420427 Tensioner Volvo.Penta
AQD70D; TAMD70D; TAMD70E, TD70G; TD70G-83; TD70GPP
Tensioner

Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$50.00
02-12-2023
CN: Waiding
New Tank Coolant Level Sensor Switch 42-2347 422347 42427 42-427 42-0427 Compatible with Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M
CERYNiTIS Part Number: 422347 || Application: For Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M
CERYNiTIS Part Number: 422347 || Application: For Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M
$43.00
02-12-2023
CN: Xiehaparts
Haiyazhma New Coolant Level Switch 42-2347 422347 42-0427 420427 42-427 42427 Compatible with Thermo King T-1080R T-880S T-1200R T-880R T-1000R T-800R T-680R T-600R T-1080S T-580 T-890 T-1090 T-680S
Haiyazhma Part Name: Coolant Level Switch || Part Numbers: 42-2347 422347 42-0427 420427 || Compatible with Thermo King T-1080R T-880S T-1200R T-880R T-1000R T-800R T-680R T-600R T-1080S T-580 T-890 T-1090 T-680S || 1.Please confirm according to the correct part number and not just the model number. || 2.Please leave us physical address (home or office address) but not P.O box address.
Haiyazhma Part Name: Coolant Level Switch || Part Numbers: 42-2347 422347 42-0427 420427 || Compatible with Thermo King T-1080R T-880S T-1200R T-880R T-1000R T-800R T-680R T-600R T-1080S T-580 T-890 T-1090 T-680S || 1.Please confirm according to the correct part number and not just the model number. || 2.Please leave us physical address (home or office address) but not P.O box address.
Haiyazhma New Tank Coolant Level Sensor Switch 42-2347 422347 42427 42-427 42-0427 Compatible with Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M
Haiyazhma Part Name: Tank Coolant Level Sensor Switch || Part Numbers: 42-2347 422347 42427 42-427 42-0427 || Compatible with Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M || 1.Please confirm according to the correct part number and not just the model number. || 2.Please leave us physical address (home or office address) but not P.O box address.
Haiyazhma Part Name: Tank Coolant Level Sensor Switch || Part Numbers: 42-2347 422347 42427 42-427 42-0427 || Compatible with Thermo King T-series T-1000 T-1080R T-1000M T-1000R T-1080R T-1080S T-1200R T-500R T-800R T-800M || 1.Please confirm according to the correct part number and not just the model number. || 2.Please leave us physical address (home or office address) but not P.O box address.
Compatible models:
AQD70D; TAMD70D; TAMD70E
TD70G; TD70G-83; TD70GPP
Volvo.Penta
Volvo Penta entire parts catalog list:
TD70G; TD70G-83; TD70GPP; TD70GPP-83; TID70G; TID70GPP; TID70GG; TD70GG; TD70GG-83
Information:
Status Groups for Cat ET
The reference to the Cat ET imply a reference to the Caterpillar Communication Tool Kit when features are common between the two.Status Group 1 - Link Status
Illustration 1 g01266358
This section provides information about the "Cat Datalink Module Identifier Configuration". The PL1000T can be manually configured to occupy three distinct source addresses on the Cat Datalink .This status parameter indicates which of the three source addresses is currently configured.When multiple PL1000Ts are connected to the same Cat Datalink network, they must each be configured with a unique source address.Cat Datalink "Boost" status indicates if the "CDL Boost" feature is enabled or disabled. When enabled, the Cat Datalink may be extended up to 300 m (1000 ft).Status Group 2 - J1939 Bridge Function Enable Status
Illustration 2 g01132172
When this function is enabled, the PL1000T will relay all J1939 data messages from its CAN port 1 to CAN port 2 and from CAN port 2 to CAN port 1.Status Group 3 - Customer Communication Module (CCM) Status
Illustration 3 g01266359
The "CCM Status" parameter is used to confirm the settings of the CCM Feature:
serial port selection
baud rate
stop bits
data bits
parity
protocol detection
password protection
baud rate change enable
protocol configured
type
current level accessThe host device communicating with the PL1000T using the CCM feature must match the settings seen on this screen.Status Group 4 - Engine Vision Interface Module (EVIM) Status
Illustration 4 g01266361
The "Engine Vision Interface Module" (EVIM) status parameter is used to confirm the port selection, baud rate, data size, and parity of the (EVIM) configuration.The "Engine Vision Display" must be configured to match the status information on this screen to allow proper communications between it and the PL1000T.Status Group 5 - Global Position System Information Module (GPSIM) Status
Illustration 5 g01266375
The "Global Position System Information Module" (GPSIM) status parameter is used to confirm the port selection, baud rate, data size, and parity of the GPSIM configuration. The GPS sensing module that is connected to this port must match the status information in this screen to allow proper communications between it and the PL1000T.The GPSIM screen also displays the "Vessel Speed" (knots), "Ground Speed" (MPH), "Directional Heading" (degrees), "Latitude" (degrees), and "Longitude" (degrees). The information can be viewed in order to confirm the communications between the GPS sensing module and the PL1000T.Status Group 6 - CCM Statistics
Illustration 6 g01266380
The "CCM Statistics" status screen is used to observe the number of messages that are being transmitted and that are being received, whether valid or invalid, by the PL1000T.A consistent increase in the number of invalid messages that are received, indicates there are communication problems between the PL1000T and the "Engine Vision Display". The port selection, baud rate, parity, and data size configurations for each of the modules should be checked. The configurations for each selection must match in order to enabled communications.Status Group 7 - EVIM Statistics
Illustration 7 g01266391
The "EVIM Statistics" status screen is used to observe the rate of messages that are being received by the PL1000T.A consistent increase in the number of invalid messages that are received, indicates there are communication problems between the PL1000T and the "Engine Vision Display". The port selection, baud rate, parity, and data size configurations for each of the modules should be checked. The configurations for each selection must match in order to enabled communications.Status Group 8 - GPSIM Statistics
The reference to the Cat ET imply a reference to the Caterpillar Communication Tool Kit when features are common between the two.Status Group 1 - Link Status
Illustration 1 g01266358
This section provides information about the "Cat Datalink Module Identifier Configuration". The PL1000T can be manually configured to occupy three distinct source addresses on the Cat Datalink .This status parameter indicates which of the three source addresses is currently configured.When multiple PL1000Ts are connected to the same Cat Datalink network, they must each be configured with a unique source address.Cat Datalink "Boost" status indicates if the "CDL Boost" feature is enabled or disabled. When enabled, the Cat Datalink may be extended up to 300 m (1000 ft).Status Group 2 - J1939 Bridge Function Enable Status
Illustration 2 g01132172
When this function is enabled, the PL1000T will relay all J1939 data messages from its CAN port 1 to CAN port 2 and from CAN port 2 to CAN port 1.Status Group 3 - Customer Communication Module (CCM) Status
Illustration 3 g01266359
The "CCM Status" parameter is used to confirm the settings of the CCM Feature:
serial port selection
baud rate
stop bits
data bits
parity
protocol detection
password protection
baud rate change enable
protocol configured
type
current level accessThe host device communicating with the PL1000T using the CCM feature must match the settings seen on this screen.Status Group 4 - Engine Vision Interface Module (EVIM) Status
Illustration 4 g01266361
The "Engine Vision Interface Module" (EVIM) status parameter is used to confirm the port selection, baud rate, data size, and parity of the (EVIM) configuration.The "Engine Vision Display" must be configured to match the status information on this screen to allow proper communications between it and the PL1000T.Status Group 5 - Global Position System Information Module (GPSIM) Status
Illustration 5 g01266375
The "Global Position System Information Module" (GPSIM) status parameter is used to confirm the port selection, baud rate, data size, and parity of the GPSIM configuration. The GPS sensing module that is connected to this port must match the status information in this screen to allow proper communications between it and the PL1000T.The GPSIM screen also displays the "Vessel Speed" (knots), "Ground Speed" (MPH), "Directional Heading" (degrees), "Latitude" (degrees), and "Longitude" (degrees). The information can be viewed in order to confirm the communications between the GPS sensing module and the PL1000T.Status Group 6 - CCM Statistics
Illustration 6 g01266380
The "CCM Statistics" status screen is used to observe the number of messages that are being transmitted and that are being received, whether valid or invalid, by the PL1000T.A consistent increase in the number of invalid messages that are received, indicates there are communication problems between the PL1000T and the "Engine Vision Display". The port selection, baud rate, parity, and data size configurations for each of the modules should be checked. The configurations for each selection must match in order to enabled communications.Status Group 7 - EVIM Statistics
Illustration 7 g01266391
The "EVIM Statistics" status screen is used to observe the rate of messages that are being received by the PL1000T.A consistent increase in the number of invalid messages that are received, indicates there are communication problems between the PL1000T and the "Engine Vision Display". The port selection, baud rate, parity, and data size configurations for each of the modules should be checked. The configurations for each selection must match in order to enabled communications.Status Group 8 - GPSIM Statistics
Parts tensioner Volvo Penta:
838073
838073 Tensioner
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, MD5A; MD5B; MD5C, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TD120HP-86; TD121; TD121G, TD120HPP; TI
843819
966797
966797 Tensioner
TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87, TD60D; TD60D-83; TD60DPP-83, TD70G; TD70G-83; TD70GPP
466597