849302 Pressure pipe, cyl 6 Volvo.Penta
TAD1630P; TWD1630P; TWD1630PP, TID162AG; TID162AGP; TID162AP
Pressure
Price: query
Rating:
Compatible models:
Volvo Penta entire parts catalog list:
TID162AG; TID162AGP; TID162AP; TID162APB
Information:
Illustration 1 g00285112
Typical solenoid
The solenoid has windings (one or two sets) around a hollow cylinder. There is a spring-loaded plunger inside the cylinder. The plunger can move forward and backward. When the start switch is closed and the electricity is sent through the windings, a magnetic field is made. The magnetic field pulls the plunger forward in the cylinder. The shift lever moves to engage the pinion drive gear with the ring gear. The front end of the plunger makes contact across the battery and the motor terminals of the solenoid. The starting motor begins to turn the flywheel of the engine.When the start switch is opened, current no longer flows through the windings. The spring pushes the plunger back to the original position. The spring simultaneously moves the pinion gear away from the flywheel.When two sets of windings in the solenoid are used, the windings are called the hold-in winding and the pull-in winding. Both of the winding have the same number of turns around the cylinder. However, the pull-in winding uses a wire with a larger diameter to produce a greater magnetic field. When the start switch is closed, part of the current flows from the battery through the hold-in windings. The rest of the current flows through the pull-in windings to the motor terminal. The current then goes through the motor to the ground. When the solenoid is fully activated, current is shut off through the pull-in windings. Only the smaller hold-in windings are in operation for the extended period. This period is equal to the amount of time that is needed for the engine to start. The solenoid will now take less current from the battery. The heat that is made by the solenoid will be kept at an acceptable level.Starting Motor
The starting motor is used to turn the engine flywheel to get the engine running.
Illustration 2 g01192489
Typical cross section of the starting motor
(1) Field
(2) Solenoid
(3) Clutch
(4) Pinion
(5) Commutator
(6) Brush assembly
(7) ArmatureThe starting motor has a solenoid. When the start switch is activated, electricity will flow through the windings of the solenoid. The solenoid core will move to push the starting motor pinion with a mechanical linkage. As the linkage moves, the ring gear engages the flywheel of the engine. The starting motor pinion engages with the ring gear prior to the electrical contacts closing in the solenoid. As the contacts close, the circuit between the battery and the starting motor is engaged. When the circuit between the battery and the starting motor is complete, the pinion will turn the engine flywheel. A clutch gives protection to the starting motor. The engine cannot turn the starting motor too fast. When the start switch is released, the starting motor pinion will move away from the flywheel ring gear.Starting Motor Protection
The starting motor is protected from damage in two ways:
The starting motor is protected from engagement with the flywheel while the engine is running. The control feature will not allow the starting motor to engage if the engine speed is above 0 rpm.
The starting motor is protected from continued operation when holding the key in the "start" position after the engine starts. The Electronic Control Module (ECM) automatically disengages the starting motor solenoid when engine speed reaches 400 rpm.
Parts pressure Volvo Penta:
477173
477173 Pressure equalizer
D70CHC; D70CRC; TD70CHC, DH10A; DH10A 285; DH10A 360, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD103A, TA
863169
863169 Pressure monitor
2001; 2001B; 2001AG, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, DH10A; DH10A 285; DH10A 360, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD4
842037
842037 Pressure drop indica
D100A; D100AK; D100B, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, TAD1030P, TAD1630P; TWD1630P; TWD1630PP, TD100G-87; TD1030ME; TWD1030ME, TD100G; TD100G-85; TD100G-87, TD120C, TD1
846531
846531 Pressure plate
D100A; D100AK; D100B, D120A; D120AK; TD120A, MD120A; MD120AK; TMD120A, TAD1030P, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAD1641VE; TAD1642VE; TAD1643VE, TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE, TAM
866095
866095 Pressure cap
TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD1
1556464
1556464 Pressure pipe, incl fitting and ferrule
TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TD164KAE, TID162AG; TID162AGP; TID162AP, TWD1620G; TWD1630G; TAD1630G
849297
849298