814356 Seal Volvo.Penta
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131
Seal
Price: query
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Shocks for Polaris Ranger Crew 500 2011-2013 Front & Rear Gas Shocks by Race-Driven
Race-Driven Brand New Race-Driven High Quality Gas Shocks || Aftermarket shock engineered and built to the exact dimensions of OEM || Designed to meet or exceed original equipment quality standards for long lasting performance. || Fits: 2011 2012 2013 Polaris Ranger Crew 500
Race-Driven Brand New Race-Driven High Quality Gas Shocks || Aftermarket shock engineered and built to the exact dimensions of OEM || Designed to meet or exceed original equipment quality standards for long lasting performance. || Fits: 2011 2012 2013 Polaris Ranger Crew 500
Loczek Accessories 832846 Water Inlet Hose Connector Connection for Vo-l-vo Penta Sterndrive Engines 270 280 290 814356 18-2278
Loczek Brand new, high quality, corrosion resistant, reliable replacement parts || Made of high quality iron material, durable. || High quality and long life replacement parts accessories || Each product undergoes quality inspection before leaving the factory. || Stable performance and high reliability. || Package Included: || water hose connector and rubber seal x 1 || Condition:Brand New || Replaces OEM Part #:832846 .814356 || Replaces Sierra #:18-2278
Loczek Brand new, high quality, corrosion resistant, reliable replacement parts || Made of high quality iron material, durable. || High quality and long life replacement parts accessories || Each product undergoes quality inspection before leaving the factory. || Stable performance and high reliability. || Package Included: || water hose connector and rubber seal x 1 || Condition:Brand New || Replaces OEM Part #:832846 .814356 || Replaces Sierra #:18-2278
Compatible models:
230A; 230B; 250A
251A
430; 430A; 430B
500; 500A; 501A
571A
740A; BB740A
AD30A; AQAD30A; MD30A
AD31D; AD31D-A; AD31XD
AD31L-A; AD31P-A; AD41L-A
AD41D; D41D; TAMD41D
AQ115A; AQ115B; AQ130
AQ120B; AQ125A; AQ140A
AQ125B
AQ131A; AQ131B; AQ131C
AQ145A; BB145A
AQ145B
AQ151A; AQ151B; AQ151C
AQ171A; AQ171C
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C
AQ200D; AQ200F; 280B
AQ205A; AQ205LB
AQ211A; DP-A; SP-A
AQ225D; AQ225E; AQ225F
AQ231A; AQ231B; AQ231LB
AQ260A; AQ260B; BB260A
AQ271A; AQ271B; AQ271C
AQ290A
AQ311A; AQ311B
DP-C1; DP-D1; DP-S
DP-E; SP-E; TSK DP-E
DPX-R; DPX-R 1.47; DPX-R 1.51
DPX-S; DPX-S1; DPX-S 1.59
KAD42A; KAMD42A; HS1A
KAD42B; KAMD42B; TAMD42B
KAD42P-A; KAMD42P-A; HS1A
MD21B; AQD21B
MD31A; TMD31A; TMD31B
MD31A; TMD31B; TAMD31B
MD40A; TMD40A; TMD40B
TMD41A; TMD41B; D41A
TMD41B; D41B; TAMD41B
Volvo.Penta
Volvo Penta entire parts catalog list:
- Intermediate Housing » 814356
- Intermediate Housing: SPA
- Intermediate Housing: SPA-1
- Intermediate Housing
- Repair Kits Drive Unit
- Repair Kit, Astern Lever
- Intermediate Housing: SPA
- Intermediate Housing: SPA-1
- Repair Kits Drive Unit
- Repair Kit, Astern Lever
- Intermediate Housing: SPA
- Intermediate Housing: SPA-1
- Intermediate Housing: SPA-2
- Intermediate Housing
- Intermediate Housing: DPA
- Intermediate Housing: DPA-1
- Intermediate Housing
- Intermediate Housing
- Repair Kits Duoprop Drive Unit
- Repair Kits Drive Unit
- Repair Kit, Astern Lever Drive Unit
- Intermediate Housing: SPA
- Intermediate Housing: SPA-1
- Intermediate Housing: SPA-2
- Intermediate Housing: DPA
- Intermediate Housing: DPA-1
- Intermediate Housing
- Repair Kits Drive Unit
- Repair Kits Duoprop Drive Unit
- Repair Kit, Astern Lever
- Intermediate Housing: SPA
- Intermediate Housing: SPA-1
- Intermediate Housing: SPA-2
- Repair Kits Drive Unit
- Repair Kit, Astern Lever
- Intermediate Housing: DPB
- Intermediate Housing: DPB-1
- Intermediate Housing
- Repair Kits Duoprop Drive Unit
- Repair Kit, Astern Lever
- Intermediate Housing AQ Drive Unit 280
- Intermediate Housing AQ Drive Unit 290
- Intermediate Housing
- Intermediate Housing
- Repair Kits AQ Drive Unit 280, 290
- Repair Kits Duoprop Drive Unit
AD31L-A; AD31P-A; AD41L-A; AD41P-A; D41L-A; TAMD31L-A; TAMD31M-A; TAMD31P-A; TAMD31S-A; TAMD41H-A; TAMD41H-B; TAMD41P-A; TAMD41L-A; TAMD41M-A
AD41D; D41D; TAMD41D; TMD41D; HS1A
AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
- Intermediate Housing AQ Drive Unit 250
- Intermediate Housing AQ Drive Unit 270
- Intermediate Housing AQ Drive Unit 270T
- Intermediate Housing AQ Drive Unit 280
- Intermediate Housing AQ Drive Unit 280T
- Repair Kits AQ Drive Unit 250, 270, 280
AQ125B
AQ131A; AQ131B; AQ131C; AQ131D
- Intermediate Housing: DRIVE 275
- Intermediate Housing: DRIVE 275A
- Intermediate Housing
- Intermediate Housing
- Intermediate Housing
- Repair Kits Drive Unit
AQ145B
AQ151A; AQ151B; AQ151C
AQ171A; AQ171C
AQ175A
- Intermediate Housing: DRIVE 280
- Intermediate Housing: DRIVE 280L
- Intermediate Housing AQ Drive Unit 290
- Repair Kit AQ Drive Unit
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C; AQ225D; AQ255A; AQ255B
AQ200D; AQ200F; 280B; 290A; 290DP
- Intermediate Housing: DRIVE 280
- Intermediate Housing: DRIVE 280L
- Intermediate Housing AQ Drive Unit 290: 290
- Intermediate Housing AQ Drive Unit 290: B
- Intermediate Housing
- Repair Kit AQ Drive Unit
- Repair Kits Duoprop Drive Unit
AQ211A; DP-A; SP-A; 290A
- Intermediate Housing
- Intermediate Housing
- Intermediate Housing
- Intermediate Housing
- Repair Kit AQ Drive Unit
- Repair Kits Duoprop Drive Unit
Information:
Illustration 1 g00840097
SchematicTest Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J3/P3 machine connector, and all other connectors in the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets should be completely inserted and coupled. The harness and wiring should be free of corrosion, abrasion, and pinch points. All connections and grounds should be tight and free of corrosion.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Resistance through the Solenoid
Turn the keyswitch to the OFF/RESET position.
Disconnect the push/pull solenoid for the variable pitch fan.
Measure the resistance between J160:1 (Push Solenoid) and J160:2 (Digital Return).
Measure the resistance between J160:4 (Pull Solenoid) and J160:3 (Digital Return).Expected Result:Resistance should be 25 5 Ohms.Results:
OK - The push/pull solenoid for the variable pitch fan has the correct resistance. Proceed to Test Step 3.
Not OK - The push/pull solenoid for the variable pitch fan is faulty.Repair: Install a new push/pull solenoid for the variable pitch fan.Verify that the repair eliminates the problem.STOPTest Step 3. Check the Status of the Manual Purge Switch on ET
Connect ET to the service tool connector.
Turn the keyswitch to the ON position.
Observe the status for "Engine Fan Manual Purge Switch" on ET while you operate the switch.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switch should be "On" when the switch is depressed. The status should read "Off" when the switch is released.Results:
OK - The manual purge switch is working properly. Proceed to Test Step 5.
Not OK - The ECM does not recognize the input from the manual purge switch. Proceed to Test Step 4.Test Step 4. Check the Manual Purge Switch
Turn the keyswitch to the OFF/RESET position.
Disconnect the J161/P161 manual purge switch connector.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the released position.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the depressed position.Expected Result:There should be no continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the released position. There should be continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the depressed position.Results:
OK - There is no continuity when the switch is in the released position. There is continuity when the switch is in the depressed position. Proceed to Test Step 5.
Not OK - There is a problem with the manual purge switch.Repair: Replace the manual purge switch with a new switch.Verify that the repair eliminates the problem.STOPTest Step 5. Check for Shorts in the Harness for the Variable Pitch Fan
Illustration 2 g00840099
The P1 ECM connector
Disconnect the J1/P1 ECM connector.
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between P1:22 (Manual Purge Switch) and chassis ground.
Measure the resistance between P1:28 (Pull Solenoid) and chassis ground.
Measure the resistance between P1:34 (Push Solenoid) and chassis ground.
Measure the resistance between P1:22 (Manual Purge Switch) and P1:29 (Digital Return).
Measure the resistance between P1:28 (Pull Solenoid) and P1:29 (Digital Return).
Measure the resistance between P1:34 (Push Solenoid) and P1:29 (Digital Return).
Measure the resistance between P1:22 (Manual Purge Switch) and P1:28 (Pull Solenoid).
Measure the resistance between P1:22 (Manual Purge Switch) and P1:34 (Push Solenoid).
Measure the resistance between P1:28 (Pull Solenoid) and P1:34 (Push Solenoid).Expected Result:The resistance for each measurement should be greater than 20,000 Ohms.Results:
OK - There are no shorts in the harness. Proceed to Test Step 6.
Not OK - There is a short between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.STOPTest Step 6. Check for Open Circuits in the Harness for the Variable Pitch Fan
Illustration 3 g00840099
J1/P1 breakout
Turn the keyswitch to the OFF/RESET position and disconnect the J1/P1 ECM connector.
Use a suitable piece of wire to short P1:22 (Manual Purge Switch) and P1:29 (Digital Return).
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between J161:B (Manual Purge Switch) and J161:C (Digital Return).
Use a suitable piece of wire to short P1:28 (Pull Solenoid) and P1:29 (Digital Return).
Measure the resistance between P160:4 (Pull Solenoid) and P160:3 (Digital Return).
Use a suitable piece of wire to short P1:34 (Push Solenoid) and P1:29 (Digital Return).
Measure the resistance between P160:1 (Push Solenoid) and P160:2 (Digital Return).
Remove all shorts and reconnect all connectors.Expected Result:The resistance should be less than 10 Ohms.Results:
OK - The wiring harness for the variable pitch fan is operating correctly. The ECM is not sending the correct signal to the push/pull solenoid for the variable pitch fan.Repair: Verify your results. Replace the ECM. Refer to Troubleshooting, "Replacing the ECM" before replacing the ECM.Verify that the repair eliminates the problem.STOP
Not OK - There is an open circuit between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOP
Parts seal Volvo Penta:
828526
828526 Seal
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MB10A, MD11; MD11C; M
828527
828527 Seal
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MB10A, MD11; MD11C; M
862520
862520 Seal
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A,
862524
862524 Seal
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MH; D12D-B MH; D12D-C MH, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A,
872238
872238 Seal flange kit
430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, DP-G; TSK DP-G, DPX-A; TSK DPX-A, DPX-R; DPX-R 1.47; DPX-R 1.51, DPX-S; DPX-S1; D
463416
944151
944152