864878 Turbocharger Volvo.Penta
TAMD71B; TAMD73P-A; TAMD73WJ-A
Turbocharger
Price: query
Rating:
Compatible models:
TAMD71B; TAMD73P-A; TAMD73WJ-A
Volvo.Penta
Volvo Penta entire parts catalog list:
Information:
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Open the engine hood.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g00507711
Disconnect two connectors (1) and (2) .
Remove line assemblies (3) and (4) from refrigerant compressor (5) .
Illustration 2 g00507723
Loosen three bolts (6) and move the refrigerant compressor toward the engine.
Remove V-belt (7) from the refrigerant compressor.
Remove four bolts, four washers, and nuts (8) .
Remove the refrigerant compressor from the bracket.Installation Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Illustration 3 g00507723
Install the refrigerant compressor to the bracket.
Install four bolts, four washers, and nuts (8). Do not tighten the bolts and nuts (8) at this time.
Install V-belt (7) to the refrigerant compressor.Note: Check the V-belt tension. Use a Kent Moore Company BT-33-97 gauge.
Move the refrigerant compressor backward to the engine. Tighten three bolts (6), four bolts, and nuts (8) .
Illustration 4 g00507711
Install line assemblies (4) and (3) to refrigerant compressor (5) .
Connect two connectors (2) and (1) .
Evacuate the air conditioner system. Recharge the air conditioner. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Close the engine hood.
Parts turbocharger Volvo Penta:
3802062
3802127
848276
865334
3827008
3825414
3826914
3827914