0325669 JOHNSON THRUST WASHER


0325669 THRUST WASHER JOHNSON BJ3REDS, BJ4BREDS, BJ4BREUC, J2RTSIA, J2WRSIR, J3BRCEC, J3BRESR, J3RCCM, J3RCUA, J3REIA, J3RENM, J3REOD, J3RERE, J3RETB, J3REUC, J3RSDE, J3RSNF, J3RSOD, J3RSRE, J3RSTB, J3RTLSIA, J3WRSIR, J4BRCIC, J4BRECRJ, J4BRHCCS, J4BRHCDE, J4BRHCNR, J4BRHCOB, J4B THRUST
0325669 THRUST WASHER JOHNSON
Rating:
58

Buy THRUST WASHER 0325669 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 24
 

BRP JOHNSON entire parts catalog list:

BJ3REDS, SJ3REDS 1996
BJ4BREDS, BJ4BRLEDS, BJ4REDS, BJ4RLEDS, J4REDS, J4RLEDS, SJ4REDS, SJ4RLEDS 1996
BJ4BREUC, BJ4BRLEUC, J4REUC, J4RLEUC 1997
J2RTSIA, J2RTVSIA 2001
J2WRSIR 2001
J3BRCEC 1989
J3BRESR 1990
J3RCCM 1988
J3RCUA 1987
J3REIA 1991
J3RENM 1992
J3REOD 1995
J3RERE 1994
J3RETB 1993
J3REUC 1997
J3RSDE 2006
J3RSNF 2002
J3RSOD 2005
J3RSRE 2004
J3RSTB, J3RSTF 2003
J3RTLSIA, J3RTSIA, J3RTVSIA 2001
J3WRSIR 2001
J4BRCIC, J4BRLCIC 1981
J4BRECRJ, J4BRLECRJ 1998
J4BRHCCS, J4BRHLCCS 1988
J4BRHCDE, J4BRHLCDE 1986
J4BRHCNR, J4BRHLCNR 1982
J4BRHCOB, J4BRHLCOB 1985
J4BRHCRM, J4BRHLCRM 1984
J4BRHCTA, J4BRHLCTA 1983
J4BRHCUD, J4BRHLCUD 1987
J4RCCS, J4RLCCS 1988
J4RCEC, J4RLCEC 1989
J4RCUD, J4RLCUD 1987
J4REEA, J4RLEEA 1999
J4REIA, J4RLEIA 1991
J4RENM, J4RLENM 1992
J4REOD, J4RLEOD 1995
J4RERE, J4RLERE 1994
J4RESR, J4RLESR 1990
J4RETB, J4RLETB 1993
J4RLSIB, J4RSIB 2001
J4RLSSM, J4RSSM 2000

Information:


Table 1
Diagnostic Codes Table    
Description     Conditions which Generate this Code     System Response    
268-2 Check Programmable Parameters     The engine Electronic Control Module (ECM) detects that one or more of the programmable parameters have not been programmed.     The ECM may use a default torque map or the ECM may limit the engine to low idle.
The code is active only.    
253-2 Personality Module mismatch     The flash file in the engine ECM is for a different type of engine. The interlock code in the non-volatile memory does not match the flash file.
or
The flash file is not compatible with the ECM.     The interlock for the personality module code must be set to zero in order to reset the code. Factory passwords are required to change the interlock code.
The code is active only. The engine may not run.    
1495-2 Injector Trim Codes Not Programmed     The engine ECM detects that one or more of the injector trim codes have not been programmed.     The ECM may use a default torque map or the ECM may limit the engine to low idle.
The code is active only.    Some system configuration parameters are configurable by the customer in order to suit the customer particular application. The configuration file contains all of the adjustable settings for the monitoring system. The engine is shipped from the factory with default values for these parameters. In most cases, the parameters do not require change. The system configuration parameters must be reprogrammed if an ECM is replaced and/or the engine rating is reprogrammed. System configuration parameters remain the same if the flash file is replaced. Proper values for these parameters are available on Caterpillar Electronic Technician (ET). Certain configuration parameters are also stamped on the engine information plate.If the default settings for the parameters have been modified, there will be no record at the factory of the changes. These settings can be downloaded into a laptop computer and saved to a file. The customer can then use the file in order to ease the future replacement of the ECM.Note: Changing the parameters that are protected by factory passwords may cause your Caterpillar warranty to be voided.Check Programmable Parameters (268-02)
If a programmable parameter has not been programmed, the ECM will activate a 268-02 Check Programmable Parameters diagnostic code. The unprogrammed parameters will be set to default. Certain aspects of the engine performance and engine monitoring may be affected.Personality Module Mismatch (253-02)
The ECM stores a code number in permanent memory. This code is called an interlock code that is associated with each flash file. The interlock code does not allow the engine to run if the wrong flash file has been downloaded into the ECM.Cat ET will warn you if a flash file that does not match the last file in the ECM has been downloaded. The interlock code must be reprogrammed with Cat ET in order to allow the engine to run with new software. Installing the incorrect flash file into the ECM may void the Caterpillar warranty.When the engine is rerated, programming the interlock code to zero will prompt the ECM. The ECM will read the stored code and the ECM will match the stored code to the new interlock code.Injector Trim Codes Not Programmed (1495-2)
The engine ECM detects that one or more of the injector trim codes have not been programmed. The injector code is a number that is found on each of the unit injectors. The ECM uses this number to compensate for manufacturing variations between individual injectors. If you replace any of the unit injectors, reprogram the code for the new injectors. Also, if you replace the ECM, reprogram all of the injector codes.Note: The injector codes are not part of the "Configuration" screen on the electronic service tool. "Injector Codes Calibration" can be found under "Calibrations" in the "Service" menu on the electronic service tool.Parameter Descriptions
Engine Serial Number
Program the engine serial number to match the engine information plate. The serial number is not programmed on a new ECM.Rated Fuel Position
This parameter is used to set engine power. A factory password is required to change this setting.
Table 2
Minimum     Default     Maximum    
Minimum Rack     Engine Dependent     Engine Dependent    Desired Speed Input
The desired speed input defines the type of signal that is used for the throttle control. A numeric value is used by Cat ET to set the input for the ECM. The following inputs are available:
A PWM input is defined by the value of 134
A J1939 CAN input is defined by the value of 539Low Idle
The parameter defines the lowest rpm level.
Table 3
Minimum     Default     Maximum    
700 rpm     700 rpm     1000 rpm    High Idle
The parameter defines the highest rpm level.
Table 4
Minimum     Default     Maximum    
1875 rpm     1950 rpm     1950 rpm    Cooldown Speed
This parameter defines the engine speed when the engine is in cooldown mode.
Table 5
Minimum     Default     Maximum    
450 rpm     600 rpm     1800 rpm    Engine Cooldown Duration
This parameter defines engine operation at the cooldown speed. Programming this parameter to 0 will disable this function.
Table 6
Minimum     Default     Maximum    


Parts thrust JOHNSON:

0391065
 
0391065 THRUST BEARING ASSY
BJ3REDS, BJ4BREDS, BJ4BREUC, J2RTSIA, J2WRSIR, J3BRCEC, J3BRESR, J3RCCM, J3RCUA, J3REIA, J3RENM, J3REOD, J3RERE, J3RETB, J3REUC, J3RSDE, J3RSNF, J3RSOD, J3RSRE, J3RSTB, J3RTLSIA, J3WRSIR, J4BRCIC, J4BRECRJ, J4BRHCCS, J4BRHCDE, J4BRHCNR, J4BRHCOB, J4B
0381791
 
0381791 THRUST BEARING ASSY
BJ3REDS, BJ4BREDS, BJ4BREUC, J2RTSIA, J2WRSIR, J3BRCEC, J3BRESR, J3RCCM, J3RCUA, J3REIA, J3RENM, J3REOD, J3RERE, J3RETB, J3REUC, J3RSDE, J3RSNF, J3RSOD, J3RSRE, J3RSTB, J3RTLSIA, J3WRSIR, J4BRCIC, J4BRECRJ, J4BRHCCS, J4BRHCDE, J4BRHCNR, J4BRHCOB, J4B
0115009
 
0115009 THRUST WASHER
BJ2REDE, BJ2REUD, BJ3ROEDE, BJ3ROEUD, HJ2DRETC, HJ3REIC, HJ3RENR, HJ3RETC, J2RECS, J2REEC, J2ROEOB, J2WREES, J2WRSIR, J2WRSSC, J3REEC, J3ROECS, J3ROEOB, J3WREES, J3WRSIR, J3WRSSC
0115531
 
0115531 THRUST WASHER
BJ2REDE, BJ2REUD, BJ3ROEDE, BJ3ROEUD, HJ2DRETC, HJ3REIC, HJ3RENR, HJ3RETC, J2RECS, J2REEC, J2ROEOB, J2RTSIA, J2RTSSR, J2WREES, J2WRSIR, J2WRSSC, J3REEC, J3ROECS, J3ROEOB, J3RSDE, J3RSNF, J3RSOD, J3RSRE, J3RSTB, J3RTLSIA, J3RTLSSR, J3WREES, J3WRSIR, J
0335783
 
0335783 THRUST WASHER, Rod to piston
BJ3REDS, BJ4BREDS, BJ4BREUC, BJ4RDHEDS, J3REIA, J3RENM, J3REOD, J3RERE, J3RETB, J3REUC, J4BRECRJ, J4RDHEIA, J4RDHENM, J4RDHEOD, J4RDHERE, J4RDHETB, J4REEA, J4REIA, J4RENM, J4REOD, J4RERE, J4RETB, J4RLSIB, J4RLSSM
Back to top