242324 Volvo.Penta Spring


242324 Spring Volvo.Penta MD6; MD6A; MD6B Spring
242324 Spring Volvo Penta
Rating:
23

Buy Spring 242324 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$128.99

19-12-2024
34.0[15.30] pounds
Amazon.com
Kelly Edge Touring A/S All-Season 215/65R17 SL 99 V Tire
Kelly All Season traction: Biting tread block edges designed to provide all-season traction in wet, dry and snowy conditions || Wet traction: Sweeping grooves help evacuate water and slush from the tread for enhanced grip || Long treadwear: Sturdy angled tread blocks help stabilize the tread footprint to promote long treadwear || Smooth ride: Symmetrical tread pattern: Confident handling and smooth ride
$43.33
 

02-06-2024
0.44[0.20] Pounds
IT: BRIXIAMOTO
Roller drive POLINI 19X12 G 5,5 (242324)
POLINI Product code: MS-U242.324
Number on catalog scheme: 47
 

Compatible models:

MD6; MD6A; MD6B   Volvo.Penta

Volvo Penta entire parts catalog list:

MD6; MD6A; MD6B; MD7; MD7A; MD7B

Information:


Table 1
J1939 Code and Description Comments
114-5
Net Battery Current : Current Below Normal The alternator is charging the starting batteries, but not charging the trailer batteries.
A wire is bad on the alternator side or a failed Isolation (ISO) relay.
The circuit is not hooked up correctly if the wiring is good.
677-5
Engine Starter Motor Relay : Current Below Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the starter motor relay.
677-6
Engine Starter Motor Relay : Current Above Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the starter motor relay.
1267-5
Idle Shutdown Vehicle Accessories Relay Driver Circuit : Current Below Normal This code indicates that the EIRS battery ISO relay current is below normal.
1267-6
Idle Shutdown Vehicle Accessories Relay Driver Circuit : Current Above Normal This code indicates that the EIRS battery ISO relay current is above normal.
4210-5
Engine Pre-lube Drive : Current Below Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the engine pre-lube pump.
4210-6
Engine Pre-lube Drive : Current Above Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the engine pre-lube pump.
5085-5
Engine Idle Management Active Lamp Command : Current Below Normal This code indicates that the EIRS active lamp current is below normal.
5085-6
Engine Idle Management Active Lamp Command : Current Above Normal This code indicates that the EIRS active lamp current is above normal.
7498-5
SLI Battery #2 Net Current : Current Below Normal The alternator is charging trailer batteries, but not charging the starter batteries.
The wire or ISO relay is bad going to the starting batteries.
7498-6
SLI Battery #2 Net Current : Current Above Normal The ISO relay has failed and is stuck closed
7748-5
Engine Starter 1 Feedback : Current Below Normal This code indicates that there is a problem with the starter relay and/or the electrical circuit on the Electronic Control Module (ECM).
7748-6
Engine Starter 1 Feedback : Current Above Normal This code indicates that there is a problem with the starter relay and/or the electrical circuit on the ECM.
7749-5
Engine Starter 2 Feedback : Current Below Normal This code indicates that there is a problem with the starter relay and/or the electrical circuit on the ECM.
7749-6
Engine Starter 2 Feedback : Current Above Normal This code indicates that there is a problem with the starter relay and/or the electrical circuit on the ECM.
9372-5
Engine Idle Management Pending Event Lamp Command : Current Below Normal This code indicates that the event beacon lamp current is below normal.
9372-6
Engine Idle Management Pending Event Lamp Command : Current Above Normal This code indicates that the event beacon lamp current is above normal.
9373-5
Automatic Start Request Inhibit Indicator : Current Below Normal This code indicates that the EIRS secondary start inhibit lamp current is below normal.
9373-6
Automatic Start Request Inhibit Indicator : Current Above Normal This code indicates that the EIRS secondary start inhibit lamp current is above normal. The applicable Electronic Control Module (ECM) monitors the current flow through the coils of the applicable components.The applicable ECM sets a diagnostic trouble code if the current flow through a coil is incorrect. These codes can be activated only when the applicable ECM is sending a command to the control valves. A -5 code indicates that the current flow through the circuit is low and there is an open in the circuit. A -6 code indicates that the current flow through the circuit is high and there is a short in the circuit.Electrical Checkouts on the Cat® Electronic Technician (ET)
Table 2
Component Electrical Checkout
Engine Starter Motor Relay Engine Starter Motor Relay Override
Prelubrication System Relay Prelubrication Relay Override
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Disconnect the solenoid from the harness.
C. Connect a jumper wire between the terminals of the harness connector for the affected coil. The coil is replaced with a short circuit.
Create a Short
Result: A -5 code became active during the electrical checkout. The ECM did not detect the jumper wire. There is an open circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -6 code is activated during the electrical checkout. The ECM detected the jumper wire. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Disconnect the solenoid from the harness.
Create an Open
Result: A -6 code became active during the electrical checkout. The ECM did not detect the open circuit. There is a short circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -5 code is activated during the electrical checkout. The ECM detected the open circuit. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts spring Volvo Penta:

941907
Spring washer
941907 Spring washer
120S-A; 120S-B; 120S-D, 130S-C; 130SR-C, 130S; 130S-B; 130SR-A, 150S-C; 150SR-C, 150S; 150S-B; 150SR, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 3.0GXiC-J; 3.0GXi-J, 430; 430A; 430B, 5.0GXiC-270-R; 5.0GiC-225-S, 5.0GXiC-J; 5.0GXiC-JF; 5.0GiC-J, 5.0
942336
 
942336 Spring washer
230A; 230B; 250A, 251A, 4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 430; 430A; 430B, 5.0GXi-A; 5.7Gi-A; 5.7GXi-A, 5.0GXi-B; 5.0GXi-BF; 5.0OSi-B, 5.7Gi-C; 5.7Gi-CF
949607
 
949607 Spring washer
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31L-A; AD31P-A; AD41L-A, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200D; AQ200F; 280B,
951953
 
951953 Spring pin
AQ115A; AQ115B; AQ130, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B, TAD1240GE; TAD1241GE; TAD1242GE, TAD940VE; TAD941VE; TAD942VE, TD71A; TID71A; TWD710V, TWD1240VE; TAD1241VE; TAD1242VE
829548
 
829548 Spring
MD5A; MD5B; MD5C, MD6; MD6A; MD6B
951957
Spring pin
951957 Spring pin
D42A; D42A PP, IPS15-A, IPS15-B, IPS2-A, IPS2-B, IPS2-C, IPS20-D, IPS3-A, IPS3-C, IPS30-D, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
840035
 
840035 Spring pin
MD6; MD6A; MD6B
243564
 
243564 Spring
MD6; MD6A; MD6B
Back to top