7745600_124 Volvo.Penta Level sensor


7745600_124 Level sensor Volvo.Penta TAMD162A; TAMD162B; TAMD162C Level
7745600_124 Level sensor Volvo Penta
Rating:
68

Buy Level sensor 7745600_124 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 35
 

Compatible models:

Information:


Illustration 1 g01372933
(1) Clamp
Ensure that the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
Align the brackets in position to the fuel lines when the fasteners are tightened. This will ensure that no strain will be added to the fuel lines when the fasteners are tightened.Note: Fuel injector nozzle must be supported with a wrench. (2) Clamp location dimensions are in reference to vertical line (2). Vertical line (2) is through the center of the number one fuel pump outlet. (A) ... 365 6 mm (14.4 0.2 inch) (B) ... 195 6 mm (7.7 0.2 inch) (C) ... 165 6 mm (6.5 0.2 inch) (3) Clamp location dimensions are in reference to horizontal line (3). Horizontal line (3) is through the center of the pump outlets. (D) ... 84 6 mm (3.3 0.2 inch) (E) ... 97 6 mm (3.8 0.2 inch) (F) ... 110 6 mm (4.3 0.2 inch) (4) Fuel line nut Tighten the nuts that hold the fuel lines to the following torque. Use a 5P-0144 Fuel Line Socket. ... 40 7 N m (30 5 lb ft) (5) Clamp location dimensions are in reference to vertical line (5). Vertical line (5) is through the center of the fifth pump outlet. (G) ... 125 6 mm (4.9 0.2 inch) (H) ... 221 6 mm (8.7 0.2 inch)Type 2
Illustration 2 g01335747
(9) Clamp
Ensure that the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
Align the brackets in position to the fuel lines when the fasteners are tightened. This will ensure that no strain will be added to the fuel lines when the fasteners are tightened.Note: Fuel injector nozzle must be supported with a wrench. (6) Fuel line nut Tighten the nuts that hold the fuel lines to the following torque. Use a 5P-0144 Fuel Line Socket. ... 40 7 N m (30 5 lb ft) (7) Clamp location dimensions are in reference to vertical line (7). Vertical line (7) is through the center of the number one fuel pump outlet. (J) ... 478 6 mm (18.8 0.2 inch) (K) ... 386 5 mm (0.2 0.2 inch) (L) ... 233 6 mm (9.2 0.2 inch) (M) ... 155 8 mm (6.1 0.3 inch) (P) ... 123 4 mm (4.8 0.2 inch) (R) ... 157 4 mm (4.8 0.2 inch) (S) ... 191 5 mm (7.6 0.2 inch) (T) ... 228 7 mm (9.0 0.3 inch) (V) ... 325 4 mm (12.0 0.2 inch) (8) Clamp location dimensions are in reference to horizontal line (8). Horizontal line (8) is through the center of the fuel pump. (N) ... 148 4 mm (5.8 0.2 inch) (10) Clamp location dimensions are in reference to vertical line (10). Vertical line (10) is through the center of the number five pump outlet. (U) ... 113 6 mm (4.5 0.2 inch) (W) ... 337 13 mm (13.3 0.5 inch)Type 3
Illustration 3 g01335748
Top view
Ensure that the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
Align the brackets in position to the fuel lines when the fasteners are tightened. This will ensure that no strain will be added to the fuel lines when the fasteners are tightened.Note: Fuel injector nozzle must be supported with a wrench. (11) Clamp location dimensions are in reference to vertical line (11). Vertical line (11) is through the center of the number one fuel outlet. (X) ... 85 3 mm (3.3 0.1 inch) (Y) ... 100 3 mm (3.9 0.1 inch) (Z) ... 115 3 mm (4.5 0.1) (AA) ... 100 3 mm (3.9 0.1 inch) (AB) ... 115 3 mm (4.5 0.1 inch) (AC) ... 140 3 mm (5.5 0.1 inch) (12) Clamp location dimensions are in reference to horizontal line (12). Horizontal line (12) is through the center of the fuel pump. (AD) ... 155 3 mm (6.1 0.1 inch) (AE) ... 217 3 mm (8.5 0.1 inch) (AF) ... 361 3 mm (14.2 0.1 inch)
Illustration 4 g01368799
Right side view
Ensure that the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
Align the brackets in position to the fuel lines when the fasteners are tightened. This will ensure that no strain will be added to the fuel lines when the fasteners are tightened.Note: Fuel injector nozzle must be supported with a wrench. (13) Cla


Parts level Volvo Penta:

863943
 
863943 Level gauge
D70CHC; D70CRC; TD70CHC, MD31A; TMD31A; TMD31B, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B
872315
 
872315 Level guard
TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TMD100C, TMD102A; TAMD102A; TAMD102D
863777
 
863777 Level guard
D70CHC; D70CRC; TD70CHC, TAMD162A; TAMD162B; TAMD162C, TD100CHC; TD100CRC; TD121CHC
Back to top