3834466 Volvo.Penta Starter element


3834466 Starter element Volvo.Penta D13B-F MG; D13B-E MG; D13B-E MG (FE), TAD1240GE; TAD1241GE; TAD1242GE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1360VE, TAD1361VE, TAD1363VE, TAD1640GE; TAD1641GE; TAD1642GE, TAD1641VE; TAD1642VE; TAD1643VE, TWD Starter
3834466 Starter element Volvo Penta
Rating:
58

Buy Starter element 3834466 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Volvo Penta entire parts catalog list:

D13B-F MG; D13B-E MG; D13B-E MG (FE); D13B-F MG (FE)
TAD1240GE; TAD1241GE; TAD1242GE
TAD1340VE; TAD1341VE; TAD1342VE; TAD1343VE; TAD1344VE; TAD1345VE; TAD1360VE; TAD1361VE; TAD1362VE; TAD1363VE; TAD1364VE; TAD1365VE; TAD1360-
TAD1341GE; TAD1342GE; TAD1343GE; TAD1344GE; TAD1345GE; TAD1350GE; TAD1351GE; TAD1352GE; TAD1353GE; TAD1354GE; TAD1355GE
TAD1350VE
TAD1360VE
TAD1361VE
TAD1363VE
TAD1640GE; TAD1641GE; TAD1642GE; TAD1650GE; TAD1651GE; TWD1643GE; TWD1652GE; TWD1653GE; TWD1663GE
TAD1641VE; TAD1642VE; TAD1643VE; TAD1650VE; TAD1660VE; TAD1661VE; TAD1662VE; TAD1640VE-B; TAD1641VE-B; TAD1642VE-B; TAD1660-62VE; TAD1662VE
TWD1240VE; TAD1241VE; TAD1242VE; TAD1250VE; TAD1251VE; TAD1252VE

Information:


The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Illustration 1 g01131211
Leaky seal at the connector (typical example)
Illustration 2 g01131276
Diagram for the installation of a connector plug (typical example)
(1) Electronic Control Module (ECM) connector
(2) Correctly inserted plug
(3) Incorrectly inserted plug
Illustration 3 g01131019
Seal for a three-pin connector (typical example)
Illustration 4 g01131165
Seal for ECM connector (typical example)
Table 1
Troubleshooting Test Steps Values Results
1. Check Connectors for Moisture and Corrosion
A. Inspect all wiring harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. Refer to Illustration 1. This will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
B. Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector. Refer to Illustration 2.
C. Disconnect the suspect connector and inspect the connector seal. Ensure that the seals are in good condition. If necessary, replace the connector.
D. Thoroughly inspect the connectors for evidence of moisture entry.
Note: It is normal to see some minor seal abrasion on connector seals. Minor seal abrasion will not allow the entry of moisture.
If moisture or corrosion is evident in the connector, the source of the moisture entry must be found and the source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the problem will recur. Simply drying the connector will not fix the problem. Check the following items for the possible moisture entry path:
• Missing seals
• Improperly installed seals
• Nicks in exposed insulation
• Improperly mated connectors
Moisture can also travel to a connector through the inside of a wire. If moisture is found in a connector, thoroughly check the connector's harness for damage. Also check other connectors that share the harness for moisture.
Note: The ECM is a sealed unit. If moisture is found in an ECM connector, the ECM is not the source of the moisture. Do not replace the ECM.
Connectors
Result: The harness wiring, connectors, and seals are in good condition.
Proceed to Test Step 2.
Result: A problem has been found with the harness or the connectors.
Repair: Repair the connectors or the wiring, as required. Ensure that all of the seals are properly in place. Ensure that the connectors have been reattached.
If corrosion is evident on the pins, sockets or the connector, use only denatured alcohol to remove the corrosion. Use a cotton swab or a soft brush to remove the corrosion.
If moisture was found in the connectors, run the engine for several minutes and check again for moisture. If moisture reappears, the moisture is wicking into the connector. Even if the moisture entry path is repaired, it may be necessary to replace the wires.
Verify that the repair eliminates the problem.
STOP
2. Check the Wires for Damage to the Insulation
A. Carefully inspect each wire for signs of abrasion, of nicks, and of cuts.
Inspect the wires for the following conditions:
• Exposed insulation
• Rubbing of a wire against the engine
• Rubbing of a wire against a sharp point
B. Check all of the wiring harness fasteners in order to verify that the harness is properly secured. Also check all of the fasteners in order to verify that the harness is not compressed. Pull back the harness sleeves in order to check for a flattened portion of wire. A fastener that has been overtightened flattens the harness. This damages the wires that are inside the harness.
Wiring
Result: The harness is OK.
Proceed to Test Step 3.
Result: There is damage to the harness.
Repair: Repair the wires or replace the wires, as required. Verify that the repair eliminates the problem.
STOP
3. Inspect the Connector Terminals
A. Visually inspect each terminal in the connector. Verify that the terminals are not damaged. Verify that the terminals are properly aligned in the connector and verify that the terminals are properly located in the connector.
Connector Terminals
Result: The terminals are OK.
Proceed to Test Step 4.
Result: The terminals of the connector are damaged.
Repair: Repair the terminals and/or replace the terminals, as required.
STOP
Illustration 5 g01131435
Receptacle lock wedge (typical example)


Parts starter Volvo Penta:

874468
Starter motor
874468 Starter motor
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
3803872
Starter motor, exch
3803872 Starter motor, exch
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
21103722
Starter motor
21103722 Starter motor
1372, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, TAD1351VE; TAD1352VE; TAD1353VE, TAD1352VE,
3801289
Starter motor, exch
3801289 Starter motor, exch
1372, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE;
3830007
 
3830007 Starter pinion
D12D-A MG; D12D-E MG, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P
3827444
Starter motor
3827444 Starter motor
TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
3803571
 
3803571 Starter motor
TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
21103718
Starter motor
21103718 Starter motor
TAD1240GE; TAD1241GE; TAD1242GE, TWD1240VE; TAD1241VE; TAD1242VE
Back to top