22295270 Volvo.Penta Pulley


22295270 Pulley Volvo.Penta D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TD520GE; TAD530GE; TAD531GE Pulley
22295270 Pulley Volvo Penta
Rating:
53

Buy Pulley 22295270 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 9
 

Information:


Table 1
Diagnostic Codes for the EFLP Relay
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
1075-5 3666-5 Engine Electric Lift Pump for Engine Fuel Supply : Current Below Normal The Electronic Control Module (ECM) detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is not attempting to power the relay or there is an open circuit.
The ECM has been powered for at least 2 seconds.
There is a low current condition in the EFLP relay circuit or wiring for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the EFLP or power the pump. The EFLP will not operate or the EFLP will operate all the time. The engine will not operate.
1075-6 3666-6 Engine Electric Lift Pump for Engine Fuel Supply : Current Above Normal The ECM detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is attempting to power the relay or the EFLP.
The ECM has been powered for at least 2 seconds.
There is a high current condition in the EFLP relay circuit or a short circuit in the wiring for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the EFLP or power the pump. The EFLP will not operate or the EFLP will operate all the time. The engine will not operate.
The ECM will continue to attempt to activate the relay or power the pump. If the current is OK for 6 seconds, then the diagnostic code will be cleared. The following background information is related to this procedure:The EFLP is used to provide positive fuel pressure to the high-pressure fuel pump. When the keyswitch is turned to the ON position, the ECM will activate the EFLP. If the engine is not running, the ECM will deactivate the EFLP after 2 minutes. The circuit may contain an EFLP relay or the ECM may power the EFLP directly
Illustration 1 g06045505
Schematic for the Electric Fuel Lift Pump (EFLP) without a relay
Illustration 2 g03794110
Schematic for the Electric Fuel Lift Pump (EFLP) with a relay
During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly inspect the connectors between the EFLP relay and the engine ECM. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the EFLP relay.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness and wiring for abrasion and for pinch points from the injectors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position. Do not start the engine.
C. Make a note of any active diagnostic codes.
D. Wait for at least 2 minutes for the Electric Fuel Lift Pump (EFLP) to deactivate. Make a note of any active diagnostic codes.
Diagnostic codes
Result: Diagnostic code 1075-5 or 3666-5 is active when the EFLP is switched off in a circuit with a relay.
Proceed to Test Step 3.
Result: Diagnostic code 1075-6 or 3666-6 is active when the EFLP is switched on in a circuit with a relay.
Proceed to Test Step 5.
Result: Diagnostic code 1075-6 or 3666-6 is active when the EFLP is switched on in a circuit without a relay.
Proceed to Test Step 10.
Result: An active diagnostic code or a recently logged diagnostic code was not displayed. There may be a fault with the switched power circuit for the EFLP. The ECM does not monitor the status of this condition.
Proceed to Test Step 7.
3. Create a Short Circuit at the EFLP Relay
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the Electric Fuel Lift Pump (EFLP) relay.
C. Fabricate a jumper wire that is 150 mm (6 inch) long.
D. Use the jumper wire to connect Test Point 1 to Test Point 2 on the harness connector for the EFLP relay. Refer to Illustration 2.
E. Turn the keyswitch to the ON position. Do not start the engine.
F. Use the electronic service tool to check for an active 1075-6 or 3666-6 diagnostic code.
G. Wait for at least 2 minutes for the EFLP to deactivate. Check for an active 1075-5 or 3666-5 diagnostic code.
H. Turn the keyswitch to the OFF position.
I. Remove the jumper. Leave the connector for the EFLP disconnected.
Open circuit
Result: A 1075-6 or 3666-6 diagnostic code was active with the jumper installed.
Repair: Install a replacement EFLP relay.
Reconnect the connector for the EFLP relay.
Turn the keyswitch to the ON position. Do not start the engine. Check for active diagnostic codes.
Wait for at least 2 minutes for the EFLP to deactivate. Check for active diagnostic codes.
Confirm that the fault has been eliminated.
Result: A 1075-5 or 3666-5 diagnostic code is still active with the jumper installed. There is a fault in the wiring or the ECM.
Proceed to Test Step 4.
4. Check the Wiring Between the ECM and the EFLP Relay for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the EFLP relay. Disconnect the J1 connector from the ECM.
C. Measure the resistance between the following points:
EFLP relay return terminal on the


Parts pulley Volvo Penta:

20592794
 
20592794 Pulley
TAD520GE; TAD720GE; TAD721GE, TD520GE; TAD530GE; TAD531GE
21281782
 
21281782 Pulley
TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TAD550GE; TAD551GE; TAD750GE, TAD750VE; TAD760VE, TD520GE; TAD530GE; TAD531GE, TD520VE; TD720VE
20405705
Pulley
20405705 Pulley
TAD520GE; TAD720GE; TAD721GE, TAD550GE; TAD551GE; TAD750GE, TD520GE; TAD530GE; TAD531GE
20550293
 
20550293 Pulley
TAD520GE; TAD720GE; TAD721GE, TD520GE; TAD530GE; TAD531GE
20771417
 
20771417 Pulley
TAD520VE; TAD720VE; TAD721VE
21425431
 
21425431 Pulley
TAD520VE; TAD720VE; TAD721VE
20460302
 
20460302 Pulley
TAD520VE; TAD720VE; TAD721VE
20460303
 
20460303 Pulley
TAD520VE; TAD720VE; TAD721VE
Back to top