3842883 Volvo.Penta Terminal block


3842883 Terminal block Volvo.Penta D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D5A-T; D5A-TA; D5A-B TA, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2 Terminal
3842883 Terminal block Volvo Penta
Rating:
98

Buy Terminal block 3842883 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 11
 

Volvo Penta entire parts catalog list:

D12D-A MG; D12D-E MG
D12D-A MH; D12D-B MH; D12D-C MH; D12D-E MH; D12D-G MH; D12C-A MP; D12D-A MP; D12D-B MP; D12D-C MP; D12D-D MP; D12D-E MP; D12D-F MP; D12D-G M
D13B-E MH; D13B-E MH (FE); D13B-N MH; D13B-N MH (FE)
D13B-F MG; D13B-E MG; D13B-E MG (FE); D13B-F MG (FE)
D16C-A MG
D16C-A MH; D16C-B MH; D16C-C MH
D16C-D MH
D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA
D9A2A; D9A2A D9-425; D9A2A D9-500; D9A2A D9-500 (R4); D9A2A D9-575; D9A2B D9-425; D9A2B D9-500 (R5); D9A2B D9-575; D9A2C D9-425; D9A2D D9
D9A2A; D9A2A MG; D9A2A D9A-MG

Information:


Operating units above the rating definitions will result in shorter service life before overhaul.
Industrial Rating Definitions
A Rating (Continuous)
* For heavy-duty service when engine is operated at rated load and speed up to 100 percent of the time without interruption or load cycling.* Time at full load up to 100 percent of the duty cycle.* Typical examples are: pipeline pumping, ventilation, and customer specifications.B Rating
* For service where power and/or speed are cyclic.* Time at full load not to exceed 80 percent of the duty cycle.* Typical examples are: irrigation where normal pump demand is 85 percent of the duty cycle, oil field mechanical pumping and drilling, and stationary/plant air compressors.C Rating (Intermittent)
* For service where power and/or speed are cyclic.* The horsepower and speed capability of the engine can be used for one uninterrupted hour, followed by one hour of operation at or below the A rating.* Time at full load not to exceed 50 percent of the duty cycle.* Typical examples are: agricultural tractors, harvesters and combines, off-highway trucks, fire pump application power, blast hole drills, rock crushers and wood chippers with high torque rise, and oil field hoisting.D Rating
* For service when rated power is required for periodic overloads.* The maximum horsepower and speed capability of the engine can be used for a maximum of 30 uninterrupted minutes, followed by one hour of followed by one hour of C rating operation.* Time at full load not to exceed 10 percent of the duty cycle.* Typical examples are: offshore cranes, runway snow blowers, water well drills, portable air compressors, and fire pump certification power.E Rating
* For service where rated power is required for a short time for initial starting or sudden overload. For emergency service where standard power is unavailable.* The maximum horsepower and speed capability of the engine can be utilized for a maximum of 15 uninterrupted minutes, followed by one hour at C rating operation, or for the duration of the emergency.* Time at full load is not to exceed 5 percent of the duty cycle.* Typical examples are: standby centrifugal water pumps, oil field well servicing, crash trucks, and gas turbine starters.Generator Set Engine Ratings
All ratings shown are subject to manufacturing tolerances of plus or minus three percent.Standby Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 100 or less.* Typical peak demand: 80 percent of the Standby rated kW, with 100 percent of the rating available for the duration of emergency outage* Typical Application: Building Service Standby within an enclosed sheltered environmentPrime Plus 10 Percent Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 500 or less.* Typical peak demand: 80 percent of the Prime Plus 10 Percent rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical applications: Standby, Rental Unit, Power Module, Unreliable Utility, and Interruptible Rates.Prime Rating
* Typical load factor: 60 to 70 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated output is used for less than 10 percent of the operating hours.* Typical applications: Industrial, Pumping, Construction, Peak Shaving, and Cogeneration.Continuous Rating
* Typical load factor: 70 to 100 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated kW is used for less than 100 percent of the operating hours.* Typical application: Base Load, Utility, and Cogeneration.


Parts terminal Volvo Penta:

468825
Terminal screw
468825 Terminal screw
2001; 2001B; 2001AG, D13B-F MG; D13B-E MG; D13B-E MG (FE), TAD1240GE; TAD1241GE; TAD1242GE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1360VE, TAD1361VE, TAD1363VE, TAD1640GE; TAD1641GE; TAD1642GE, TAD1641VE; TAD1
22797159
 
22797159 Terminal block
D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MH; D16C-
21825714
Terminal
21825714 Terminal
4.3GXiE-225-R, 5.0GXiCE-270-R; 5.0GiCE-225-S, 5.0GXiE-270-R, 5.7GiCE-300-R; 5.7GXiCE-320-R, 5.7GiE-300-R; 5.7GXiE-320-R, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE
888003
 
888003 Terminal block, converter
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MH; D16C-B MH; D16C-C MH, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG
21350704
 
21350704 Terminal block
D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG
21256571
 
21256571 Terminal block
D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH
3887416
 
3887416 Terminal, RK-66
D5A-T; D5A-TA; D5A-B TA, TAMD103A, TAMD165A; TAMD165C; TAMD165P, TAMD74A; TAMD74A-A; TAMD74A-B
3842776
 
3842776 Terminal block
D5A-T; D5A-TA; D5A-B TA, TAMD103A, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD74A; TAMD74A-A; TAMD74A-B
Back to top