0389700 JOHNSON GEARCASE AND BRG ASSY


0389700 GEARCASE AND BRG ASSY JOHNSON 25E79R, 35E79A, J25ECIB, J25ECNE, J25RCSA, J35ECSM GEARCASE
0389700 GEARCASE AND BRG ASSY JOHNSON
Rating:
28

Buy GEARCASE AND BRG ASSY 0389700 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$33.00
 

02-02-2020

-: -
Replacement for Westinghouse 03897-00 Light Bulb This Bulb is Not Manufactured by Westinghouse
Replacement For Westinghouse 03897-00 Light Bulb || Volts 130 || Watts 25 || Unit per sale:1
$23.95
 

12-09-2017

Reliable S: Reliable Supply
4 BULBS for WESTINGHOUSE 03897, 038970, 03897-00 LAMP 130VOLTS 25WATTS
25 WATTS||130 VOLTS||T10 SHAPE
Number on catalog scheme: 36
 

Compatible models:

BRP JOHNSON entire parts catalog list:

25E79R, 25EL79R, 25R79R, 25RL79R 1979
35E79A, 35EL79A, 35R79A, 35RL79A 1979
J25ECIB, J25ECIM, J25ELCIB, J25ELCIM, J25RCIM, J25RLCIM, J25TECIM, J25TELCIM 1981
J25ECNE, J25ELCNE, J25RCNB, J25RELCNB, J25RLCNB, J25TECNB 1982
J25RCSA, J25RLCSA, J25TECSA, J25TELCSA 1980
J35ECSM, J35ELCSM, J35RCSM, J35RLCSM 1980

Information:

Electrically Operated Air Shutoff Valves
Power up the engine control panel with both air shutoff valves latched in the open position and both switches connected. Both valves should remain open. Check the wiring for the switch if both valves do not remain open.
With the power to the engine control panel ON, activate the emergency stop button. Both of the air shutoff valves should close. If both air shutoff valves do not close, check the switch wiring and the solenoid wiring. If both air shutoff valves close, proceed to step 3.
Turn the power engine control panel to the OFF position. Ensure that the emergency stop button is in the run position. Latch only the right side air shutoff valve to the open position and turn the power for the engine control panel to the ON position. The right air shutoff valve should close. If the right air shutoff valve closes proceed to step 4. If the right air shutoff valve does not close, check the switch and wiring for the right air shutoff valve.
Turn power for the engine control panel to the OFF position. Ensure that the emergency stop button is in the run position. Latch only the left side air shutoff valve to the open position. Turn the power for the engine control to the ON position. The left air shutoff valve should close. If the left air shutoff valve closes the test is complete. If the left air shutoff valve does not close, check the switch and the wiring for the left air shutoff valve. Note: Testing is only complete when the engine successfully passes step 1 through step 4.Hydraulically Actuated Air Shutoff Valves
Note: After checking the fluids in the engine, ensure that both air shutoff valves are latched in the open position. Start the engine and operate the engine at 1500 RPM. This will allow the fluids to warm up before proceeding with the test for the air shutoff valves.
Manually trip one of the air shutoff valves. This should cause an emergency stop condition and the remaining air shutoff valve should close. If the engine experienced an emergency stop condition but the remaining valve did not close, purge the air from the line that goes to the hydraulic cylinder for the air shutoff valve. If the engine did not have an emergency stop condition the switches are not correctly wired into the emergency stop circuit. Note: Both switches should be in a closed state and both switches should show continuity when the air shutoffs are latched in the open position. After the issue with the wiring has been resolved repeat step 1.
Close one air shutoff valve and attempt to start the engine. If the engine cranks but the engine will not start, the switches are functioning correctly. Caterpillar Electronic Technician (ET) will also show an active emergency stop condition. Proceed to step 3. If the engine starts with one of the air shutoffs closed, check the switch on the valve that is closed. The switch should not have continuity. If the switch has continuity, remove the switch and inspect the switch. If the switch does not show continuity, troubleshoot the switch wiring further. Repair the necessary components or replace the necessary components. Retest the system, as required.
With both air shutoff valves in the open position, activate the emergency stop. Both air shutoff valves should close. If both valves close, testing is complete. If only one air shutoff closes, purge air from the line at the cylinder that failed to close and repeat this step. Note: Testing is only complete when the engine successfully passes all of the steps. Reset both air shutoff valves to the open position and clean up any spills that may have occurred.Note: The limit switch assemblies are items that wear and the limit switch assemblies may need to be replaced during normal maintenance intervals.


Parts gearcase JOHNSON:

0389045
 
0389045 GEARCASE HEAD ASSY
25E78C, 25E79R, 35E78R, 35E79A, D25RWA, HJ25FPO, HJ25FPV, J25ECIB, J25ECNE, J25ECRS, J25ECTD, J25RCSA, J25RSA, J25RSLS, J25RWCDC, J25RWCOS, J25RWCRD, J25RWCUR, J25RWEIM, J25RWENB, J25RWEOS, J25RWERD, J25RWESA, J25RWETE, J25RWK, J28ELCDS, J28ELCDS, J2
0389729
 
0389729 GEARCASE, Bearing and seal
25E78C, 25E79R, 35E78R, 35E79A
0389730
 
0389730 GEARCASE ASSY
25E78C, 25E79R, 35E78R, 35E79A
0390349
0390383
 
0390383 GEARCASE ASSY.
J25RCSA, J35ECIG, J35ECSM
Back to top