861850 Tube Volvo.Penta
MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B
Tube
Price: query
Rating:
Compatible models:
Volvo Penta entire parts catalog list:
- Lubricating System » 861850
- Lubricating System
MD2010B; MD2020B; MD2030B; MD2040B; MS2L-D; MS2A-D; 120S-D; MS2B-R; MS2A-E; MS2L-E
Information:
Illustration 1 g00104545Attach a "Do Not Operate" warning tag or a similar warning tag to the start switch or to the controls before the engine is serviced or before the engine is repaired. These warning tags (Special Instruction, SEHS7332) are available from your Cat dealer. Attach the warning tags to the engine and to each operator control station. When appropriate, disconnect the starting controls.Do not allow unauthorized personnel on the engine, or around the engine when the engine is being serviced.Engine exhaust contains products of combustion which may be harmful to your health. Always start the engine and operate the engine in a well ventilated area. If the engine is in an enclosed area, vent the engine exhaust to the outside.Cautiously remove the following parts. To help prevent spraying or splashing of pressurized fluids, hold a rag over the part that is being removed.
Filler caps
Grease fittings
Pressure taps
Breathers
Drain plugsUse caution when cover plates are removed. Gradually loosen, but do not remove the last two bolts or nuts that are located at opposite ends of the cover plate or the device. Before removing the last two bolts or nuts, pry the cover loose in order to relieve any spring pressure or other pressure.
Illustration 2 g00702020
Wear a hard hat, protective glasses, and other protective equipment, as required.
When work is performed around an engine that is operating, wear protective devices for ears in order to help prevent damage to hearing.
Do not wear loose clothing or jewelry that can snag on controls or on other parts of the engine.
Ensure that all protective guards and all covers are secured in place on the engine.
Never put maintenance fluids into glass containers. Glass containers can break.
Use all cleaning solutions with care.
Report all necessary repairs.Unless other instructions are provided, perform the maintenance under the following conditions:
The engine is stopped. Ensure that the engine cannot be started.
Disconnect the batteries when maintenance is performed or when the electrical system is serviced. Disconnect the battery ground leads. Tape the leads in order to help prevent sparks.
Do not attempt any repairs that are not understood. Use the proper tools. Replace any equipment that is damaged or repair the equipment.Pressurized Air and Water
Pressurized air and/or water can cause debris and/or hot water to be blown out and could result in personal injury.When pressurized air and/or pressurized water is used for cleaning, wear protective clothing, protective shoes, and eye protection. Eye protection includes goggles or a protective face shield.The maximum air pressure for cleaning purposes must be below 205 kPa (30 psi). The maximum water pressure for cleaning purposes must be below 275 kPa (40 psi).Fluid Penetration
Pressure can be trapped in the hydraulic circuit long after the engine has been stopped. The pressure can cause hydraulic fluid or items such as pipe plugs to escape rapidly if the pressure is not relieved correctly.Do not remove any hydraulic components or parts until pressure has been relieved or personal injury may occur. Do not disassemble any hydraulic components or parts until pressure has been relieved or personal injury may occur. Refer to the OEM information for any procedures that are required to relieve the hydraulic pressure.
Illustration 3 g00687600Always use a board or cardboard when you check for a leak. Leaking fluid that is under pressure can penetrate body tissue. Fluid penetration can cause serious injury and possible death. A pin hole leak can cause severe injury. If fluid is injected into your skin, you must get treatment immediately. Seek treatment from a doctor that is familiar with this type of injury.Containing Fluid Spillage
Care must be taken in order to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the engine. Prepare to collect the fluid with suitable containers before opening any compartment or disassembling any component that contains fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for the following items:
Tools that are suitable for collecting fluids and equipment that is suitable for collecting fluids
Tools that are suitable for containing fluids and equipment that is suitable for containing fluidsObey all local regulations for the disposal of liquids.Asbestos Information
Illustration 4 g00702022Cat equipment and replacement parts that are shipped from Caterpillar are asbestos free. Caterpillar recommends the use of only genuine Cat replacement parts. Use the following guidelines when you handle any replacement parts that contain asbestos or when you handle asbestos debris.Use caution. Avoid inhaling dust that might be generated when you handle components that contain asbestos fibers. Inhaling this dust can be hazardous to your health. The components that may contain asbestos fibers are brake pads, brake bands, lining material, clutch plates, and some gaskets. The asbestos that is used in these components is usually bound in a resin or sealed in some way. Normal handling is not hazardous unless airborne dust that contains asbestos is generated.If dust that may contain asbestos is present, there are several guidelines that should be followed:
Never use compressed air for cleaning.
Avoid brushing materials that contain asbestos.
Avoid grinding materials that contain asbestos.
Use a wet method in order to clean up asbestos materials.
A vacuum cleaner that is equipped with a high efficiency particulate air filter (HEPA) can also be used.
Use exhaust ventilation on permanent machining jobs.
Wear an approved respirator if there is no other way to control the dust.
Comply with applicable rules and regulations for the work place. In the United States, use Occupational Safety and Health Administration (OSHA) requirements. These OSHA requirements can be found in "29 CFR 1910.1001".
Obey environmental regulations for the disposal of asbestos.
Stay away from areas that might have asbestos particles in the air.Dispose of Waste Properly
Illustration 5 g00706404Improperly disposing of waste can threaten the environment. Potentially harmful fluids should be disposed of according to local regulations.Always use leakproof containers when you drain fluids. Do not pour waste onto the ground, down a drain, or into any source of water.
Parts tube Volvo Penta:
827734
827734 Tube
AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, HS25A; HS25A-B; HS25A-C, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B, MD22A; MD22A-A; MD2
3580297
3580297 Tube
D1-13; D1-13B; D1-20, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B
3580529
3580529 Tube
D2-55; D2-55B; D2-55C, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B
3580232
3580470
3580474
861925
3580328