837267 Timer relay Volvo.Penta
AQD70D; TAMD70D; TAMD70E, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C
Timer
Price: query
Rating:
Compatible models:
Volvo Penta entire parts catalog list:
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
Information:
Table 1
Diagnostic Codes Table    
Description    Conditions which Generate this Code    System Response    
2246-5 Glow Plug Start Aid Relay current below normal     The Electronic Control Module (ECM) has detected current below normal for at least 2 seconds.
The engine is not cranking.     The code is logged.
If equipped, the warning light will come on.
The ECM is unable to activate the relay for the glow plug starting aid.
The glow plugs will not operate or the glow plugs will operate all the time.    
2246-6 Glow Plug Start Aid Relay current above normal     The ECM has detected current above normal for at least 2 seconds.
The engine is not cranking.    The starting aid is used to improve the engine starting when the engine is cold. The engine ECM monitors the coolant temperature and the intake manifold air temperature in order to determine if the glow plugs are required. If the glow plugs are required, the ECM activates
Parts timer Volvo Penta:
844486