838172 Volvo.Penta Tube


838172 Tube Volvo.Penta MD5A; MD5B; MD5C Tube
838172 Tube Volvo Penta
Rating:
68

Buy Tube 838172 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

Compatible models:

MD5A; MD5B; MD5C   Volvo.Penta

Volvo Penta entire parts catalog list:

MD5A; MD5B; MD5C

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
6161-2
Engine Cylinder 1 Pressure : Erratic, Intermittent, or Incorrect 4805-2
Engine Cylinder #1 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the Electronic Control Module (ECM) to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the In Cylinder Pressure Sensor (ICPS) ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6161-3
Engine Cylinder 1 Pressure : Voltage Above Normal 4805-3
Engine Cylinder #1 Pressure Sensor : Voltage Above Normal The sensor signal is detected by the ECM to have a voltage above 4.8 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6161-4
Engine Cylinder 1 Pressure : Voltage Below Normal 4805-4
Engine Cylinder #1 Pressure Sensor : Voltage Below Normal The sensor signal is detected by the ECM to have a below 0.1625 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6162-2
Engine Cylinder 2 Pressure : Erratic, Intermittent, or Incorrect 4806-2
Engine Cylinder #2 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the ECM to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6162-3
Engine Cylinder 2 Pressure : Voltage Above Normal 4806-3
Engine Cylinder #2 Pressure Sensor : Voltage Above Normal The sensor signal is detected by the ECM to have a voltage above 4.8 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6162-4
Engine Cylinder 2 Pressure : Voltage Below Normal 4806-4
Engine Cylinder #2 Pressure Sensor : Voltage Below Normal The sensor signal is detected by the ECM to have a below 0.1625 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6163-2
Engine Cylinder 3 Pressure : Erratic, Intermittent, or Incorrect 4807-2
Engine Cylinder #3 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the ECM to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6163-3
Engine Cylinder 3 Pressure : Voltage Above Normal 4807-3
Engine Cylinder #3 Pressure Sensor : Voltage Above Normal The sensor signal is detected by the ECM to have a voltage above 4.8 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6163-4
Engine Cylinder 3 Pressure : Voltage Below Normal 4807-4
Engine Cylinder #3 Pressure Sensor : Voltage Below Normal The sensor signal is detected by the ECM to have a below 0.1625 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6164-2
Engine Cylinder 4 Pressure : Erratic, Intermittent, or Incorrect 4808-2
Engine Cylinder #4 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the ECM to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6164-3
Engine Cylinder 4 Pressure : Voltage Above Normal 4808-3
Engine Cylinder #4 Pressure Sensor : Voltage Above Normal The sensor signal is detected by the ECM to have a voltage above 4.8 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6164-4
Engine Cylinder 4 Pressure : Voltage Below Normal 4808-4
Engine Cylinder #4 Pressure Sensor : Voltage Below Normal The sensor signal is detected by the ECM to have a below 0.1625 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6165-2
Engine Cylinder 5 Pressure : Erratic, Intermittent, or Incorrect 4809-2
Engine Cylinder #5 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the ECM to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6165-3
Engine Cylinder 5 Pressure : Voltage Above Normal 4809-3
Engine Cylinder #5 Pressure Sensor : Voltage Above Normal The sensor signal is detected by the ECM to have a voltage above 4.8 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6165-4
Engine Cylinder 5 Pressure : Voltage Below Normal 4809-4
Engine Cylinder #5 Pressure Sensor : Voltage Below Normal The sensor signal is detected by the ECM to have a below 0.1625 VDC.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6166-2
Engine Cylinder 6 Pressure : Erratic, Intermittent, or Incorrect 4810-2
Engine Cylinder #6 Pressure Sensor : Erratic, Intermittent, or Incorrect The sensor signal is detected by the ECM to have unstable voltage which exceeds requirements for clean signal processing.
The code is persistently active until the ICPS ECM detects conditions which are no longer abnormal.
The code is logged once returned to a normal circuit health or operating condition.
6166-3
Engine Cylinder 6 Pressure : Voltage Above


Parts tube Volvo Penta:

852228
 
852228 Tube
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, MD11; MD11C; MD11D, MD31A; TMD31A; TMD31B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
954305
Tube
954305 Tube
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; A
943847
Tube
943847 Tube
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200D; AQ200F; 280B,
850209
Tube
850209 Tube
AQ115A; AQ115B; AQ130, MD11; MD11C; MD11D, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
833686
 
833686 Tube
MD1B; MD2B; AQD2B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
838250
Tube
838250 Tube
MD5A; MD5B; MD5C
838149
 
838149 Tube
MD5A; MD5B; MD5C
838371
 
838371 Tube
MD5A; MD5B; MD5C
Back to top