3036013 Volvo.Penta Stay


3036013 Stay Volvo.Penta DH10A; DH10A 285; DH10A 360 Stay
3036013 Stay Volvo Penta
Rating:
23

Buy Stay 3036013 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$114.30
 

05-10-2022

-: -
OEM Phoenix Contact 3036013, (1 Items)
$17.37
 

05-10-2022
0.0006[0.00] Pounds
-: -
Phoenix Contact 3036013 Conn; Term Blk; 2; 4; 26-14 AWG; Green-Yellow; PA; 6 kV; Spring-Cage
Number on catalog scheme: 47
 

Compatible models:

Volvo Penta entire parts catalog list:

DH10A; DH10A 285; DH10A 360; DH10A Rail; THD102KD; THD102KB

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
107-3
Engine Air Filter 1 Differential Pressure : Voltage Above Normal 582-3
Air Filter Differential Pressure Switch : Voltage Above Normal This code indicates a fault in the circuit for the air filter restriction switch. The Electronic Control Module (ECM) detects the following conditions:
The air filter restriction switch circuit is open for at least 1 second.
The engine is not running.
Monitoring of air filter restriction when the engine is running will be disabled whilst this code is active.
107-4
Engine Air Filter 1 Differential Pressure : Voltage Below Normal 582-4
Air Filter Differential Pressure Switch : Voltage Below Normal This code indicates a fault in the circuit for the air filter restriction switch. The Electronic Control Module (ECM) detects the following conditions:
The air filter restriction switch circuit is open for at least 1 second.
The engine is not running.
Monitoring of air filter restriction when the engine is running will be disabled whilst this code is active. The engine is equipped with an air filter restriction switch. The type of switch that is installed can be a "Normally Open" switch or a "Normally Closed" switch.Use the electronic service tool to check the configuration parameters to check the type of air filter restriction switch that is installed.Table 2 and Table3 contain the normal engine conditions and switch states for the air filter restrictions switch.
Table 2
Diagnostic Summary for a "Normally Open" Air Filter Restriction Switch
Engine Condition Switch State Active Diagnostic Code
Not running (key on) Open Normal condition
Running Open Normal Condition (no air filter restriction detected)
Not running (key on) Closed 107-4 (582-4)
Running Closed 107-15 (E583-1) or 107-16 (E583-2) (air filter restriction detected)
Table 3
Diagnostic Summary for a "Normally Closed" Air Filter Restriction Switch
Engine Condition Switch State Active Diagnostic Code
Not running (key on) Closed Normal condition
Running Closed Normal Condition (no air filter restriction detected)
Not running (key on) Open 107-3 (582-3)
Running Open 107-15 (E583-1) or 107-16 (E583-2) (air filter restriction detected) Refer to the Electrical Schematic for the application if needed.
Table 4
Troubleshooting Test Steps Values Results
1. Check the "Air Filter Restriction Switch Configuration"
A. Turn the keyswitch to ON.
B. Connect the electronic service tool to the diagnostic connector.
C. Under "Configuration Parameters", check the "Air Filter Restriction Switch Configuration".
Note: If the type of switch cannot be identified using the electronic service tool, contact the Dealer Solutions Network (DSN) for the information.
Air Filter Restriction Switch Configuration
Results : The switch is configured to "Normally Open".
Proceed to Test Step 2.
Results : The switch is configured to "Normally Closed".
Proceed to Test Step 3.
2. Check the Air Filter Restriction Switch
A. Turn the keyswitch to OFF.
B. Disconnect the air filter restriction switch from the wiring harness connector.
C. Turn the keyswitch to ON.
D. Monitor the electronic service tool for active codes.
Codes
Results : There is not an active 107-4 or 582-4 code. A failed air filter restriction switch has been detected.
Repair : Replace the air filter restriction switch.
Verify that the repairs eliminated the issue. Return the machine to service.
Results : There is an active 107-4 or 582-4 code. A short circuit in the wiring harness has been detected.
Repair : Repair or replace the wiring harness.
Verify that the repair has eliminated the issue.
If the fault is still present, contact the Dealer Solutions Network (DSN).
3. Check the Air Filter Restriction Switch
A. Turn the keyswitch to OFF.
B. Disconnect the air filter restriction switch from the wiring harness connector.
C. Install a jumper wire in the wiring harness connector between the signal and ground terminals.
D. Turn the keyswitch to ON.
E. Monitor the electronic service tool for active fault codes.
Codes
Results : There is not an active 107-3 or 582-3 diagnostic code. A failed air filter restriction switch has been detected.
Repair : Replace the air filter restriction switch.
Verify that the repairs eliminated the issue. Return the machine to service.
Results : There is an active 107-3 or 582-3 diagnostic code. An open circuit in the wiring harness has been detected.
Repair : Repair or replace the wiring harness.
Verify that the repair has eliminated the issue.
If the fault is still present, contact the Dealer Solutions Network (DSN).
If this procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solution Network (DSN).


Parts stay Volvo Penta:

9957607
 
9957607 Stay
DH10A; DH10A 285; DH10A 360
3037383
 
3037383 Stay
DH10A; DH10A 285; DH10A 360
Back to top