21664914 V-ribbed belt Volvo.Penta
TAD560VE; TAD561VE; TAD761VE
V
Price: query
Rating:
Compatible models:
TAD560VE; TAD561VE; TAD761VE
Volvo.Penta
Volvo Penta entire parts catalog list:
- AC-Compressor for fan on sep.bracket » 21664914
Information:
Illustration 1 g00601694Note: Push in the button (1) on the latching type solenoid in order to manually shut off the engine. The solenoid cannot be manually latched in the run position for starting. 155-4651 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.39 0.04 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 2.58 0.30 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 155-4652 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.55 1.60 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 10.3 1.0 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Energize-To-Run (ETR) Nonlatching Type
Illustration 2 g00602191 125-5771 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.29 0.03 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 12.0 1.2 ohmsHold in force ... 4.8 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 14.4 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 125-5772 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.15 1.10 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 48.0 4.8 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Wiring Connections For Fuel Shutoff Solenoid
Energize-To-Shutoff (ETS) Latching Type
Illustration 3 g00602209
End view of ETS solenoid
(1) Ground terminal Ground wire size ... 10 gauge (2) Stop terminal Wire size to OFF terminal of keyswitch ... 16 gauge (3) Start terminal Wire size to S (switch) terminal of starter motor ... 10 gaugeEnergize-To-Run (ETR) Nonlatching Type
Illustration 4 g00602232
End view of ETR solenoid
The solenoid that has two wires has no polarity requirements for the wires.
Parts v Volvo Penta:
1542778
1542778 V-clamp
1372, D11A-A; D11A-B; D11A-C, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, DH10A; DH10A 285; DH10A 360, TAD1030P, TAD1140VE; TAD1141VE; TAD1142VE, TAD115
21056629
20800016
20800016 V-belt pulley
TAD550GE; TAD551GE; TAD750GE, TAD560VE; TAD561VE; TAD761VE, TAD734GE, TAD750VE; TAD760VE
21652835
21685865
20846320
20846323
47701760_070