991010 Volvo.Penta Shim


991010 Shim Volvo.Penta IPS2-A, IPS2-B, IPS2-C, IPS20-D Shim
991010 Shim Volvo Penta
Rating:
53

Buy Shim 991010 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$70.95

07-01-2025
51.0[22.95] pounds
US: Fix_My_Toys
Gravely 1.00" ID x 5.75" OD Double Pulley 07329200
Gravely OEM Ariens Part Number: 07329200, Replaces: 07329267, 07300031 || Fits Ariens: Max Zoom 48 HD 991073, Max Zoom 48 991085, PM 144Z 992312 || Fits Gravely: 991009 PM144XDZ; 991026 PM144MXDZ; 991010 PM148XDZ; 991027 PM148MXDZ; 991011 PM152XDZ; 991028, 991031 PM152MXDZ; 991013 PM160XDZ; 991015, 991032 PM144M; 991016, 991029 PM148M; 991017, || Fits Gravely: 991035, 991058 PM44Z; 991036, 991059 PM48Z; 991060, 991062 PM148i; 991061, 991063 PM152i; 991064, 991067 PM160i; 991050, 991052, 991090, 991098, 991107, 991111 ZT HD 44; 991051, 991053, || Fits Gravely: 991076, 991079, 991095, 991102, 991115, 991119, 991122, 991127, 991128, 991131, 991134, 991137, 991300, 991303 Pro-Turn 148; 991077, 991080, 991096, 991103 Pro-Turn 152; 991078 Pro Turn
$76.76
 

08-09-2022

-: -
Replacement Deck Belt for Gravely 07200025 48" Zero Turn PM44Z PM48Z ZT48HD
Replaces OEM# Ariens 07200025 || Fits Models: Ariens / Gravely ZERO-TURN: 991010 PM148 XDZ (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991021 PM148H (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991027 PM148Z XDZ (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991029 PM148M (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991036 PM48Z (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991051 ZT2648HD (Primary 48" Deck) || Fits Models: Ariens / Gravely ZERO-TURN: 991053 ZT2348 (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991058 PM44Z (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991059 PM48Z (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991068 ZT48HD (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991073 MAX ZOOM 48 (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991082 ZT48HD (Primary 48" Deck) || Fits Models: Ariens / Gravely ZERO-TURN: 991085 MAX ZOOM 48 (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991089 PRO44 (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991099 ZT48HD (Primary 48" Deck) Ariens / Gravely ZERO-TURN: 991106 PRO44 (Primary 48" Deck 114.5" Belt) || Specifications: .625" X 115.5" Double Angled
$46.99
 

07-04-2024

US: EPR Distribution
PTO Deck Belt Replacement for Ariens 48" PM148, ZT2348, ZT48HD, Max Zoom 48, PRO44, 07200025
A&I Products REPLACES OEM MPN#'s: Ariens 07200025 || COMPATIBLE WITH MODELS: 991010 PM148 XDZ (Primary 48" Deck), 991021 PM148H (Primary 48" Deck), 991027 PM148Z XDZ (Primary 48" Deck) and others || SPECIFICATIONS - .625" X 115.5" Double Angled || ***Please view specifications and reference below before purchasing***
Number on catalog scheme: 23
 

Compatible models:

Volvo Penta entire parts catalog list:

Information:


Table 1
Diagnostic Codes Table
CDL Code and Description Comments
94–3
Fuel Delivery Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
94–4
Fuel Delivery Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
100-3
Engine Oil Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
100-4
Engine Oil Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
101-3
Crankcase Air Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
101-4
Crankcase Air Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
274-3
Atmospheric Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
274-4
Atmospheric Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
460-3
Fuel Pressure Sensor - After Fuel Filter : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
460-4
Fuel Pressure Sensor - After Fuel Filter : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1785-3
Intake Manifold Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1785-4
Intake Manifold Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1835-3
Auxiliary Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1835-4
Auxiliary Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1924-3
Engine Intake Valve Actuation System Oil Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged. The value of the parameter is set to a gauge pressure.
1924-4
Engine Intake Valve Actuation System Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged. The value of the parameter is set to a gauge pressure.
Illustration 1 g06164330Probable Causes
Codes
Short circuit
Open circuit
Supply voltage
Wiring
DPF components
Electrical connectorsRecommended Actions
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Establish communication between Cat® Electronic Technician (ET) and the ECM . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Turn the keyswitch to ON.
C. Look for "-3", or "-4" active or logged codes.
Codes
Result: A -3 diagnostic code is active.
Proceed to Test Step 2.
Result: A -4 diagnostic code is active.
Proceed to Test Step 3.
2. Create a Short at the Sensor Connector
A. Use a test lamp to create a short between terminal 3 (signal) and terminal 2 (sensor return) at the sensor connector.
B. Turn the keyswitch to ON.
C. Monitor the diagnostic codes on Cat ET. Check for an active -4 diagnostic code for the suspect sensor.
D. Turn the keyswitch to OFF.
Short circuit
Result: A -4 diagnostic code does not become active for the suspect sensor.
Proceed to Test Step 4.
Result: A -4 diagnostic code became active after creating the short at the sensor connector. The wiring is OK.
Repair: Replace the sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Create an Open at the Suspect Sensor Connector
A. Turn the keyswitch to OFF.
B. Disconnect the sensor connector of the suspect sensor with the active -4 diagnostic code.
C. Turn the keyswitch to ON.
D. Monitor the diagnostic codes on Cat ET. Check for an active -3 diagnostic code for the suspect sensor.
E. Turn the keyswitch to OFF.
Open circuit
Result: A -3 diagnostic code did not become active after disconnecting the sensor.
Proceed to Test Step 4.
Result: A -3 diagnostic code became active after disconnecting the sensor. The wiring is OK.
Repair: Replace the sensor.
If the problem is not resolved, proceed to Test Step 4.
4. Check the 5 VDC Supply Voltage at the Sensor Connector
A. Turn the keyswitch to ON.
B. Measure the voltage between pin 1 and pin 2 at the suspect sensor.
5.0 0.2 VDC
Result: The supply voltage is OK.
Repair: Connect the sensor.
Proceed to Test Step 5
Result: The supply voltage is NOT OK. There is a short in the harness to the battery.
Repair: Repair the wiring


Parts shim Volvo Penta:

3884688
 
3884688 Shim
IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
3884687
 
3884687 Shim
IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
3884686
 
3884686 Shim
IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
3884189
 
3884189 Shim
IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
3884190
 
3884190 Shim
IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
21211765
 
21211765 Shim
IPS-A, IPS-B, IPS-C, IPS-D, IPS-E, IPS-F, IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
21157128
 
21157128 Shim
IPS-A, IPS-B, IPS-C, IPS-D, IPS-E, IPS-F, IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
991097
 
991097 Shim
IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D
Back to top