I-C
30731828
 
30731828 Pressure pipe
D3-110I-A; D3-110I-B; D3-110I-C
30637150
Pressure sensor
30637150 Pressure sensor
D3-110I-A; D3-110I-B; D3-110I-C
3884352
 
3884352 Pressure sensor
D3-110I-A; D3-110I-B; D3-110I-C, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C
3884353
 
3884353 Pressure limiting va
D3-110I-A; D3-110I-B; D3-110I-C, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
31216005
 
31216005 Pressure pipe
D3-110I-A; D3-110I-B; D3-110I-C
31272621
 
31272621 Pressure pipe
D3-110I-A; D3-110I-B; D3-110I-C
31216007
 
31216007 Pressure pipe
D3-110I-A; D3-110I-B; D3-110I-C
Back to top