Table 1
Diagnostic Codes Table    
Code    Conditions which Generate this Code    System Response    
1-5 Cylinder #1 Injector : Current Above Normal     The engine Electronic Control Module (ECM) detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
1-6 Cylinder #1 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
2-5 Cylinder #2 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
2-6 Cylinder #2 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
3-5 Cylinder #3 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
3-6 Cylinder #3 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
4-5 Cylinder #4 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
4-6 Cylinder #4 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
5-5 Cylinder #5 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
5-6 Cylinder #5 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
6-5 Cylinder #6 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
6-6 Cylinder #6 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
7-5 Cylinder #7 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
7-6 Cylinder #7 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
8-5 Cylinder #8 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
8-6 Cylinder #8 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
9-5 Cylinder #9 Injector : Current Above Normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
9-6 Cylinder #9 Injector : Current Above Normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
10-5 Cylinder #10 Injector : Current