22707521 V-ribbed belt Volvo.Penta
TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
V
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
A-Premium Engine Serpentine Drive Belt Compatible with Blue Bird, Kenworth, Mack & Western Star Cars - Vision School Bus 2009, T2000, CV, LR, MRU, TerraPro, 4800SB, 4900EX, 4900FA, 4900SA, 6900XD
A-Premium [Vehicle Fitment]: Compatible with Blue Bird Vision School Bus 2009 (Water Pump, Alternator and Air Conditioning); Compatible with Kenworth T2000 1999-2000/2002-2003; Compatible with Mack CV 2008 (Fan and Alternator; with Eaton Fan Clutch), LR 2021, MRU 2008 (Fan and Water Pump), TerraPro 2020; Compatible with Western Star 4800SB 2014/2017, 4900EX 2003-2011/2013/2017-2018/2020-2021, 4900FA 2003-2015/2017-2018, 4900SA 2003-2018, 6900XD 2003/2005-2007/2009-2010/2013-2014/2016 || [Reference Number]: K100675HD, 0124894002, 0131893715, 0132731715, 124894002, 131893715, 132731715, 20927804, 21531745, 22696211, 22707521, 2947664, 2947665, 504056043, 5801496097, 7421531741, 7422707520, 88GB458P661 || [Specifications]: ①Belt Material: EPDM; ②Cord Material: Polyester; ③Cross Section Designation: K; ④Effective Length (Inch): 67.49; ⑤Outside Circumference (Inch): 68; ⑥Rib Quantity: 10; ⑦Top Width (Inch): 1.367 || [Advantages]: Made of high temperature and corrosion resistant EPDM material. Stable internal structure helps to improve fuel efficiency and maintain stable engine operation. || [Buy with Confidence]: A-Premium offers a one-year unlimited-mileage guarantee on our meticulously crafted engine serpentine drive belt. We offer a wide variety of automotive accessory categories, ensuring that you can hit the road with peace of mind.
A-Premium [Vehicle Fitment]: Compatible with Blue Bird Vision School Bus 2009 (Water Pump, Alternator and Air Conditioning); Compatible with Kenworth T2000 1999-2000/2002-2003; Compatible with Mack CV 2008 (Fan and Alternator; with Eaton Fan Clutch), LR 2021, MRU 2008 (Fan and Water Pump), TerraPro 2020; Compatible with Western Star 4800SB 2014/2017, 4900EX 2003-2011/2013/2017-2018/2020-2021, 4900FA 2003-2015/2017-2018, 4900SA 2003-2018, 6900XD 2003/2005-2007/2009-2010/2013-2014/2016 || [Reference Number]: K100675HD, 0124894002, 0131893715, 0132731715, 124894002, 131893715, 132731715, 20927804, 21531745, 22696211, 22707521, 2947664, 2947665, 504056043, 5801496097, 7421531741, 7422707520, 88GB458P661 || [Specifications]: ①Belt Material: EPDM; ②Cord Material: Polyester; ③Cross Section Designation: K; ④Effective Length (Inch): 67.49; ⑤Outside Circumference (Inch): 68; ⑥Rib Quantity: 10; ⑦Top Width (Inch): 1.367 || [Advantages]: Made of high temperature and corrosion resistant EPDM material. Stable internal structure helps to improve fuel efficiency and maintain stable engine operation. || [Buy with Confidence]: A-Premium offers a one-year unlimited-mileage guarantee on our meticulously crafted engine serpentine drive belt. We offer a wide variety of automotive accessory categories, ensuring that you can hit the road with peace of mind.
Compatible models:
Volvo Penta entire parts catalog list:
- Belt System » 22707521
- AC-Compressor and Drive Belt
TAD840VE; TAD841VE; TAD842VE; TAD843VE; TAD852VE; TAD851VE; TAD853VE; TAD850-52VE; TAD840-43VE
TAD870VE; TAD871VE; TAD872VE; TAD873VE
Information:
Emergency Stopping
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Buttons
Emergency Stop Button, shown mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). The button requires resetting before the engine will start. Rotate the button in the direction of the arrow on the button's face.
Control Panel Emergency Stop Button.If equipped with a control panel, press the emergency stop button for an emergency stop. The ECS must be reset before resuming operation. Move the ECS to the OFF/RESET position. The ECS can also be used to shut the engine off in an emergency. Move the ECS to the OFF/RESET position. The engine will immediately shut off.Manual Stop Procedure
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.Generator Set Engines
If the ECS is in the AUTO position and the remote contact opens, the engine will run for a pre-programmed cool down period. This will only occur if the cool down mode is used. If the cool down mode is not used, the engine will shut off immediately.1. Open the main electrical circuit breaker to remove the load.2. The engine should be run for a cool down period before being shut off. This can be accomplished with the COOLDOWN STOP function, or the operator can control the cool down and shut off.To use the COOLDOWN/STOP function, turn the ECS to the COOLDOWN/STOP position. The engine will operate for a pre-programmed time period. The timer will activate the fuel shutoff after the cool down period.Alternatively, after removing the load, allow the engine to run at rated speed for one to two minutes. Reduce the speed 1/2 of rated speed for one to two minutes. Reduce the speed to low idle for one to two minutes. Turn the ECS to the OFF/RESET position, and the engine will immediately shut off.Industrial Engines
1. Disengage any driven equipment or remove the load from engine.2. Allow the engine to run at rated speed for one to two minutes.3. Reduce the engine speed to 1/2 rated speed for one to two minutes.4. Reduce the engine speed to low idle for one to two minutes.5. Shut the engine off by turning the START/STOP (ignition) switch to the STOP or OFF position.Alternatively, if equipped with a Mechanical Governor Control, move the control to the FUEL OFF position. Hold the control at the FUEL OFF position until the engine stops.After Stopping the Engine
* Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks on the dipstick.* Repair any leaks, perform minor adjustments, tighten loose bolts, etc.* Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.* Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill.
Only use antifreeze/coolant mixtures recommended in the Cooling System Specifications of this manual. Failure to do so can cause engine damage.
* Allow the radiator and engine jacket water system to cool. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe.If freezing temperatures are expected, check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Buttons
Emergency Stop Button, shown mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). The button requires resetting before the engine will start. Rotate the button in the direction of the arrow on the button's face.
Control Panel Emergency Stop Button.If equipped with a control panel, press the emergency stop button for an emergency stop. The ECS must be reset before resuming operation. Move the ECS to the OFF/RESET position. The ECS can also be used to shut the engine off in an emergency. Move the ECS to the OFF/RESET position. The engine will immediately shut off.Manual Stop Procedure
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.Generator Set Engines
If the ECS is in the AUTO position and the remote contact opens, the engine will run for a pre-programmed cool down period. This will only occur if the cool down mode is used. If the cool down mode is not used, the engine will shut off immediately.1. Open the main electrical circuit breaker to remove the load.2. The engine should be run for a cool down period before being shut off. This can be accomplished with the COOLDOWN STOP function, or the operator can control the cool down and shut off.To use the COOLDOWN/STOP function, turn the ECS to the COOLDOWN/STOP position. The engine will operate for a pre-programmed time period. The timer will activate the fuel shutoff after the cool down period.Alternatively, after removing the load, allow the engine to run at rated speed for one to two minutes. Reduce the speed 1/2 of rated speed for one to two minutes. Reduce the speed to low idle for one to two minutes. Turn the ECS to the OFF/RESET position, and the engine will immediately shut off.Industrial Engines
1. Disengage any driven equipment or remove the load from engine.2. Allow the engine to run at rated speed for one to two minutes.3. Reduce the engine speed to 1/2 rated speed for one to two minutes.4. Reduce the engine speed to low idle for one to two minutes.5. Shut the engine off by turning the START/STOP (ignition) switch to the STOP or OFF position.Alternatively, if equipped with a Mechanical Governor Control, move the control to the FUEL OFF position. Hold the control at the FUEL OFF position until the engine stops.After Stopping the Engine
* Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks on the dipstick.* Repair any leaks, perform minor adjustments, tighten loose bolts, etc.* Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.* Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill.
Only use antifreeze/coolant mixtures recommended in the Cooling System Specifications of this manual. Failure to do so can cause engine damage.
* Allow the radiator and engine jacket water system to cool. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe.If freezing temperatures are expected, check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.
Parts v Volvo Penta:
20712440
21472836
21472836 V-clamp
TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
21531745
21531745 V-ribbed belt
TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
21531751
21531751 V-ribbed belt
TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
22707523
22707523 V-ribbed belt
TAD540-42VE; TAD550-51VE; TAD540VE, TAD570VE; TAD571VE; TAD572VE, TAD840VE; TAD841VE; TAD842VE, TAD870VE; TAD871VE; TAD872VE
20828464
20828464 V-clamp
TAD560VE; TAD561VE; TAD761VE, TAD570VE; TAD571VE; TAD572VE, TAD870VE; TAD871VE; TAD872VE
20739572