13540 Mercury CAP


13540 CAP Mercury 1006201DB, 1006201VB, 1015203FL, 1020201DB, 1020201VB, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031203PD, 1031203UD, 1041312UB, 1075D73HY, 111047JHD, 1115P73HY, 1115P73H CAP
13540 CAP Mercury
Rating:
23

Buy CAP 13540 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 43
 

Mercury entire parts catalog list:

1006201DB 2005,2006
1006201VB 1999,2000,2001,2002,2003,2004
1015203FL 2006
1020201DB 2005,2006
1020201VB 1999,2000,2001,2002,2003,2004
1025207FL 2006
1025207FM 2006
1025217FL 2006
1025217FM 2006,2010
1030201FL 2006
1030211FL 2006
1030271HL 2006
1030302FL 2006
1030312FL 2006
1030A01FL 2006
1030A11FL 2006
1031203PD 1994,1995,1996,1997,1998,1999
1031203UD 1998,1999
1041312UB 1998
1075D73HY 2006
111047JHD 2006
1115P73HY 2009
1115P73HY 2006
1135473YD 2001,2002,2003
1135D73CD 2004,2005
1135D73FT 2006
1150413CD 2004,2005
1150413FY 2006
1150413HF 2010
1150413HY 2006
1150413ZD 2002,2003
1150423FG 2006
1150423FY 2006
1150423HF 2010
1150423HG 2006
1150423HY 2006
1150424FY 2006
1150424HY 2006
1200413FY 2006
1200413HY 2006
1200423FG 2006
1200423FY 2006
1200423HG 2006
1200423HY 2006
1200424FY 2006
1200424HY 2006
1200453CD 2004,2005,2006
1200453EY 2006
1200453HY 2006
1200473YD 2001,2002
1200D73AD 2003
1200D73CD 2004,2005,2006
1200D73ET 2006,2007,2008
1200D73HT 2006
1200E73EY 2006,2007
1225412VD 1999,2000,2001
1225413EY 2007
1225413ZD 2002,2003
1225423EY 2007
1225424EY 2007
1250413CD 2004,2005
1250424EY 2007,2009
1250433EY 2007
1250434EY 2007
1F10203VD 1999,2000,2001,2002,2003,2004,2005
1F10352VD 1999
1F13203FB 2006
1F15201UD 1998
1F50352VD 1999,2000
1F50412RD 1995,1996,1997,1998
1F51452YB 2001

Information:


Illustration 1 g00867065
Tools that are required in order to measure the air pressure during the calibration of the wastegate actuator (A) Air pressure regulator (B) Air pressure gauge (C) Tee or cross (D) Hose barb coupler (E) Valve for use with cross (F) Valve (G) Fitting for connection to the air supply (H) Test hose 161-6960 (J) 161-6963 Clamps (Hose)The following part will be required in order to replace the wastegate actuator, if necessary.
A 225-0319 Actuator Kit A crimping tool 213-4269 will also be required at final installation.
Inspect the lines for the wastegate solenoid for any signs of damage. Repair the damage as it is necessary.
Disconnect the hose from the wastegate diaphragm.
Apply 138.1 kPa (20.03 psi) of air to the wastegate diaphragm.
Observe the movement of the dial indicator needle. The measurement of the movement of the actuator rod should be 1.0 mm (0.039 inch).Note: Inspect the wastegate for damage if the wastegate is not within specifications. Replace the wastegate if the movement of the actuator rod is not within specifications.Determine the Actuation Calibration Reading
Allow the turbocharger to cool.
Illustration 2 g00918362
Install dial indicator (1) on the engine. The travel of the dial indicator must align with the travel of the rod (2) or an error in the measurement will occur. Refer to Illustration 2.
Remove the hose (4) from the actuator (3) .
Illustration 3 g00918469
Connect the air supply to the air pressure regulator (A) .
Connect the test hose (H) to the actuator (3) with hose clamps (J) .
Turn the knob on air pressure regulator (A) and slowly increase the air pressure while you observe the dial indicator (1). Increase the air pressure until the travel of the rod (2) is 1.00 mm (0.039 inch). Observe the pressure gauge (B) and record the pressure reading.
Turn the knob on air regulator (A) and slowly decrease the pressure to 0 kPa (0 psi). Repeat Step 6. Observe the pressure gauge (B) and record the pressure reading.
This pressure reading is the Actuator Calibration Reading.The Actuation Calibration Reading is Above 128 kPa (18.5 psi)
No further action is necessary if the actuator calibration reading is above 128 kPa (18.5 psi). Remove the test hose and all test equipment. Install the hose for the actuator. Be sure that the hose is not kinked. Be sure that the hose does not rub at any point. Continue with an alternate diagnosis.The Actuation Calibration Reading is Below 103 kPa (15 psi)
The turbine housing must be replaced if the actuation calibration reading is below 103 kPa (15 psi). Remove the test hose and all test equipment and replace the turbine housing. Refer to Disassembly and Assembly, "Turbocharger - Disassemble" and Disassembly and Assembly, "Turbocharger - Assemble".The Actuation Calibration Reading is Between 103 kPa (15 psi) and 128 kPa (18.5 psi)
The actuator must be replaced and recalibrated if the actuation calibration reading is between 128 kPa (18.5 psi) and 103 kPa (15 psi). Replace the wastegate actuator with a 225-0319 Actuator Kit. Refer to "Installation and Calibration of a New Wastegate Actuator".Installation and Calibration of a New Wastegate Actuator
Use the following procedures in order to install a 225-0319 Actuator Kit and calibrate the new wastegate actuator.
Illustration 4 g00918562
Apply 138 kPa (20 psi) of air pressure to the actuator (3). Remove the clip (5) from the crank pin. Discard the clip (5) .
Reduce the air pressure to 0 kPa (0 psi) and remove the test hose (H) from the actuator (3) .
Illustration 5 g00918611
Note the orientation of the hose nipple (6) on the actuator (3). Remove the nuts (7) that fasten the actuator to the bracket and remove the actuator. Do not remove the bracket.
Illustration 6 g00918624
(8) New actuator (9) Nut (10) Jam nut (11) Rod end (12) Clip
Illustration 7 g00918625
(X) Same length as the old actuator
Refer to Illustration 6 and Illustration 7. Assemble the new actuator (8), jam nut (10), and rod end (11) that is included in the 225-0319 Actuator Kit .


Parts cap Mercury:

26852
 
26852 CAP, NYLON - ADJUSTING SCREW
1035204, 1035207, 1040200, 1040208, 111047JHD, 1115473WD, 11354120D, 1135412GD, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1135473UD, 1135473VD, 1135473YD, 1135726, 1135D73CD, 1135D73FT, 1150413CD, 1150413FY, 1150413HF, 1150413HY, 1150413SD, 1150413
48416
 
48416 CAP, STEERING HANDLE GRIP
1035204, 1035207, 1040200, 10402139D, 1045217, 1050200, 1050302SD, 1050312LD, 1055207DB, 1055207UD, 1055207VB, 1070312BC, 1070717, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 10754120D, 1075412DB, 1075412DD
810779
CAP
810779 CAP
11354120D, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1150453JD, 1225412PD, 1225412VD
822401
CAP-TILT STOP PIN
822401 CAP-TILT STOP PIN
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1040213YL, 1041312UB, 10432037D, 1043203VD, 1F25201UD, 1F25203VD, 1F50412RD
814449A 3
CAP ASSEMBLY
814449A 3 CAP ASSEMBLY
1200453CD, 1200453EY, 1200453HY, 1200473TD, 1200473UD, 1200473VD, 1200473WD, 1200473YD, 1225412PD, 1225412VD, 1225413EY, 1225413RD, 1225413ZD, 1225423EY, 1225424EY, 1250413CD, 1250413UE, 1250424EY, 1250433EY, 1250434EY, 1256413WD
853745
CAP
853745 CAP
1006201AK, 1006201FK, 1008201YM, 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1040203FL, 1040203YL, 1040213YL, 1A25203FK, 1A25203F
853825
CAP
853825 CAP
1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1040203FL, 1040203YL, 1040213YL, 1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413K
822447T01
CAP ASSEMBLY, Connector - 3 Pin Male
822447T01 CAP ASSEMBLY, Connector - 3 Pin Male
1075D73FY, 1075D73HY, 1115P73HY, 1115P73HY, 1125D73HY, 192647GHD, 192847GHD, 1A40302FD, 1A40302HZ, 1A40303KZ, 1A40311FZ, 1A40311HZ, 1A40403HZ, 1A40412HZ
Back to top