20460064 Volvo.Penta Six point screw


20460064 Six point screw Volvo.Penta D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TD420VE; TAD420VE; TAD620VE, TD520GE; TAD530GE; TAD531GE, TD520VE; TD720VE Six
20460064 Six point screw Volvo Penta
Rating:
58

Buy Six point screw 20460064 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 17
 

Volvo Penta entire parts catalog list:

Information:


Table 1
Alternative     Default    
"Cab Switches", "Remote Switches", and "Remote Throttle"     "OFF"    "PTO Top Engine Limit"
The "PTO Top Engine Limit" is the top engine limit that is available by using a PTO on/off circuit that is connected to input 1 (J1/P1:56). Note: The "PTO Configuration" must be programmed to "Cab Switches", "Remote Switches", or "Remote Throttle" before this parameter can be programmed.
Table 2
Minimum     Maximum     Default    
700     TEL rpm     TEL rpm    "PTO Engine RPM Set Speed"
The "PTO Engine RPM Set Speed" is the engine rpm that is allowed by the ECM when the PTO on/off circuit is on and the set switch is actuated.If the "PTO to Set Speed" parameter is programmed to "YES", the engine will proceed to this speed whenever the PTO on/off circuit is turned on.Note: "PTO Configuration" must be programmed to "Cab Switches" or "Remote Switches" for this parameter to function.This parameter must be programmed higher than the programmed low idle. If the "PTO to Set Speed" is programmed to a higher value than the "PTO Top Engine Limit", the set speed will be limited by the lower "PTO Top Engine Limit".For one rpm set speed above low idle, program the "PTO Top Engine Limit" to the same rpm as the "PTO Engine RPM Set Speed".For two rpm set speeds above low idle, program this parameter to some intermediate value between the low idle and the "PTO Top Engine Limit".Place the PTO on/off switch to the ON position. Toggle the set switch once in order to cause the rpm to advance to the "PTO Engine RPM Set Speed". Toggle the set switch again in order to increase the engine rpm to the "PTO Top Engine Limit". Toggling the resume switch decreases the engine rpm to the previous set speed.
Table 3
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO Engine RPM Set Speed Input A"
If the "PTO Engine RPM Set Speed A" parameter is programmed to the corresponding switch input option, the switch is used in order to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", "Remote Switches", or "Remote Throttle" and the "PTO Engine RPM Set Speed A" parameter must be programmed to a valid speed.
Table 4
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO Engine RPM Set Speed Input B"
If the "PTO Engine RPM Set Speed B" parameter is programmed to the corresponding switch input option, the switch is used in order to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", "Remote Switches", or "Remote Throttle" and the "PTO Engine RPM Set Speed B" parameter must be programmed to a valid speed.
Table 5
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO to Set Speed"
This parameter causes the ECM to proceed to the programmed "PTO Engine RPM Set Speed" when the PTO on/off switch is on. "PTO Configuration" must be programmed to "Cab Switches" or "Remote Switches" before this parameter can be programmed.Note: This parameter is not available when "PTO Configuration" is programmed to "Remote Throttle".
Table 6
Alternative     Default    
"YES"     "NO"    "PTO Cab Throttle RPM Limit"
This determines the engine rpm limit of the pedal position sensor for the cab accelerator and cab set/resume switch when "PTO Configuration" is programmed to "Cab Switches" and the PTO on/off circuit is ON. This parameter is intended to prevent engine overspeed when the dedicated PTO is used.
If the parameter is programmed to "Low Idle", the Cab Controls are ignored.
If the parameter is programmed to "Top Engine Limit" (TEL), the engine will operate to the programmed "Top Engine Limit".
If the parameter is programmed to "PTO Top Engine Limit", the engine will operate to the programmed "PTO Top Engine Limit".Note: "PTO Configuration" must be programmed to "Cab Switches" for this parameter to take effect. If "PTO Configuration" is programmed to "Remote Switches" or "Remote Throttle", the ECM will always ignore the cab controls when the PTO on/off circuit is on.
Table 7
Alternative     Default    
Low Idle, TEL and PTO TEL     TEL    


Parts six Volvo Penta:

969405
Six point socket scr
969405 Six point socket scr
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, D13B-A MP; D
969408
 
969408 Six point socket scr
1372, 2001; 2001B; 2001AG, 4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-225-R, 4.3GXiE-M, 4.3GXiE-P; 4.3GXiE-Q, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-270-R; 5.0GiCE-225-S, 5.0GXiCE-J; 5.0GXiCE
969407
 
969407 Six point socket scr
1372, 2001; 2001B; 2001AG, 4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-225-R, 4.3GXiE-M, 4.3GXiE-P; 4.3GXiE-Q, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-270-R; 5.0GiCE-225-S, 5.0GXiCE-J; 5.0GXiCE
969439
 
969439 Six point socket scr
D1-13; D1-13B; D1-20, D11B3-A MP; D11B4-A MP, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, D3-110I-A; D3-110I-B; D3-110I-C, D5A-T; D5A-TA; D5A-B TA, HS25A; HS25A-B; HS25A-C, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B;
20460068
 
20460068 Six point socket scr
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TD420VE; TAD420VE; TAD620VE, TD520VE; TD720VE
20460067
 
20460067 Six point socket scr
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA
888760
 
888760 Six point screw
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TD420VE; TAD420VE; TAD620VE, TD520GE; TAD530GE; TAD531GE, TD520VE; TD720VE
20460082
 
20460082 Six point socket scr, locking screw
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TD520GE; TAD530GE; TAD531GE
Back to top