242840 Volvo.Penta Protecting casing


242840 Protecting casing Volvo.Penta MD70B; MD70BK; TMD70B Protecting
242840 Protecting casing Volvo Penta
Rating:
43

Buy Protecting casing 242840 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$35.24
 

29-08-2017
.40[0.00] pounds
American S: American Shifter
American Shifter 242840 Red Flame Metal Flake Shift Knob with M16 x 1.5 Insert (Black Shift Pattern 2n)
Base Insert Threads :: M16 x 1.5||Design :: Shift Pattern 2n||Design Color :: Black||Shift Knobs Color :: Red||Feature :: High Gloss Finish
Number on catalog scheme: 27
 

Compatible models:

Volvo Penta entire parts catalog list:

MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B

Information:

Power
P = IEwhere P = power in wattsI = current in amperesE = voltage in voltsThis equation for power may also be transposed to: From Ohm's law it is known that E = IR. If this expression for voltage is substituted in the power law, we can derive the additional equation: P = I2RIf we use the equation for current from Ohm's law, I = E/R, the equation for power becomes: *See "Ugly's Electrical Reference" (SEBD0983) for additional information.Resistance
Series Circuits RT = R1 + R2 + R3 + ... RN where RN = resistance in the individual resistorsRT = total resistance in circuitReactance
XL = 2 π f Lwhere XL = inductive reactance in ohms f = frequency in hertzL = inductance in henriesπ = 3.1416 where XC = capacitive reactance in ohms f = frequency in hertzC = capacitance in faradsπ = 3.1416Impedance
where Z = impedance in ohms R = resistance in ohmsXL = inductive reactance in ohmsXC = capacitive reactance in ohmsNote that the impendance will vary with frequency, since both XC and XL are frequency dependent. In practical AC power circuits, XC is often small and can be neglected. In that case, the formula above simplifies to: Transformer Voltage Conversion
where VS = secondary voltage VP = primary voltageNS = number of secondary turnsNP = number of primary turnsPower Factor
In mathematical terms, the power factor is equal to the cosine of the angle by which the current leads or lags the voltage. If the current lags the voltage in an inductive circuit by 60 degrees, the power factor will be 0.5, the value of the cosine function at 60 degrees. If the phase of the current in a load leads the phase of the voltage, the load is said to have a leading power factor; if it lags, a lagging power factor. If the voltage and current are in phase, the circuit has a unity power factor.Equation Summary Diagram
Three Phase Connection Systems:
Electrical Enclosure Protection = IEC
The degrees of protection provided within an electrical enclosure is expressed in terms of the letters IP followed by two numerals. Mechanical protection against impact damage is defined by an optional third numeral. Example: An IP55 enclosure protects its contents against dust and spray from water jets.Reference: DIN 40050 of July 1980, IEC 144 of 1963, IEC 529 of 1976, NF C 20-010 of April 1977Electrical Enclosure Protection - NEMA
Electrical Tables
Table 1 Electrical Formulae Table 2 KV A of AC Circuits Table 3 Copper Wire Characteristics Table 4 Single-Phase AC Motors Full Load Currents in Amperes Table 5 Three-Phase AC Motors - 80% Power Factor Full Load Current in Amperes - Induction-Type, Squirrel Cage and Wound Rotor Table 6 Direct Current Motors Full Load Current in Amperes Table 7 Conduit Sizes for Conductors Table 8 Allowable Current-Carrying Capacities of Insulated Copper Conductors Table 9 Code Letters Usually Applied to Ratings of Motors Normally Started on Full Voltage Table 10 Identifying Code Letters on AC Motors Table 11 Conversion - Heat and Energy Table 12 Approximate Efficiencies - Squirrel Cage Induction Motor Table 13 - Approximate Electric Motor Efficiency to Use in Calculating Input Table 14 Reduced Voltage Starters


Parts protecting Volvo Penta:

840631
 
840631 Protecting casing
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A,
855281
Protecting sleeve
855281 Protecting sleeve
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A,
821053
Protecting bushing
821053 Protecting bushing
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
469456
Protecting ring
469456 Protecting ring
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAM
827596
 
827596 Protecting cap
AQ115A; AQ115B; AQ130, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B
842153
 
842153 Protecting plate
D100A; D100AK; D100B, D70B; D70B PP; D70B K, MD70B; MD70BK; TMD70B
824384
 
824384 Protecting casing
MD70B; MD70BK; TMD70B
837279
 
837279 Protecting plate
MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
Back to top