966382 V-belt Volvo.Penta
MD22A; MD22A-A; MD22L-A, TD30A; TD31ACE; TD40A
V
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
JRKZRAML Serpentine Belt Compatible with Penta AQ 120 125 131 145 TD 30 31 45 60 70 Engines 966382 958314 841821 Sierra 18-15435
JRKZRAML Engine Compatibility: Fits Penta AQ 120, 125, 131, 145 TD, 30, 31, 45, 60, 70 engines. || Part Number: Designed to replace 966382, 958314, and 841821 Compatible With integration. || Durability: Built to withstand harsh marine conditions Compatible With reliable engine performance. || Easy Installation: Designed Compatible With straightforward installation, saving you time and effort. || Versatile Use: Suitable Compatible With multiple Penta models, enhancing your engine's functionality. || Reliable Performance: Ensures smooth Compatible With your marine engine under various conditions. || Cost-Effective: A practical solution Compatible With maintaining your engine without breaking the bank.
JRKZRAML Engine Compatibility: Fits Penta AQ 120, 125, 131, 145 TD, 30, 31, 45, 60, 70 engines. || Part Number: Designed to replace 966382, 958314, and 841821 Compatible With integration. || Durability: Built to withstand harsh marine conditions Compatible With reliable engine performance. || Easy Installation: Designed Compatible With straightforward installation, saving you time and effort. || Versatile Use: Suitable Compatible With multiple Penta models, enhancing your engine's functionality. || Reliable Performance: Ensures smooth Compatible With your marine engine under various conditions. || Cost-Effective: A practical solution Compatible With maintaining your engine without breaking the bank.
GMkHTLe Serpentine Belt Compatible with AQ 120 125 131 145 TD 30 31 45 60 70 Engines Replacement Compatible with 966382 958314 841821 Sierra 18-15435
GMkHTLe Fit: Designed to match various models Compatible with easy installation and function. || Enhanced Compatibility: Works with multiple engine models, ensuring versatility across different setups. || Efficient : Reduces wear on engine components by providing smooth belt performance. || Corrosion Resistance: Built to withstand harsh marine conditions Compatible with lasting durability. || Quiet Performance: Minimizes noise levels during Compatible with a more pleasant experience on the water.
GMkHTLe Fit: Designed to match various models Compatible with easy installation and function. || Enhanced Compatibility: Works with multiple engine models, ensuring versatility across different setups. || Efficient : Reduces wear on engine components by providing smooth belt performance. || Corrosion Resistance: Built to withstand harsh marine conditions Compatible with lasting durability. || Quiet Performance: Minimizes noise levels during Compatible with a more pleasant experience on the water.
JRKZRAML V-Belt Compatible with Penta D30 D31 D40 D41 D42 D60 D70 D100 D120 Engines 966978 958314 958359 966382 841821
JRKZRAML V-Belt: Designed Compatible With reliable performance on D30, D31, D40, D41, D42, D60, D70, D100, D120 engines. || Compatibility: Fits various models including 966978, 958314, 958359, 966382, and 841821. || Durability: Built to withstand the tough demands of marine environments and engine . || Efficiency: Offers transfer of power, ensuring smooth engine function and improved performance. || Installation: Easy to install, providing a hassle-free solution Compatible With engine maintenance and repairs. || Versatility: Suitable Compatible With a range of Penta engines, enhancing adaptability in various marine setups. || Reliability: Engineered Compatible With consistent performance, supporting safe and efficient boat .
JRKZRAML V-Belt: Designed Compatible With reliable performance on D30, D31, D40, D41, D42, D60, D70, D100, D120 engines. || Compatibility: Fits various models including 966978, 958314, 958359, 966382, and 841821. || Durability: Built to withstand the tough demands of marine environments and engine . || Efficiency: Offers transfer of power, ensuring smooth engine function and improved performance. || Installation: Easy to install, providing a hassle-free solution Compatible With engine maintenance and repairs. || Versatility: Suitable Compatible With a range of Penta engines, enhancing adaptability in various marine setups. || Reliability: Engineered Compatible With consistent performance, supporting safe and efficient boat .
Compatible models:
MD22A; MD22A-A; MD22L-A
TD30A; TD31ACE; TD40A
Volvo.Penta
Volvo Penta entire parts catalog list:
- Extra Alternator » 966382
Information:
Table 1
Diagnostic Trouble Codes
CDL Code and Description Comments
485-5
Engine Fan Reversing Solenoid : Current Below Normal There is an open circuit in the wiring.
Or:
There is an open circuit inside the coil for the fan.
485-6
Engine Fan Reversing Solenoid : Current Above Normal This code is caused by a short circuit in the wiring between the P2 connector and the coils for the fan. The purpose of a reversing fan is to clean debris from the radiator. Temporarily reverse the direction of the air flow through the radiator fins in order to purge debris from the radiator fins. For some applications, the reversing fan is used to heat the engine compartment during cold-weather operation.In the automatic mode, the fan reversing solenoid is controlled by the Electronic Control Module (ECM). The ECM will automatically reverse the direction of the fan rotation. The ECM will use a preset time interval to cycle the fan reversing solenoid.The operator can manually reverse the fan rotation by pressing the engine fan reverse switch. While the momentary switch is depressed, the direction of the fan rotation will reverse. Once the switch is allowed to reset, the fan returns to normal operation and control of the fan will return to the automatic operation.
Illustration 1 g02904976
Schematic for the fan reversing solenoid
Illustration 2 g02167868Test Step 1. Verify Operation of the Engine Fan Reverse Switch
Connect the Caterpillar Electronic Technician (ET) to the service tool connector.
Turn the battery disconnect switch to the ON position.
Turn the keyswitch to the ON position.
Check the status of the engine fan reverse switch, on Cat ET while you operate the switch.
Turn the keyswitch to the OFF position.Results:
The status changes accordingly with the switch position. - Proceed to Test Step 2.
The status does not change with the switch position. - Proceed to Test Step 5.Test Step 2. Check for Active Diagnostic Codes
Turn the keyswitch to the ON position.
Use Cat ET to monitor the active diagnostic code screen. Check and record any active diagnostic codes.Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Determine if the problem is related to an open circuit diagnostic code -5 or a short circuit diagnostic code -6.
Turn the keyswitch to the OFF position.Results:
No diagnostic codes are active. - Repair: The problem may have been related to a faulty connection in the harness. Carefully reinspect the connectors and wiring. If an intermittent electrical problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for information that is related to troubleshooting intermittent problems.STOP
An open circuit diagnostic code -5 is active at this time. - Proceed to Test Step 4.
A short circuit diagnostic code -6 is active at this time. - Proceed to Test Step 3.Test Step 3. Create an Open Circuit at the Connector for the Fan Reversing Solenoid
Disconnect the harness connectors for the fan reversing solenoid.
Turn the keyswitch to the ON position.
Access the "Active Diagnostic Code" screen on Cat ET. Check for an active open circuit diagnostic code -5 for the fan reversing solenoid.Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Turn the keyswitch to the OFF position.Results:
An open circuit diagnostic code -5 became active after disconnecting the connector. - Repair: Temporarily connect a new fan reversing solenoid to the harness, but do not install the new fan reversing solenoid. Verify that there are no active diagnostic codes for the solenoid. If there are no active diagnostic codes for the solenoid, permanently install the new solenoid. Clear any logged diagnostic codes.STOP
The short circuit diagnostic code -6 remained active after disconnecting the connector. - Repair: The short circuit is in the harness between the solenoid connector and the ECM. There may be a problem with the ECM. Refer to Troubleshooting, "ECM - Replace" before replacing the ECM.STOPTest Step 4. Create a Short at the Connector for the Fan Reversing Solenoid
Disconnect the harness connectors at the fan reversing solenoid.
Fabricate a jumper wire that is long enough to create a short circuit across the terminals of the solenoid connector.
Install the jumper wire to the terminals on the harness side of the solenoid connector.
Turn the keyswitch to the ON position.
Monitor the "Active Diagnostic Codes" screen on Cat ET before installing the jumper wire and after installing the jumper wire.Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Remove the jumper wire.
Turn the keyswitch to the OFF position.Results:
The short circuit diagnostic code is active while the jumper wire is installed. - Repair: The engine harness and the ECM are OK. Temporarily connect a new fan reversing solenoid to the harness, but do not install the solenoid. Verify that there are no active diagnostic codes for the new solenoid. If there are no active diagnostic codes for the solenoid, permanently install the new solenoid. Clear any logged diagnostic codes.STOP
The open circuit diagnostic code -5 remains active while the jumper wire is installed at the solenoid connector. - Repair: There is an open circuit in the harness between the ECM and the connector for the fan reversing solenoid. There may be a problem with the ECM. Refer to Troubleshooting, "ECM - Replace" before replacing the ECM.STOPTest Step 5. Short the Harness at the Engine Fan Reverse Switch
Fabricate a jumper wire that can be used to short circuit two terminals at the harness connector for the engine fan reverse switch.
Use the jumper wire to short circuit terminals 2 and 3 together on the harness side of the connector for switch.
Turn the keyswitch to the ON position.
Check the status of the engine fan reverse switch-on Cat ET.Note: Wait at least 30 seconds for activation of the parameter.The correct status for the switch is "On".
Remove the jumper wire from the connector and check the status of the engine fan reverse switch-on Cat ET.Note: Wait at least 30 seconds for the activation of the parameter.Note: The correct status for the switch is "Off".
Turn the keyswitch to the OFF position.
Remove the wire jumper wire. Restore the wiring to the original configuration.Results:
OK - The status changes accordingly.Repair: There is a problem with the
Parts v Volvo Penta:
958359
958359 V-belt
AD30A; AQAD30A; MD30A, AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD40A; TMD40A; TMD40B, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TD30A; TD31ACE; TD40A
966978
966978 V-belt
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, TD30A; TD31ACE; TD40A, TD60D; TD60D-83; TD60DPP-83, TD70G; TD70G-83; TD70GPP, TMD
966912
967162
465145
465145 V-belt pulley
D100A; D100AK; D100B, TD100G; TD100G-85; TD100G-87, TD120HP-86; TD121; TD121G, TD30A; TD31ACE; TD40A, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD61A; TD61AW; TD61ACE, TD70G; TD70G-83; TD70GPP
966993
966993 V-belt
TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1230P; TD121GP-87; TWD1210P, TD120HP-86; TD121; TD121G, TD121G-87; TWD1210V; TWD1211V, TD30A; TD31ACE; TD40A, TWD1230ME
1542448