3884546 Volvo.Penta Stud


3884546 Stud Volvo.Penta D1-13; D1-13B; D1-20 Stud
3884546 Stud Volvo Penta
Rating:
83

Buy Stud 3884546 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 9
 

Compatible models:

D1-13; D1-13B; D1-20   Volvo.Penta

Volvo Penta entire parts catalog list:

D1-13; D1-13B; D1-20; D1-20B; D1-30; D1-30B; D2-40; D2-40B; D1-13F; D1-20F; D1-30F; D2-40F

Information:


Never service the air cleaner element with the engine running since this will allow dirt to enter the engine.
Servicing the Air Cleaner Elements
Note: The air filter system may not have been provided by Catapillar. The procedure that follows is for a typical air filter system. Refer to the OEM information for the correct procedure.If the air cleaner element becomes plugged, the air can split the material of the air cleaner element. Unfiltered air will drastically accelerate internal engine wear. Refer to the OEM information for the correct air cleaner elements for your application.
Check the precleaner (if equipped) and the dust bowl daily for accumulation of dirt and debris. Remove any dirt and debris, as needed.
Operating in dirty conditions may require more frequent service of the air cleaner element.
The air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.Replace the dirty air cleaner elements with clean air cleaner elements. Before installation, the air cleaner elements should be thoroughly checked for tears and/or holes in the filter material. Inspect the gasket or the seal of the air cleaner element for damage. Maintain a supply of suitable air cleaner elements for replacement purposes.Dual Element Air Cleaners
The dual element air cleaner contains a primary air cleaner element and a secondary air cleaner element. The primary air cleaner element can be used up to six times if the element is properly cleaned and properly inspected. The primary air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.The secondary air cleaner element is not serviceable. Refer to the OEM information for instructions in order to replace the secondary air cleaner element. When the engine is operating in environments that are dusty or dirty, air cleaner elements may require more frequent replacement.
Illustration 1 g00736431
(1) Cover
(2) Primary air cleaner element
(3) Secondary air cleaner element
(4) Air inlet
Remove the cover. Remove the primary air cleaner element.
The secondary air cleaner element should be removed and discarded for every three cleanings of the primary air cleaner element. Note: Refer to "Cleaning the Primary Air Cleaner Elements".
Cover the air inlet with tape in order to keep dirt out.
Clean the inside of the air cleaner cover and body with a clean, dry cloth.
Remove the tape for the air inlet. Install the secondary air cleaner element. Install a primary air cleaner element that is new or cleaned.
Install the air cleaner cover.
Reset the air cleaner service indicator. Cleaning the Primary Air Cleaner Elements
Caterpillar recommends certified air filter cleaning services that are available at Caterpillar dealers. The Caterpillar cleaning process uses proven procedures to assure consistent quality and sufficient filter life.Observe the following guidelines if you attempt to clean the filter element:Do not tap or strike the filter element in order to remove dust.Do not wash the filter element.Use low pressure compressed air in order to remove the dust from the filter element. Air pressure must not exceed 207 kPa (30 psi). Direct the air flow up the pleats and down the pleats from the inside of the filter element. Take extreme care in order to avoid damage to the pleats.Do not use air filters with damaged pleats, gaskets, or seals. Dirt entering the engine will cause damage to engine components.
The primary air cleaner element can be used up to six times if the element is properly cleaned and properly inspected. When the primary air cleaner element is cleaned, check for rips or tears in the filter material. The primary air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.Use clean primary air cleaner elements while dirty elements are being cleaned.
Do not clean the air cleaner elements by bumping or tapping. This could damage the seals. Do not use elements with damaged pleats, gaskets or seals. Damaged elements will allow dirt to pass through. Engine damage could result.
Visually inspect the primary air cleaner elements before cleaning. Inspect the air cleaner elements for damage to the seal, the gaskets, and the outer cover. Discard any damaged air cleaner elements.There are two common methods that are used to clean primary air cleaner elements:
Pressurized air
Vacuum cleaningPressurized Air
Personal injury can result from air pressure.Personal injury can result without following proper procedure. When using pressure air, wear a protective face shield and protective clothing.Maximum air pressure at the nozzle must be less than 205 kPa (30 psi) for cleaning purposes.
Pressurized air can be used to clean primary air cleaner elements that have not been cleaned more than three times. Use filtered, dry air with a maximum pressure of 207 kPa (30 psi). Pressurized air will not remove deposits of carbon and oil.
Illustration 2 g00281692Note: When the primary air cleaner elements are cleaned, always begin with the clean side (inside) in order to force dirt particles toward the dirty side (outside).Aim the air hose so that air flows along the length of the filter. Follow the direction of the paper pleats in order to prevent damage to the pleats. Do not aim the air directly at the face of the paper pleats.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Vacuum Cleaning
Vacuum cleaning is a good method for removing accumulated dirt from the dirty side (outside) of a primary air cleaner element. Vacuum cleaning is especially useful for cleaning primary air cleaner elements which require daily cleaning because of a dry, dusty environment.Cleaning from the clean side (inside) with pressurized air is recommended prior to vacuum cleaning the dirty side (outside) of a primary air cleaner element.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Inspecting the Primary Air Cleaner Eleme


Parts stud Volvo Penta:

953047
 
953047 Stud
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D3-110I-A; D3-110I-B; D3-110I-C, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TD120HPP; TID120HPP, TID12
3812420
 
3812420 Stud
D1-13; D1-13B; D1-20
3583708
 
3583708 Stud
D1-13; D1-13B; D1-20, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B
3884526
 
3884526 Stud
D1-13; D1-13B; D1-20
3584203
 
3584203 Stud
D1-13; D1-13B; D1-20, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C
881609
 
881609 Stud
1372, 4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-225-R, 4.3GXiE-M, 4.3GXiE-P; 4.3GXiE-Q, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-270-R; 5.0GiCE-225-S, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0G
830928
Stud
830928 Stud
4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-M, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7Gi-300-J; 5.7Gi-300-JF; 5.7OSi-300-J, 5.
953000
 
953000 Stud
D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, TAD1340VE; TAD1341VE; TAD1342VE, TAD1350VE, TAD1351VE; TAD1352VE; TAD1353VE, TAD1371VE; TAD1372VE; TAD1373VE,
Back to top