Information:
Park the machine on a hard, level surface. Lower the scraper bowl to the ground and engage the parking brake. Chock the wheels in order to prevent the machine from moving.
Put identification marks on all lines, hoses, wires and tubes for installation purposes. Plug all lines, hoses and tubes. This helps prevent fluid loss and contamination of the fluid system.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide", for tools and supplies suitable to collect and contain fluids in Caterpillar machines.Dispose of all fluids according to local regulations and mandates.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Reclaim the refrigerant from the cooling system.
Illustration 1 g00497298
Remove seven bolts (1) and the washers that secure bottom access panel (2) to the frame. Remove bottom access panel (2) from the frame.
Illustration 2 g00497299
Loosen two retaining nuts (3) . Disconnect two hoses (4) from refrigerant accumulator (5) .
Remove two bolts (6) and the washers that secure bracket (7) to the frame. Remove bracket (7) and refrigerant accumulator (5) from the frame.
Loosen two hose clamps (8) . Remove refrigerant accumulator (5) from bracket (7) .Installation Procedure
Clean all parts and inspect all parts. If any parts are worn or damaged, use new Caterpillar parts for replacement.
Illustration 3 g00497299
Position refrigerant accumulator (5) to bracket (7) . Install two hose clamps (8) around refrigerant accumulator (5) and through bracket (7) .
Position bracket (7) on the frame. Install two bolts (6) and the washers that secure bracket (7) to the frame.
Connect two hoses (4) to refrigerant accumulator (5) . Tighten two retaining nuts (3) .
Illustration 4 g00497298
Position bottom access panel (2) on the frame. Install seven bolts (1) and the washers that secure bottom access panel (2) to the frame.
Personal injury or death can result when charging an air conditioning system with a liquid.The compressor will pump the refrigerant back into the charging cylinder with the possibility of rupturing (exploding) the cylinder.Do not operate the engine when charging with a liquid. Never charge liquid or gas through the discharge (high side of the system) with the engine running.Keep all other personnel either away from the machine or where they can be seen when working on the air conditioning system.
Evacuate the air conditioning system and charge the air conditioning system. Refer to Operation and Maintenance, SEBU7143. Refer to Service Manual, SENR5664, "Air Conditioning And Heating Systems With R-134a Refrigerant" .
Parts radiator Volvo Penta:
3829280
3829280 Radiator
TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630V; TWD1630V, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TD121G-87; TWD1210V; TWD1211V, TD610G; TWD610G; TD710G, TWD1620G; TWD1630G; TAD1630G, TWD610P; TWD610PB; TWD710P
344753
344753 Radiator cap
D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D42A; D42A PP, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, TAD1030G; TD1010G; TWD1010G, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD71B; TAMD73P-A; TAMD73WJ-A, TD100CHC;
866092
866092 Radiator
TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD100G-87; TD1030VE; TAD1030V, TD610G; TWD610G; TD710G, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P
864892
864892 Radiator
TAD1030G; TD1010G; TWD1010G, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TD121G-87; TWD1210V; TWD1211V, TD610G; TWD610G; TD710G, TD61A; TD61AW; TD61ACE
863061
848837
848837 Radiator hose
TD610G; TWD610G; TD710G, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P
848371
848371 Radiator hose
TD610G; TWD610G; TD710G, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V
848834