43298A 2 Mercury CAP ASSEMBLY


43298A 2 CAP ASSEMBLY Mercury 1115473WD, 11354120D, 1135412GD, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1135473UD, 1135473VD, 1135726, 1150413SD, 1150413VD, 1150413WD, 1150453BD, 1150453GD, 1150453JD, 1150625, 1150628, 1175412GD, 1175413LD, 1175413MD, 1175626, 1200412GD, 12004 CAP
43298A 2 CAP ASSEMBLY Mercury
Rating:
68

Buy CAP ASSEMBLY 43298A 2 Mercury genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$38.78
 

22-02-2024
0.1873[0.08] pounds
US: LEADERS RPM
Mercury - Mercruiser Cap Assy, 36-43298A-2
Mercury Marine
Number on catalog scheme: 4
 

Mercury entire parts catalog list:

1115473WD 2000
11354120D 1990,1991
1135412GD 1989
1135412MD 1992,1993,1994,1995
1135412SD 1996,1997,1998
1135412VD 1999
1135412WD 2000,2001,2002,2003,2004,2005
1135473UD 1998
1135473VD 1999
1135726 1986,1987,1988
1150413SD 1996,1997,1998
1150413VD 1999
1150413WD 2000,2001
1150453BD 1988
1150453GD 1989
1150453JD 1990
1150625 1985
1150628 1978,1979,1980,1982,1983,1984,1985
1175412GD 1989
1175413LD 1991
1175413MD 1992,1993,1994,1995
1175626 1976,1977,1978,1979,1980,1985,1986,1988
1200412GD 1989,1990
1200413GD 1989,1990
1200453EY 2006
1200453HY 2006
1200473TD 1997
1200473UD 1998
1200473VD 1999
1200473WD 2000
1200628 1978,1979,1980,1982,1983,1984,1985,1986,1987,1988
1200D73AD 2003
1200D73CD 2004,2005,2006
1200D73ET 2006,2007,2008
1200D73HT 2006
1200E73EY 2006,2007
1200E73HY 2006
1220727 1987,1988
1225412PD 1994,1995,1996,1997,1998
1225412VD 1999,2000,2001
1225413EY 2007
1225413RD 1995,1996,1997,1998
1225423EY 2007
1225424EY 2007
1225E73AD 2003,2004,2005,2006
1250413UE 1998,1999,2000,2001
1250422GD 1989,1990,1991,1992,1993,1994
1250424EY 2007,2009
1250433EY 2007
1250434EY 2007
1256413WD 2000,2001,2002

Information:

Voltage
The ECM automatically warns the operator of low system voltage. The default settings that are programmed at the factory are listed in Table 1.
Table 1
Voltage Monitoring
Parameter Default Setting
Warning setpoint 20 volts
Warning delay 10 seconds
Hysteresis 2 volts
Security level No required password If the voltage is below 20 volts for 10 seconds, a warning will occur. To deactivate the warning, the voltage must rise above 22 volts.The setpoint can be programmed to a value between 20 and 22 volts.Engine Oil Pressure
The ECM automatically performs the following functions for low engine oil pressure:
Warning
ShutdownThe strategy is based on a map of the engine oil pressure versus the engine rpm. For engines that are rated up to 1300 rpm, see Illustration 1. For engines that are rated at 1301 rpm and above, see Illustration 2. The default settings that are programmed at the factory are listed in Table 2.
Table 2
Engine Oil Pressure
Parameter Default Settings
Upper oil pressure limit 175 kPa (25 psi)
Lower oil pressure limit 41 kPa (5.9 psi)
Hysteresis 40 kPa (5.8 psi)
Activation delay 10 seconds
Security level Required password
Warning setpoint Map
Warning delay 4 seconds
Shutdown setpoint Map
Shutdown delay 9 seconds
Illustration 1 g00570830
Map of the engine oil pressure versus the engine rpm for engines that are rated up to 1300 rpm
(Y) Engine oil pressure in kPa
(X) Engine rpm
(1) Hysteresis
(2) Minimum engine oil pressure
Illustration 2 g00592294
Map of the engine oil pressure versus the engine rpm for engines that are rated at 1301 rpm and above
(Y) Engine oil pressure in kPa
(X) Engine rpm
(1) Hysteresis
(2) Minimum engine oil pressureIf the engine oil pressure is below the minimum pressure for four seconds, a warning will occur. To deactivate the warning, the engine oil pressure must rise above the hysteresis that is set in the map.If the engine oil pressure is below the minimum pressure for nine seconds, a shutdown will occur.The map cannot be reprogrammed.High Coolant Temperature
The ECM will automatically perform the following functions for high coolant temperature:
Warning
Derating
ShutdownThe default settings that are programmed at the factory are listed in Table 3.
Table 3
High Coolant Temperature
Parameter Default Setting
Warning setpoint 102 °C (216 °F)
Warning delay 5 seconds
Derate setpoint 107 °C (225 °F)
Derate delay 30 seconds
Maximum time of derating 480 seconds
Hysteresis 5 °C (9 °F)
Security level Required password
Maximum derating 25%
Shutdown setpoint 107 °C (225 °F)
Shutdown delay 5 seconds If the coolant temperature is above 102 °C (216 °F) for five seconds, a warning will occur. The coolant temperature must be below 97 °C (207 °F) in order to deactivate the warning.If the coolant temperature is above 107 °C (225 °F) for 30 seconds, a derating will occur. A continuous 25 percent derating is reached in 480 seconds. When the coolant temperature is less than 102 °C (216 °F), the percent of the derating decreases. The percent of the derating decreases until the capability of providing full power is restored. However, if the coolant temperature rises above the setpoint again, the derating will resume.If the coolant temperature is above 107 °C (225 °F) for five seconds, a shutdown will occur.Note: The default setting for the delay of the derating is programmed to the maximum value of 30 seconds. The delay for the shutdown is five seconds. These settings result in a shutdown that occurs before a derating. These settings are programmed because most customers prefer a shutdown for high coolant temperature. The settings can be programmed to different values.The setpoint can be programmed in the range of 90 to 102 °C (194 to 215 °F).Low Coolant Temperature
The ECM will automatically warn the operator of low coolant temperature. The default settings that are programmed at the factory are listed in Table 4.


Parts cap Mercury:

53078
 
53078 CAP, PLASTIC - TILT TUBE
1018200, 1025200, 1035204, 1040200, 1040208, 1045217, 1050200, 1060504, 1070500, 1080500, 1080508, 1090528, 1115100, 1115503, 1115525, 1115528, 1135100, 1140528, 1140629, 1150503, 1150538, 1150625, 1400100, 1402202, 1402205, 1500100, 1500101, 1500205
26852
 
26852 CAP, NYLON - ADJUSTING SCREW
1035204, 1035207, 1040200, 1040208, 111047JHD, 1115473WD, 11354120D, 1135412GD, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1135473UD, 1135473VD, 1135473YD, 1135726, 1135D73CD, 1135D73FT, 1150413CD, 1150413FY, 1150413HF, 1150413HY, 1150413SD, 1150413
48039
 
48039 CAP, THROTTLE ACTUATOR ADJUSTING SCREW
1018200, 1018204, 1020201BC, 1025200, 1035204, 1035207, 1040200, 10402139D, 1045217, 1050200, 1050312BC, 1060504, 1070500, 1075524, 1080500, 1080508, 1090520, 1090524, 1100312BD, 1100412PD, 1100412VB, 1115412DB, 1115520, 1115523, 1115525, 11354120D,
52023
 
52023 CAP, NYLON - STOP BRACKET ADJUSTING SCREWS
1050312BC, 1060504, 1070500, 1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625, 1150628, 1175626, 1200628, 1225620, 1250422GD, 130
810779
CAP
810779 CAP
11354120D, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1150453JD, 1225412PD, 1225412VD
823865
CAP PLUG
823865 CAP PLUG
1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412FF, 1090412FY, 1090422DY, 1090422FF, 1090472D
814449A 2
 
814449A 2 CAP ASSEMBLY
1225412PD, 1225413RD
814449A 3
CAP ASSEMBLY
814449A 3 CAP ASSEMBLY
1200453CD, 1200453EY, 1200453HY, 1200473TD, 1200473UD, 1200473VD, 1200473WD, 1200473YD, 1225412PD, 1225412VD, 1225413EY, 1225413RD, 1225413ZD, 1225423EY, 1225424EY, 1250413CD, 1250413UE, 1250424EY, 1250433EY, 1250434EY, 1256413WD
Back to top