864983 Volvo.Penta Valve seat, intake


864983 Valve seat, intake Volvo.Penta TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TD610G; TWD610G; TD710G, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P Valve
864983 Valve seat, intake Volvo Penta
Rating:
8

Buy Valve seat, intake 864983 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$26.04
 

02-02-2024

CN: jiaxieting
Replacement for CUB Cadet 941-04298 Bearing Cone Z Force SLT GT LT LX 1042 1045 1046 1050 1554
WEboL
Number on catalog scheme: 2
 

Volvo Penta entire parts catalog list:

TAMD71A; TAMD72A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TD610G; TWD610G; TD710G; TWD710G; TAD730G; TWD740GE; TAD740GE; TAD741GE
TD71A; TID71A; TWD710V; TD730VE; TWD731VE; TAD730V; TWD740VE
TWD610P; TWD610PB; TWD710P; TWD710PB; TAD730P

Information:

References
Reference: Operation Manual, NEHS0678Reference: Specifications for alternator outputReference: Special Instruction, REHS0354, "Charging System Troubleshooting"Required Tools
Table 1
Required Tools
Item Quantity Part Number Part Name
T1 1 225-8266 Ammeter Tool Gp
T2 1 237-5130
or
146-4080 Digital Multimeter Gp
or
Digital Multimeter Gp
T3 1 8T-9293 Torque Wrench
T4 1 261-0444 Adapter
T5 1 2P-8267 Hex Bit Socket
T6 1 8H-8517 Combination Wrench
T7 1 8T-5314 Adapter 225-8266 Ammeter Tool Gp
Illustration 1 g02231196
225-8266 Ammeter Tool Gp
The 225-8266 Ammeter Tool Gp is portable. This ammeter is a self-contained instrument that measures electrical currents without breaking the circuit and without disturbing the conductor insulation.The ammeter contains a digital display that is used to monitor current directly within a range between 1 A and 1200 A. To view current readings of less than 1 A use the multimeter display. In order to read the multimeter display, connect a 6V-6014 Cable between the digital multimeter and the ammeter. The ammeter then sends the current measurement to the multimeter display.A lever opens the ammeter jaws over a conductor. The conductor diameter cannot be larger than 19 mm (0.75 inch).The spring loaded jaws close around the conductor for measuring the current. A trigger switch controls the ammeter. The trigger switch can be locked into the ON position or into the OFF position.After the trigger is turned to the OFF position, the reading appears in the digital display for 5 seconds. This meter accurately measures currents in areas with limited access. For example, these areas include areas that are beyond the sight of the operator. For DC operation, the ammeter contains a zero control. Batteries inside the handle supply the power.Note: Refer to the user manual for more information about using the 225-8266 Ammeter Tool Gp.237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
Illustration 2 g02231214
237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp is a portable, hand-held service tool with a digital display. This multimeter is built with extra protection against damage in field applications. The multimeter is equipped with 7 functions and 29 ranges. The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp has an instant ohms indicator. This indicator permits checking continuity for a fast inspection of the circuits. The multimeter can also be used for troubleshooting capacitors that have small values.Note: Refer to the manual that is provided by the supplier for more information on the use of the 237-5130 Digital Multimeter Gp. Refer to Operation Manual, NEHS0678 for complete information for the use of the 146-4080 Digital Multimeter Gp.Charging System Procedures
Charging System
To check for correct output of the alternator, see the Specifications module. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting". If the part number for the alternator to be tested is not listed in the Special Instruction, refer to the appropriate Specifications manual for the information needed to test the alternator.Before the start of on-engine testing, the charging system and the battery must be checked according to the following steps.
The battery must be at least 75 percent (1.225 Sp Gr) of the full charge. The battery must be held tightly in place. The battery holder must not put too much stress on the battery.
Cables between the battery, the starter, and the engine ground must be the correct size. Wires and cables must be free of corrosion. Wires and cables must have cable support clamps to prevent stress on battery connections (terminals).
Leads, junctions, switches, and panel instruments that have direct relation to the charging circuit must give correct circuit control.
Inspect the drive components for the charging unit to be sure that the components are free of grease and oil. Be sure that the drive components can operate the charging unit.
Check the tension of the belt for the alternator pulley. Refer to the Belt Tension Chart for the correct tension of the belt.Alternator
The charging rate of the alternator should be checked when an alternator is charging the battery too much. The charging rate of the alternator should be checked when an alternator is not charging the battery enough. Make reference to the Specifications module to find all testing specifications for the alternators and regulators.No adjustment can be made to change the rate of charge on the alternator regulators. If the rate of charge is not correct, a replacement of the regulator is necessary.Tightening The Alternator Pulley Nut
Illustration 3 g06502288
Tools for tightening the alternator pulley nut
(T3) 8T-9293 Torque Wrench
(T4) 261-0444 Adapter
(T5) 2P-8267 Hex Bit Socket
(T6) 8H-8517 Combination Wrench (1-1/8 inch)
(T7) 8T-5314 Adapter Socket


Parts valve Volvo Penta:

859171
Valve stem seal
859171 Valve stem seal
2001; 2001B; 2001AG, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42
842972
Valve disc
842972 Valve disc
AD30A; AQAD30A; MD30A, AQD70D; TAMD70D; TAMD70E, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, KAD32P; TAMD42WJ-A; KAD43P-A, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD31A; TMD31A; TMD31B, MD40A; TMD40A; TMD40B, MD70C; TMD70C; TA
466384
Valve spring
466384 Valve spring
AQD70D; TAMD70D; TAMD70E, D70CHC; D70CRC; TD70CHC, MD70C; TMD70C; TAMD70C, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD30A; TD31ACE; TD40A, TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630
466383
Valve spring
466383 Valve spring
AQD70D; TAMD70D; TAMD70E, D70CHC; D70CRC; TD70CHC, MD70C; TMD70C; TAMD70C, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD30A; TD31ACE; TD40A, TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630
465158
Valve seat
465158 Valve seat
TAMD60A; TAMD60B, TAMD60C, TAMD61A; TAMD62A, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TWD610P; TWD610PB; TWD710P
465155
Valve seat
465155 Valve seat
TAMD60A; TAMD60B, TAMD60C, TAMD61A; TAMD62A, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TWD610P; TWD610PB; TWD710P
6212660
 
6212660 Valve
TAMD60C, TD30A; TD31ACE; TD40A, TD610G; TWD610G; TD710G, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE
866699
 
866699 Valve
TAD1230P; TD121GP-87; TWD1210P, TAMD63L-A; TAMD63P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TD100G-87; TD1030ME; TWD1030ME, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD1230M
Back to top