21117497 Volvo.Penta Seal


21117497 Seal Volvo.Penta D12D-A MH; D12D-B MH; D12D-C MH Seal
21117497 Seal Volvo Penta
Rating:
78

Buy Seal 21117497 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 7
 

Compatible models:

Volvo Penta entire parts catalog list:

D12D-A MH; D12D-B MH; D12D-C MH; D12D-E MH; D12D-G MH; D12C-A MP; D12D-A MP; D12D-B MP; D12D-C MP; D12D-D MP; D12D-E MP; D12D-F MP; D12D-G M

Information:


Caterpillar recommends that the coolant mixture contain a minimum of 30% Caterpillar Antifreeze, or equivalent. Liquid supplemental coolant additive must be added to cooling system when not using Caterpillar Antifreeze, which contains proper additive.Never add coolant water to an overheated engine, engine damage can result. Allow the engine to cool first.All water is corrosive at engine operating temperature. The cooling system should be protected with a 3% to 6% concentration of liquid supplemental coolant additive at all times, regardless of the concentration of antifreeze.Excessive supplemental coolant additive greater than the recommended 6%, together with concentrations of antifreeze greater than 60% can cause deposits to form and can result in radiator tube blockage, overheating, and/or water pump seal damage.DO NOT use Dowtherm 209 Full-Fill coolant.Do not use liquid supplemental coolant additive or elements or antifreeze with Dowtherm 209 Full-Fill coolant. Dowtherm 209 Full-Fill coolant is not compatible with other antifreeze and coolant mixtures.If the engine is to be stored in, or shipped to, an area with freezing temperatures, the cooling system must be protected to the lowest expected outside (ambient) temperature.The engine cooling system is normally protected to -20°F (-28°C) with Caterpillar Antifreeze, when shipped from the factory unless special requirements are defined.
Check the specific gravity of the antifreeze solution frequently in cold weather to ensure adequate freeze protection.Clean the cooling system if it is contaminated, if the engine overheats, or if foaming is observed in the radiator.Coolant should be drained, the system cleaned and new coolant added at PM Level 2 (every 3000 service hours or every two years). When not using Caterpillar Antifreeze and supplemental coolant additive asrecommended, the drain period must be shortened to 1500 service hours or every year.Filling at over 5 U.S. gal (20 L) per minute can cause air pockets in the cooling system.After draining and refilling the cooling system, operate the engine with the radiator filler cap removed until the coolant reaches normal operating temperature and the coolant level stabilizes. Add coolant mixture as necessary to fill the system to the proper level.Operate with a thermostat in the cooling system all year-round. Cooling system problems can arise without a thermostat.Refer to "Know Your Cooling System," form SEBD0518 and "Coolant and Your Engine" form SEBD0970, for more detailed specifications.Coolant Water
Hard water, or water with high levels of calcium and magnesium ions, encourages the formation of insoluble chemical compounds by combining with cooling system additives such as silicates and phosphates.The tendency of silicates and phosphates to precipitate out-of-solution increases with increasing water hardness. Hard water, or water with high levels of calcium and magnesium ions encourages the formation of insoluble chemicals, especially after a number of heating and cooling cycles.Caterpillar prefers the use of distilled water or deionized water to reduce the potential and severity of chemical insolubility. Using water that meets the minimum acceptable water requirement may not prevent drop-out of these chemical compounds totally, but should minimize the rate to acceptable levels.To determine water characteristics, contact local water department, agricultural agent or an independent laboratory to perform the testing service. Two companies are listed below. However, there are others who are qualified to provide this service.L.O.C.C. Corp.
905 Bayshore Drive
Coos Bay, OR 97420
Ph. (503) 267-4904
NALCO Chemical Co.
Naperville Technical Center
One Nalco Center
Naperville, IL 60566
Attn: Sample Receiving
Ph. (312) 961-9500
Antifreeze
Caterpillar recommends that the coolant mix contain a minimum of 30% Caterpillar Antifreeze, or equivalent and acceptable water to maintain an adequate water pump cavitation temperature for efficient water pump performance.Premix coolant solution to provide protection to the lowest expected outside (ambient) temperature. Pure undiluted antifreeze will freeze at -10°F (-23°C).Only use a greater concentration (above 30%) of Caterpillar Antifreeze as needed for anticipated outside (ambient) temperatures. Do not exceed a coolant mixture of 60% antifreeze to water since a concentration above 60% antifreeze will reduce the engine's freeze protection and increase the possibility of deposit formation in the cooling system.
Use Caterpillar Antifreeze or ASTM D4985-89 (GM Specification 6038-M) Antifreeze. However, supplemental coolant conditioner must be added to these coolants. See topic "Supplemental CoolantAdditive (Conditioner)" in this manual for further information.Caterpillar Antifreeze is available through your Caterpillar dealer in quantities that follow. Most commercial antifreezes are formulated for gasoline engine applications and will, therefore, have high silicate content. Caterpillar Antifreeze is formulated with a low silicate content and the proper coolant additives for heavy duty diesel engines. Caterpillar does not recommend use of high silicate antifreeze in the 3176 engine.ASTM D4985-89 (GM Specification 6038-M) is a low silicate antifreeze, but supplemental coolant additive must be added.The major advantages of Caterpillar Antifreeze are:* Significantly reduces water pump seal leakage problems caused by excessive concentration of chemical additives.* There is no need to add supplemental coolant additive (conditioner) on initial fill, which must be done with current commercially available antifreezes.* High silicate antifreezes used with a supplemental coolant additive can cause a build-up of solids over a period of time which can cause plugging, loss of heat transfer, and water pump seal damage.Make proper antifreeze additions.
Adding pure antifreezes as a makeup solution for cooling system top-off is an unacceptable practice. It increase the concentration of antifreeze in the cooling system which increases the concentration of dissolved solids and undissolved chemical inhibitors in the cooling system. Add antifreeze mixed with acceptable water to the same freeze protection as your cooling system. Pure, undiluted antifreeze will freeze at -10°F (-23°C).Use the chart below to assist in determining the concentration of Caterpillar Antifreeze to use.
5P0957 Coolant Tester (°F) or 5P3514 Coolant Tester (°C)Both are available at your Caterpillar dealer.Check the coolant solution frequently in cold weather for glycol concentration with the 5P0957 or 5P3514 Coolant Tester to ensure adequate protection. Both testers are identical except temperature scale. They give immediate, accurate readings and can be used for antifreeze/coolants that contain ethylene or propylene glycol.If propylene glycol based antifreeze is used, DO NOT allow concentration greater than a 50/50 antifreeze to water mixture. The measurement of freeze protection must be made with a refractive-type tester (Cat 5P0957 or 5P3514) rather than a hydrometer-type,


Parts seal Volvo Penta:

1608766
 
1608766 Seal
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
862532
 
862532 Seal
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P
862520
Seal
862520 Seal
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A,
862524
 
862524 Seal
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A,
8159012
 
8159012 Seal
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-
3830184
Seal
3830184 Seal
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
9148107
 
9148107 Seal
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
1079234
 
1079234 Seal
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
Back to top