20862761 Volvo.Penta Seal


20862761 Seal Volvo.Penta TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1360VE, TAD1361VE, TAD1363VE Seal
20862761 Seal Volvo Penta
Rating:
43

Buy Seal 20862761 Volvo Penta genuine, new aftermarket parts with delivery

Volvo Penta entire parts catalog list:

TAD1340VE; TAD1341VE; TAD1342VE; TAD1343VE; TAD1344VE; TAD1345VE; TAD1360VE; TAD1361VE; TAD1362VE; TAD1363VE; TAD1364VE; TAD1365VE; TAD1360-
TAD1341GE; TAD1342GE; TAD1343GE; TAD1344GE; TAD1345GE; TAD1350GE; TAD1351GE; TAD1352GE; TAD1353GE; TAD1354GE; TAD1355GE
TAD1350VE
TAD1360VE
TAD1361VE
TAD1363VE

Information:


Illustration 1 g06277215The fuel flows from the main gas supply through a knock-down regulator. A knock-down regulator is a second regulator that is needed when the gas supply pressure is too high for a single regulator to manage.From knock-down regulator, the fuel flows to the fuel filter. Usually, the fuel filter is a component of the design at the particular site. The customer is responsible for supplying clean, dry fuel to the engine. The fuel filter may be supplied by Caterpillar or by the customer. To prevent particles from entering the engine, a 1 micron filter is recommended. Select a filter that is properly sized for the required gas pressure.For installation of the fuel filter, the recommended location is close to the engine before the engine gas pressure regulator. Pressure gauges in the gas lines on each side of the fuel filter are recommended to monitor the filter differential pressure. A manual shutoff valve in the gas line before the fuel filter will facilitate servicing of the filter.The filtered fuel flows to the Gas Shutoff Valve (GSOV). The GSOV may be supplied by Caterpillar or by the customer. The solenoid for the GSOV may be connected to engine wiring harness or to a harness that is supplied by the customer. In either case, the customer may install a switch that can interrupt the circuit.The control system is configured for a GSOV that is energize-to-run. This statement means that the GSOV must be energized in order for the engine to run. The GSOV may be energized by the customer equipment or by the ECM. When the GSOV is energized, the valve opens and the fuel flows to the engine. When the control system shuts down the engine, the voltage is removed from the solenoid. The valve closes and the fuel is shut off.The fuel flows through the GSOV to the gas pressure regulator.The regulator may be supplied by Caterpillar or by the customer.The required fuel pressure stability is 1.7237 kPa ( 0.25 psi).A regulated pressure of 10.3 to 17.2 kPa (1.5 to 2.5 psi) is recommended.Less gas pressure may result in reduced power. More gas pressure may result in instability.The fuel flows to the electronically controlled fuel metering valve . The ECM issues a command signal to the fuel metering valve via the CAN data link. The fuel metering valve regulates the flow of fuel to the engine.The fuel metering valve controls the volume of fuel that flows to an adapter in the air inlet elbow. The inlet air that is necessary for combustion enters through the air inlet elbow. The air/fuel mixture enters turbocharger compressor.The compressed air/fuel mixture flows to the aftercooler. The temperature of the compressed air/fuel mixture is reduced in the aftercooler resulting in an increased density of the air/fuel mixture, resulting in more efficient combustion.The cooled air/fuel mixture flows to the electronically controlled throttle. The ECM issues a command signal to the actuator for the throttle via the CAN data link. The signal is based on the desired engine speed. The throttle controls the volume of the air/fuel mixture that flows through the intake manifold.The manifold distributes the air/fuel mixture to the cylinders for combustion.


Parts seal Volvo Penta:

1608766
 
1608766 Seal
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
8159012
 
8159012 Seal
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-
9148107
 
9148107 Seal
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
1079234
 
1079234 Seal
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
20979871
Seal
20979871 Seal
D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1360VE, TAD1361VE, TAD136
20805850
Seal
20805850 Seal
D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1351VE; TAD1352VE; TAD135
22250515
 
22250515 Seal
1372, TAD1140VE; TAD1141VE; TAD1142VE, TAD1150VE; TAD1151VE; TAD1152VE, TAD1170VE; TAD1171VE; TAD1172VE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1350VE, TAD1360VE, TAD1361VE, TAD1363VE, TAD1371VE; TAD1372VE; TAD1373VE
22250514
 
22250514 Seal
1372, TAD1140VE; TAD1141VE; TAD1142VE, TAD1150VE; TAD1151VE; TAD1152VE, TAD1170VE; TAD1171VE; TAD1172VE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1350VE, TAD1360VE, TAD1361VE, TAD1363VE, TAD1371VE; TAD1372VE; TAD1373VE
Back to top