71663 Mercury PLUG, HARNESS


71663 PLUG, HARNESS Mercury 1006201DB, 1006201PD, 1006201VB, 1006206, 1006211RD, 1007208, 1007209, 1008211RD, 1010207VB, 1010208, 1011201DB, 1016207PD, 1018200, 1018204, 1020201BC, 1020208, 1025200, 1075204, 1110204, 1200203 PLUG
71663 PLUG, HARNESS Mercury
Rating:
73

Buy PLUG, HARNESS 71663 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 23
 

Mercury entire parts catalog list:

1006201DB 2005,2006
1006201PD 1994,1995,1996,1997,1998
1006201VB 1999,2000,2001,2002,2003,2004
1006206 1986,1987,1988,1989,1990,1991,1992,1993,1994
1006211RD 1995
1007208 1978
1007209 1979,1980,1981,1982,1983,1984,1985
1008211RD 1995
1010207VB 1999,2000,2001,2002,2003,2004
1010208 1978
1011201DB 2005,2006
1016207PD 1994
1018200 1980,1982,1983
1018204 1984,1985,1986,1987
1020201BC 1988,1989,1990,1991,1992,1993,1994
1020208 1978,1979,1980
1025200 1980,1982,1983
1075204 1974,1975,1976,1977
1110204 1974,1975,1976,1977
1200203 1973,1974,1975,1976,1977

Information:


Illustration 1 g00813712
Schematic
Illustration 2 g01007882
P1 ECM connectorTest Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector and all other connectors in the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points. All connections and grounds are tight and free of corrosion.Results:
OK - The connectors and the wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or the wiring.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Resistance through the Solenoid
Disconnect the J508/P508 fan control solenoid connector.
Measure the resistance of the sensor between J508:1 (Fan Control Solenoid) and J508:2 (Solenoid Return).Expected Result:The resistance is between 4.5 and 5.5 Ohms.Results:
OK - The resistance is between 4.5 and 5.5 Ohms. Proceed to Test Step 4.
Not OK - There may be a problem with the fan control solenoid. Proceed to Test Step 3.Test Step 3. Temporarily Install a New Fan Control Solenoid
Remove the fan control solenoid.
Temporarily install a new fan control solenoid.
Connect the Caterpillar Electronic Technician (Cat ET) to the service tool connector.
Turn the keyswitch to the ON position.
Clear any logged diagnostic codes on Cat ET.
Start the engine.
Check for diagnostic codes for the engine fan control solenoid on Cat ET.
Ensure that the engine fan control solenoid is working properly.
Turn the keyswitch to the OFF/RESET position.Expected Result:The engine fan control solenoid is working properly and there are no active diagnostic codes for the engine fan control solenoid.Results:
OK - The fan control solenoid was faulty.Repair: Permanently install the new fan control solenoid.Verify that the repair eliminates the problem.STOP
Not OK - There may be a problem with the harness. Proceed to Test Step 4.Test Step 4. Check for Shorts in the Harness
Disconnect the J1/P1 ECM connector and the J508/P508 fan control solenoid connector.
Measure the resistance between P1:43 (Fan Control Solenoid) and chassis ground.
Measure the resistance between P1:51 (Solenoid Return) and chassis ground.
Measure the resistance between P1:43 (Fan Control Solenoid) and P1:51 (Solenoid Return).Expected Result:The resistance for each measurement is greater than 20,000 Ohms.Results:
OK - The resistance for each measurement is greater than 20,000 Ohms. Proceed to Test Step 5.
Not OK - There is a short between the ECM and the fan control solenoid.Repair: Repair the circuit.STOPTest Step 5. Check for Open Circuits in the Harness
Ensure that the keyswitch is in the OFF/RESET position and that the J1/P1 ECM connector is disconnected.
Use a suitable piece of wire to short P1:43 (Fan Control Solenoid) and P1:51 (Solenoid Return).
Disconnect the J508/P508 fan control solenoid connector.
Measure the resistance between P508:1 (Fan Control Solenoid) and P508:2 (Solenoid Return).Expected Result:The resistance is less than 10 Ohms.Results:
OK - The resistance is less than 10 Ohms. Proceed to Test Step 6.
Not OK - There is an open circuit in the wiring harness between the fan control solenoid and the ECM.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 6. Measure the Current to the Fan Control Solenoid
Reconnect the J1/P1 ECM connector.
The J508/P508 fan control solenoid connector should still be disconnected. Install a jumper wire between J508:2 and P508:2.
Connect an ammeter that is capable of withstanding a 5 amp current between J508:1 and P508:1.
Start the engine and observe the reading on the ammeter that is installed in the circuit.
Turn the keyswitch to the OFF/RESET position.
Remove the ammeter and the jumper wire from the circuit and reconnect the J508/P508 fan control solenoid connector.Expected Result:The ECM is supplying between 0.3 and 1.6 amp to the fan control solenoid.Results:
OK - The ECM appears to be supplying the correct current to the solenoid. Either the pump or the motor may not be responding correctly.Repair: Troubleshoot the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System".STOP
Not OK - The ECM may not be producing a valid supply.Repair: Verify your results.Replace the ECM. Refer to Troubleshooting, "Replacing the ECM" before replacing the ECM.Verify that the repair eliminates the problem.STOP


Parts plug Mercury:

32298
 
32298 PLUG, DRIVE SHAFT HOUSING STUD
1020100, 1020202, 1020208, 10754120D, 1200203
48750
 
48750 PLUG, GEAR HOUSING FLUSHING
1020100, 1020202, 1020208, 1115100, 1115503, 1115525, 1135100, 1150503, 1150538, 1150625, 1200203, 1400100, 1402202, 1402205, 1500100, 1500101, 1500205, 1650100, 1650502, 1650503, 1800100, 1850503, 1850506
32297
 
32297 PLUG, PLASTIC - WATER PICK-UP HOLE
1020208, 1040206, 1115100, 1135100, 1400100, 1650100, 1650502, 1800100
52644
 
52644 PLUG, GREASE - REVERSE LOCK HOLE
1007208, 1010208, 1040206, 1075204, 1110204, 1400100, 1500100
12154
 
12154 PLUG, BOTTOM COWL (MANUAL)
1006201DB, 1006201PD, 1006201RB, 1006201VB, 1006206, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD, 1016207RB
12153 2
PLUG, BOTTOM COWL (ELECTRIC)
12153 2 PLUG, BOTTOM COWL (ELECTRIC)
1006201DB, 1006201PD, 1006201VB, 1006206, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD
17230
 
17230 PLUG, STOP SWITCH HOLE
1006201DB, 1006201VB, 1010207VB, 1011201DB, 10202014D, 1020201BC, 1020201DB, 1020201VB, 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412D
15061001
Back to top