21349962 Volvo.Penta Pump


21349962 Pump Volvo.Penta D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F Pump
21349962 Pump Volvo Penta
Rating:
18

Buy Pump 21349962 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Volvo Penta entire parts catalog list:

D4-180I-B; D4-180I-C; D4-180I-D; D4-180I-E; D4-210A-A; D4-225A-B; D4-210I-A; D4-210I-B; D4-225I-B; D4-225A-C; D4-225A-D; D4-225I-C; D4-225I-
D4-180I-F; D4-225A-F; D4-225I-F; D4-260A-F; D4-260D-F; D4-260I-F; D4-300A-F; D4-300D-F; D4-300I-F
D6-280A-A; D6-280A-B; D6-280A-C; D6-280A-D; D6-280A-E; D6-280I-A; D6-280I-B; D6-280I-C; D6-280I-D; D6-280I-E; D6-310I-A; D6-310A-A; D6-310A-
D6-300A-F; D6-300D-F; D6-300I-F; D6-330A-F; D6-330D-F; D6-330I-F; D6-370A-F; D6-370D-F; D6-370I-F; D6-400A-F; D6-435D-F; D6-435I-F; D6-435I-

Information:


Illustration 1 g01020181
Typical exampleTest Step 1. Check for Connector Damage.
Turn the breaker for the battery to the OFF position.
Turn the ECS to the OFF/RESET position.
Thoroughly inspect the ECM connectors J1/P1 and J2/P2. Inspect all of the other connectors. Refer to the diagnostic functional test Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and for pinch points.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion or of pinch points.Results:
OK - The connectors and wiring are okay. Proceed to Test Step 2.
Not OK - The connectors and/or wiring are not okay.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 2. Check for a Short Circuit in the Wiring Harness.
Disconnect ECM connector J1/P1 and all of the digital sensors.
Measure the resistance between the digital supply P1-35 (A700-OR) and the digital return P1-29 (998-BR) on connector P1.
Measure the resistance between the digital supply P1-35 (A700-OR) and engine ground.
Measure the resistance between the digital return P1-29 (998-BR) and engine ground.Expected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - The resistance is greater than 20,000 Ohms. Proceed to Test Step 3.
Not OK - The resistance is less than 20,000 Ohms.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 3. Check the Digital Supply Voltage at the ECM.
Remove the wire A700-OR from ECM connector P1-35. Install a wire jumper into the socket for wire A700-OR.
Remove the wire 998-BR from ECM connector P1-29. Install a wire jumper into the socket for wire 998-BR.Note: If you remove the sensor common from the ECM an open circuit diagnostic code will be generated for all sensors that use the sensor common. Troubleshoot the original code. Delete the logged diagnostic codes when you are finished.
Turn the breaker for the battery to the ON position.
Turn the ECS to the STOP position on engines with the "EMCP II" panel. Turn the ECS to the SERVICE position on engines with the "EMS II" panel.
Measure the voltage between the wire jumper in P1-35 and the wire jumper in P1-29.
Turn the ECS to the OFF/RESET position.
Remove the wire jumpers and reconnect all wires. Reconnect ECM connector J1/P1.Expected Result:The supply voltage is 8.0 0.4 VDC.Results:
OK - The supply voltage is 8.0 0.4 VDC. The digital sensor supply is producing the correct voltage. Proceed to Test Step 4.
Not OK - The supply voltage is not 8.0 0.4 VDC. The digital sensor is not producing the correct voltage.Repair: Perform the diagnostic functional test Troubleshooting, "Electrical Power Supply". Stop.Test Step 4. Check the Digital Sensor Supply Voltage at the Sensor Connector.
Turn the ECS to the STOP position on engines with the "EMCP II" panel. Turn the ECS to the SERVICE position on engines with the "EMS II" panel.
Measure the digital sensor supply voltage between the digital supply terminal-A (A700-OR) and the digital return terminal-B (998-BR) of all the digital sensors.Note: If the sensor is disconnected from the harness, an open circuit diagnostic code will be generated for that sensor. Troubleshoot the original code. Delete the logged diagnostic codes when you are finished.
Turn the ECS to the OFF/RESET position.Expected Result:The supply voltage is 8.0 0.4 VDC.Results:
OK - The supply voltage is 8.0 0.4 VDC at all of the digital sensor connectors. Proceed to Test Step 5.
Not OK - The supply voltage is not 8.0 0.4 VDC. There is an open circuit in the harness or connectors.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 5. Check the Digital Sensors for Short Circuits.
Disconnect all of the digital sensors.
Turn the ECS to the STOP position on engines with the "EMCP II" panel. Turn the ECS to the SERVICE position on engines with the "EMS II" panel.Note: If the sensor is disconnected from the harness, an open circuit diagnostic code will be generated for that sensor. Troubleshoot the original code. Delete the logged diagnostic codes when you are finished.
Connect one digital sensor at a time.
Measure the digital sensor supply voltage between the digital supply terminal-A (A700-OR) and the digital return terminal-B (998-BR) at a different sensor connector. Repeat these steps with all of the digital sensors.
Turn the ECS to the OFF/RESET position.Expected Result:The supply voltage is 8.0 0.4 VDC.Results:
OK - The supply voltage is 8.0 0.4 VDC. The digital sensor supply is correct. The harness and sensors are okay. Repair: The problem may be intermittent. If the problem is intermittent, perform the diagnostic functional test Troubleshooting, "Inspecting Electrical Connectors". Stop.
Not OK - The supply voltage is not 8.0 0.4 VDC when a sensor is reconnected. The sensor may be internally shorted.Repair: Temporarily install a new sensor. Ensure that the problem is no longer present. Reinstall the old sensor. If the problem returns, replace the sensor. Stop.


Parts pump Volvo Penta:

844015
 
844015 Pump housing
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131
21317314
 
21317314 Pump
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
3583737
 
3583737 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D6-280A-A; D6-280A-B; D6-280A-C
888154
Pump
888154 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D6-280A-A; D6-280A-B; D6-280A-C
888155
Pump
888155 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D6-280A-A; D6-280A-B; D6-280A-C
22381257
 
22381257 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
21349964
 
21349964 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
22381259
 
22381259 Pump
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
Back to top