37830-PNC-003 SENSOR ASSY., MAP Honda
BF40DK2 LHA, BF40DK2 LRTA, BF50DK2 LRTA, BF50DK2 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA
SENSOR
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
YANGMO-AUTO 1pc/set OE# 37830-PNC-003 37830PNC003 INTAKE AIR PRESSURE
CAIJUN-AUTO Fast shipping 5-7 DAYS for the delivery || In oder to confirm the parts fitment, you may send VIN or parts number to us || OE# 37830-PNC-003 37830PNC003 || One Year Warranty
CAIJUN-AUTO Fast shipping 5-7 DAYS for the delivery || In oder to confirm the parts fitment, you may send VIN or parts number to us || OE# 37830-PNC-003 37830PNC003 || One Year Warranty
$79.08
27-08-2024
0.1102[0.05] pounds
CN: jiaqidujiqua
1pc/Set 37830-PNC-003 37830PNC003 Intake Pressure Sensor
OQATNXUR If you have any other auto parts needed , please be free to let us help you .
OQATNXUR If you have any other auto parts needed , please be free to let us help you .
Compatible models:
Honda entire parts catalog list:
- INLET MANIFOLD INJECTOR » 37830-PNC-003
- INLET MANIFOLD INJECTOR » 37830-PNC-003
- INLET MANIFOLD INJECTOR » 37830-PNC-003
- INLET MANIFOLD INJECTOR » 37830-PNC-003
- MUFFLER CASE » 37830-PNC-003
- MUFFLER CASE » 37830-PNC-003
- SILENCER CASE THROTTLE BODY » 37830-PNC-003
- MUFFLER CASE » 37830-PNC-003
- MUFFLER CASE » 37830-PNC-003
- MUFFLER CASE » 37830-PNC-003
- SILENCER CASE THROTTLE BODY » 37830-PNC-003
- SILENCER CASE THROTTLE BODY » 37830-PNC-003
Information:
Emergency Stopping
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Buttons
Emergency Stop Button, shown mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). The button requires resetting before the engine will start. Rotate the button in the direction of the arrow on the button's face.
Control Panel Emergency Stop Button.If equipped with a control panel, press the emergency stop button for an emergency stop. The ECS must be reset before resuming operation. Move the ECS to the OFF/RESET position. The ECS can also be used to shut the engine off in an emergency. Move the ECS to the OFF/RESET position. The engine will immediately shut off.Manual Stop Procedure
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.Generator Set Engines
If the ECS is in the AUTO position and the remote contact opens, the engine will run for a pre-programmed cool down period. This will only occur if the cool down mode is used. If the cool down mode is not used, the engine will shut off immediately.1. Open the main electrical circuit breaker to remove the load.2. The engine should be run for a cool down period before being shut off. This can be accomplished with the COOLDOWN STOP function, or the operator can control the cool down and shut off.To use the COOLDOWN/STOP function, turn the ECS to the COOLDOWN/STOP position. The engine will operate for a pre-programmed time period. The timer will activate the fuel shutoff after the cool down period.Alternatively, after removing the load, allow the engine to run at rated speed for one to two minutes. Reduce the speed 1/2 of rated speed for one to two minutes. Reduce the speed to low idle for one to two minutes. Turn the ECS to the OFF/RESET position, and the engine will immediately shut off.Industrial Engines
1. Disengage any driven equipment or remove the load from engine.2. Allow the engine to run at rated speed for one to two minutes.3. Reduce the engine speed to 1/2 rated speed for one to two minutes.4. Reduce the engine speed to low idle for one to two minutes.5. Shut the engine off by turning the START/STOP (ignition) switch to the STOP or OFF position.Alternatively, if equipped with a Mechanical Governor Control, move the control to the FUEL OFF position. Hold the control at the FUEL OFF position until the engine stops.After Stopping the Engine
* Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks on the dipstick.* Repair any leaks, perform minor adjustments, tighten loose bolts, etc.* Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.* Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill.
Only use antifreeze/coolant mixtures recommended in the Cooling System Specifications of this manual. Failure to do so can cause engine damage.
* Allow the radiator and engine jacket water system to cool. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe.If freezing temperatures are expected, check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Buttons
Emergency Stop Button, shown mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). The button requires resetting before the engine will start. Rotate the button in the direction of the arrow on the button's face.
Control Panel Emergency Stop Button.If equipped with a control panel, press the emergency stop button for an emergency stop. The ECS must be reset before resuming operation. Move the ECS to the OFF/RESET position. The ECS can also be used to shut the engine off in an emergency. Move the ECS to the OFF/RESET position. The engine will immediately shut off.Manual Stop Procedure
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.Generator Set Engines
If the ECS is in the AUTO position and the remote contact opens, the engine will run for a pre-programmed cool down period. This will only occur if the cool down mode is used. If the cool down mode is not used, the engine will shut off immediately.1. Open the main electrical circuit breaker to remove the load.2. The engine should be run for a cool down period before being shut off. This can be accomplished with the COOLDOWN STOP function, or the operator can control the cool down and shut off.To use the COOLDOWN/STOP function, turn the ECS to the COOLDOWN/STOP position. The engine will operate for a pre-programmed time period. The timer will activate the fuel shutoff after the cool down period.Alternatively, after removing the load, allow the engine to run at rated speed for one to two minutes. Reduce the speed 1/2 of rated speed for one to two minutes. Reduce the speed to low idle for one to two minutes. Turn the ECS to the OFF/RESET position, and the engine will immediately shut off.Industrial Engines
1. Disengage any driven equipment or remove the load from engine.2. Allow the engine to run at rated speed for one to two minutes.3. Reduce the engine speed to 1/2 rated speed for one to two minutes.4. Reduce the engine speed to low idle for one to two minutes.5. Shut the engine off by turning the START/STOP (ignition) switch to the STOP or OFF position.Alternatively, if equipped with a Mechanical Governor Control, move the control to the FUEL OFF position. Hold the control at the FUEL OFF position until the engine stops.After Stopping the Engine
* Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks on the dipstick.* Repair any leaks, perform minor adjustments, tighten loose bolts, etc.* Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.* Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill.
Only use antifreeze/coolant mixtures recommended in the Cooling System Specifications of this manual. Failure to do so can cause engine damage.
* Allow the radiator and engine jacket water system to cool. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe.If freezing temperatures are expected, check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.
Parts sensor Honda:
35673-ZW5-003
35673-ZW5-003 SENSOR ASSY., WATER (Honda Code 5892336). TEMPERATURE
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
35673-ZY3-003
35673-ZY3-003 SENSOR ASSY., WATER (Honda Code 6991889). TEMPERATURE
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4
37500-PNB-003
37500-PNB-003 SENSOR ASSY., CRANK (Honda Code 6890446).
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4
37880-PLC-004
37880-PLC-004 SENSOR ASSY., AIR TEMPERATURE (Honda Code 6453823). (MATSUSHITA DENSHI)
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4
35700-ZZ5-003
35655-ZY3-C01
35655-ZY3-C01 SENSOR, OXYGEN
BF175AK1 LA, BF175AK1 XA, BF175AK1 XCA, BF175AK2 LA, BF175AK2 XA, BF175AK2 XCA, BF200AK1 LA, BF200AK1 XA, BF200AK1 XCA, BF200AK2 LA, BF200AK2 XA, BF200AK2 XCA, BF225AK1 LA, BF225AK1 XA, BF225AK1 XCA, BF225AK1 XXA, BF225AK1 XXCA, BF225AK2 LA, BF225AK2
37830-RNA-A01
37830-RNA-A01 SENSOR ASSY., MAP
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150AK0 LA, BF150AK0 XA, BF150AK0 XCA, BF150AK2 LA, BF150AK2 XA, BF150AK2 XCA, BF175AK1 LA, BF175AK1 XA, BF175AK1 XCA, BF175AK2 L
35660-ZZ5-013